diff --git a/SCADA_IoT_Energy_Home_Automation_Industrial_monitoring/template_tx_hitachi_ec704mp/6.0/README.md b/SCADA_IoT_Energy_Home_Automation_Industrial_monitoring/template_tx_hitachi_ec704mp/6.0/README.md index 60be14404..9e4d7629b 100644 --- a/SCADA_IoT_Energy_Home_Automation_Industrial_monitoring/template_tx_hitachi_ec704mp/6.0/README.md +++ b/SCADA_IoT_Energy_Home_Automation_Industrial_monitoring/template_tx_hitachi_ec704mp/6.0/README.md @@ -26,14 +26,9 @@ Our applications have itens of the component below: * Template module ICMP Ping:status * System - - - - - ## Author -Marcos Sousa +Marcos Sousa and Tadeu Ibns ## Macros used @@ -117,4 +112,3 @@ There are no discovery rules in this template. ## Triggers There are no triggers in this template. - diff --git a/SCADA_IoT_Energy_Home_Automation_Industrial_monitoring/template_tx_hitachi_ec708hp_bb/6.0/README.md b/SCADA_IoT_Energy_Home_Automation_Industrial_monitoring/template_tx_hitachi_ec708hp_bb/6.0/README.md new file mode 100644 index 000000000..51567b5c2 --- /dev/null +++ b/SCADA_IoT_Energy_Home_Automation_Industrial_monitoring/template_tx_hitachi_ec708hp_bb/6.0/README.md @@ -0,0 +1,81 @@ +# tx Hitachi EC708HP-BB + +## Description + +Template of transmitter Hitachi model EC708HP-BB. + +## Overview + +Template of transmitter Hitachi model **EC708HP-BB.** This template contains: + + +* 6 applications +* 19 itens +* 5 triggers + + +Our applications have itens of the component below: + + +* Energy +* Forward Power +* Multiplexer +* PSU +* System +* Temperature + +## Author + +Marcos Sousa and Tadeu Ibns + +## Macros used + +* $PERCENTUAL_POWER_AVAILABLE: Rate of available the power of equipament - default (0.2 -> 20%) +* $PERCENTUAL_REFLECTED_HIGH: Rate of available the reflected power of equipment - default (0.2 -> 20%) for high triggers +* $PERCENTUAL_REFLECTED_WARNING: Rate of available the reflected power of equipment - default (0.15 -> 15%) for warning triggers +* $PROGRAMMED_POWER: Power programmed of the equipament + +## Template links + +There aren't template links in this template. + + +## Discovery rules + +There are no discovery rules in this template. + +## Items collected + +|Name|Description|Type|Key and additional info| +|----|-----------|----|----| +|System - ALC Refence (V)|
System - ALC Refence (V) systemALCRefenceVoltage.0
|`SNMP agent`|systemALCRefenceVoltage.0Update: 1m
| +|System - Forward Power|System Forward Power [W] systemForwardPower.0
|`SNMP agent`|systemForwardPower.0Update: 15s
| +|System - Multiplexer 1PPS Input|System - Multiplexer 1PPS InputmultiplexerSfn1PPsInput. 0 Status of the 1 Pulse Per Second (1PPS) reference for the internal time base. SYNTAX INTEGER { notpresent(0), present(1)..
|`SNMP agent`|multiplexerSfn1PPsInput.0Update: 1m
| +|System - Multiplexer BTS Alignment|Indicates BTS Alignment. When TSP and Clock alignment is achieved, it means that the equipment is perfectly synchronized with the Network. When just TSP alignment is informed, it means that synchronization still holds but slight jitter (wander) is present (generally due to momentary lost of time base reference). SYNTAX INTEGER { none(0), tsp(1), clk(2), tspclk(3) }
|`SNMP agent`|multiplexerSfnBTSAlignment.0Update: 1m
| +|System - Multiplexer SFN Info|Status of the SFN information (NSI) in the IIP within the BTS. SYNTAX INTEGER { notpresent(0), present(1) }
|`SNMP agent`|multiplexerSfnInfo.0Update: 1m
| +|System - Power Amplifier 1 Current|System - Power Amplifier 1 Current power1PA1Current.0.
|`SNMP agent`|power1PA1Current.0Update: 1m
| +|System - Power Amplifier 2 Current|System - Power Amplifier 2 Current power1PA2Current.0.
|`SNMP agent`|power1PA2Current.0Update: 1m
| +|System - Programmed Power|System Programmed Power [W] systemProgrammedPower.0.
|`SNMP agent`|systemProgrammedPower.0Update: 1h
| +|System - PSU1 Output (50V)|System - PSU1 Output (50V) power1PSU1PowerSupply50V.0 Mesurement of the +50V Power Supply 1 output. (Apply Mask 0,0)
|`SNMP agent`| power1PSU1PowerSupply50V.0Update: 1m
| +|System - PSU1 Output Current|System - PSU1 Output Current power1PSU1PowerSupplyCurrent.0 System - PSU1 Output Current Mesurement of the Power Supply 1 total current consumption.
|`SNMP agent`|power1PSU1PowerSupplyCurrent.0Update: 1m
| +|System - PSU2 Output Current|System - PSU1 Voltage power1PSU1ACLineVoltage.0.
|`SNMP agent`|power1PSU1ACLineVoltage.0Update: 1m
| +|System - PSU1 Voltage|System - PSU1 Voltage power1PSU1ACLineVoltage.0.
|`SNMP agent`|power1PSU1ACLineVoltage.0Update: 1m
| +|System - PSU2 Voltage|System - PSU2 Voltage power1PSU2ACLineVoltage.0 System - PSU2 Voltage Measurement of the Power Supply 2 Input Voltage.
|`SNMP agent`|power1PSU2ACLineVoltage.0Update: 1m
| +|System - Reflected Power|Measured of RF total reflected power at mask filter output.(Apply Mask 0,00).
|`SNMP agent`| systemReflectedPower.0Update: 15s
| +|System - Reflectometer (V)|System - Reflectometer (V) systemReflectometerVoltage.0
|`SNMP agent`| systemReflectometerVoltage.0Update: 1m
| +|System - Uptime|System Uptime
|`SNMP agent`|sysUpTime.0Update: 1h
| +|Temperature - Power Amplifier |Measurement of the Power Supply 1 Temperature (Celcius).
|`SNMP agent`|exciterPower1SupplyTemperature.0Update: 5m
| +|Temperature - PSU1|Temperature - PSU1 power1PSU1Temperature.0 Measurement of the Power Supply 1 Temperature (Celcius).
|`SNMP agent`|power1PSU1Temperature.0Update: 5m
| +|Temperature - PSU2|Temperature - PSU2 power1PSU2Temperature.0 Measurement of the Power Supply 2 Temperature (Celcius).
|`SNMP agent`|power1PSU2Temperature.0Update: 5m
| + + + +## Triggers + +|Severity|Name|Expression| +|----|-----------|----| +| High |{HOST.NAME} - Forward Power - Low
| last(/Template TX Hitachi EC708HP-BB/systemForwardPower.0)<=({$PROGRAMMED_POWER} - ({$PROGRAMMED_POWER} * {$PERCENTUAL_POWER_AVAILABLE})) +|Information |{HOST.NAME} - Forward Power - Nodata (5m)
| nodata(/Template TX Hitachi EC708HP-BB/systemForwardPower.0,5m)=1 | +|Warning |{HOST.NAME} - Reflected Power >= 15%
|last(/Template TX Hitachi EC708HP-BB/systemReflectedPower.0)>=({$PROGRAMMED_POWER} * {$PERCENTUAL_REFLECTED_WARNING}) | +| High |{HOST.NAME} - Reflected Power >= 20%
| last(/Template TX Hitachi EC708HP-BB/systemReflectedPower.0)>=({$PROGRAMMED_POWER} * {$PERCENTUAL_REFLECTED_HIGH})| +| Warning |{HOST.NAME} No data - without data collected for more 24h
|nodata(/Template TX Hitachi EC708HP-BB/systemForwardPower.0,24h)=1| \ No newline at end of file diff --git a/SCADA_IoT_Energy_Home_Automation_Industrial_monitoring/template_tx_hitachi_ec708hp_bb/6.0/template_tx_hitachi_ec708hp_bb.yaml b/SCADA_IoT_Energy_Home_Automation_Industrial_monitoring/template_tx_hitachi_ec708hp_bb/6.0/template_tx_hitachi_ec708hp_bb.yaml new file mode 100644 index 000000000..8324fd9f9 --- /dev/null +++ b/SCADA_IoT_Energy_Home_Automation_Industrial_monitoring/template_tx_hitachi_ec708hp_bb/6.0/template_tx_hitachi_ec708hp_bb.yaml @@ -0,0 +1,737 @@ +zabbix_export: + version: '6.0' + date: '2022-12-30T18:06:08Z' + groups: + - + uuid: c377e771fd364578a753b1f1f64d3cbd + name: Templates/Transmitters + templates: + - + uuid: 15a4a29a58f04c6aac894e78b5f22651 + template: 'Template TX Hitachi EC708HP-BB' + name: 'Template TX Hitachi EC708HP-BB' + description: | + Template of transmitter Hitachi model EC708HP-BB. + groups: + - + name: Templates/Transmitters + items: + - + uuid: 2b2b2e587db54f60bc76de345b7bf6b9 + name: 'System - Multiplexer 1PPS Input' + type: SNMP_AGENT + snmp_oid: .1.3.6.1.4.1.25026.13.1.2.15.0 + key: multiplexerSfn1PPsInput.0 + history: 180d + trends: '0' + value_type: TEXT + description: | + System - Multiplexer 1PPS Input + multiplexerSfn1PPsInput.0 + + Status of the 1 Pulse Per Second (1PPS) reference for the internal time base. + SYNTAX INTEGER { notpresent(0), present(1). + preprocessing: + - + type: STR_REPLACE + parameters: + - '0' + - 'Not Present' + - + type: STR_REPLACE + parameters: + - '1' + - Error + - + type: STR_REPLACE + parameters: + - '2' + - Present + tags: + - + tag: Application + value: Multiplexer + - + uuid: c413aa8274844ebf848357e1337e969c + name: 'System - Multiplexer BTS Alignment' + type: SNMP_AGENT + snmp_oid: .1.3.6.1.4.1.25026.13.1.2.16.0 + key: multiplexerSfnBTSAlignment.0 + history: 180d + trends: '0' + value_type: TEXT + description: | + System - Multiplexer BTS Alignment + multiplexerSfnBTSAlignment.0 + + Indicates BTS Alignment. When TSP and Clock alignment is achieved, it means that the equipment is perfectly synchronized with the Network. When just TSP alignment is informed, it means that synchronization still holds but slight jitter (wander) is present (generally due to momentary lost of time base reference). + SYNTAX INTEGER { none(0), tsp(1), clk(2), tspclk(3) } + preprocessing: + - + type: STR_REPLACE + parameters: + - '0' + - None + - + type: STR_REPLACE + parameters: + - '1' + - CLK + - + type: STR_REPLACE + parameters: + - '2' + - TSP + - + type: STR_REPLACE + parameters: + - '3' + - 'TSP & CLK' + tags: + - + tag: Application + value: Multiplexer + - + uuid: 81e76f494fc74757a424af6f3415cf27 + name: 'System - Multiplexer SFN Info' + type: SNMP_AGENT + snmp_oid: .1.3.6.1.4.1.25026.13.1.2.17.0 + key: multiplexerSfnInfo.0 + history: 180d + trends: '0' + value_type: TEXT + description: | + System - Multiplexer SFN Info + multiplexerSfnInfo.0 + + Status of the SFN information (NSI) in the IIP within the BTS. + SYNTAX INTEGER { notpresent(0), present(1) } + preprocessing: + - + type: STR_REPLACE + parameters: + - '0' + - 'Off' + - + type: STR_REPLACE + parameters: + - '1' + - Error + - + type: REGEX + parameters: + - '2' + - 'On' + tags: + - + tag: Application + value: Multiplexer + - + uuid: 9124798f142c4873b08a64320d482094 + name: 'System - Power Amplifier 1 Current' + type: SNMP_AGENT + snmp_oid: .1.3.6.1.4.1.25026.13.1.11.25.0 + key: power1PA1Current.0 + history: 180d + value_type: FLOAT + units: A + description: | + System - Power Amplifier 1 Current + power1PA1Current.0 + preprocessing: + - + type: MULTIPLIER + parameters: + - '0.01' + tags: + - + tag: Application + value: Energy + - + tag: Application + value: System + - + uuid: 8642dd3be49041f19842e9a14e45340f + name: 'System - Power Amplifier 2 Current' + type: SNMP_AGENT + snmp_oid: .1.3.6.1.4.1.25026.13.1.11.29.0 + key: power1PA2Current.0 + history: 180d + value_type: FLOAT + units: A + description: | + System - Power Amplifier 2 Current + power1PA2Current.0 + preprocessing: + - + type: MULTIPLIER + parameters: + - '0.01' + tags: + - + tag: Application + value: Energy + - + tag: Application + value: System + - + uuid: 5f4fa5e75f844ff4ae1dbd6d6173784c + name: 'System - PSU1 Voltage' + type: SNMP_AGENT + snmp_oid: .1.3.6.1.4.1.25026.13.1.11.1.0 + key: power1PSU1ACLineVoltage.0 + history: 180d + value_type: FLOAT + units: V + description: | + System - PSU1 Voltage + power1PSU1ACLineVoltage.0 + preprocessing: + - + type: MULTIPLIER + parameters: + - '0.1' + tags: + - + tag: Application + value: Energy + - + tag: Application + value: System + - + uuid: 70cb831fb7434532b6cbc5e0a4a9e5be + name: 'System - PSU1 Output (50V)' + type: SNMP_AGENT + snmp_oid: .1.3.6.1.4.1.25026.13.1.11.2.0 + key: power1PSU1PowerSupply50V.0 + history: 180d + value_type: FLOAT + units: V + description: | + System - PSU1 Output (50V) + power1PSU1PowerSupply50V.0 + + Mesurement of the +50V Power Supply 1 output.(Apply Mask 0,0) + preprocessing: + - + type: MULTIPLIER + parameters: + - '0.1' + tags: + - + tag: Application + value: Energy + - + tag: Application + value: System + - + uuid: 7b77bf5b2ffc4876b5b56410285ef4c6 + name: 'System - PSU1 Output Current' + type: SNMP_AGENT + snmp_oid: .1.3.6.1.4.1.25026.13.1.11.3.0 + key: power1PSU1PowerSupplyCurrent.0 + history: 180d + value_type: FLOAT + units: A + description: | + System - PSU1 Output Current + power1PSU1PowerSupplyCurrent.0 + + System - PSU1 Output Current + Mesurement of the Power Supply 1 total current consumption. + preprocessing: + - + type: MULTIPLIER + parameters: + - '0.01' + tags: + - + tag: Application + value: Energy + - + tag: Application + value: System + - + uuid: d76eaf1af1ad4056aaa3c89a28fbea78 + name: 'Temperature - PSU1' + type: SNMP_AGENT + snmp_oid: .1.3.6.1.4.1.25026.13.1.11.4.0 + key: power1PSU1Temperature.0 + delay: 5m + history: 180d + value_type: FLOAT + units: '° C' + description: | + Temperature - PSU1 + power1PSU1Temperature.0 + + Measurement of the Power Supply 1 Temperature (Celcius). + preprocessing: + - + type: MULTIPLIER + parameters: + - '0.1' + - + type: JAVASCRIPT + parameters: + - 'return (value - 32) /2' + tags: + - + tag: Application + value: PSU + - + tag: Application + value: Temperature + - + uuid: cde3f2758c614b0fb5ca75c8a60db28c + name: 'System - PSU2 Voltage' + type: SNMP_AGENT + snmp_oid: .1.3.6.1.4.1.25026.13.1.11.8.0 + key: power1PSU2ACLineVoltage.0 + history: 180d + value_type: FLOAT + units: V + description: | + System - PSU2 Voltage + power1PSU2ACLineVoltage.0 + + System - PSU2 Voltage + Measurement of the Power Supply 2 Input Voltage. + preprocessing: + - + type: MULTIPLIER + parameters: + - '0.1' + tags: + - + tag: Application + value: Energy + - + tag: Application + value: System + - + uuid: ffa06bd6611f4da48c34e5fd3330a2ed + name: 'System - PSU2 Output (50V)' + type: SNMP_AGENT + snmp_oid: .1.3.6.1.4.1.25026.13.1.11.9.0 + key: power1PSU2PowerSupply50V.0 + history: 180d + value_type: FLOAT + units: V + description: | + System - PSU2 Output (50V) + power1PSU2PowerSupply50V.0 + + System - PSU2 Output (50V) + Mesurement of the +50V Power Supply 1 output.(Apply Mask 0,0) + preprocessing: + - + type: MULTIPLIER + parameters: + - '0.1' + tags: + - + tag: Application + value: Energy + - + tag: Application + value: System + - + uuid: 32695e57835046b48279b00969051ffe + name: 'System - PSU2 Output Current' + type: SNMP_AGENT + snmp_oid: .1.3.6.1.4.1.25026.13.1.11.10.0 + key: power1PSU2PowerSupplyCurrent.0 + history: 180d + value_type: FLOAT + units: A + description: | + System - PSU2 Output Current + power1PSU2PowerSupplyCurrent.0 + + System - PSU2 Output Current + Mesurement of the Power Supply 2 total current consumption. + preprocessing: + - + type: MULTIPLIER + parameters: + - '0.01' + tags: + - + tag: Application + value: Energy + - + tag: Application + value: System + - + uuid: 0c532b16ff464ee19f253409834c3d4e + name: 'Temperature - PSU2' + type: SNMP_AGENT + snmp_oid: .1.3.6.1.4.1.25026.13.1.11.11.0 + key: power1PSU2Temperature.0 + delay: 5m + history: 180d + value_type: FLOAT + units: '° C' + description: | + Temperature - PSU2 + power1PSU2Temperature.0 + + Measurement of the Power Supply 2 Temperature (Celcius). + preprocessing: + - + type: MULTIPLIER + parameters: + - '0.1' + - + type: JAVASCRIPT + parameters: + - 'return (value - 32) /2' + tags: + - + tag: Application + value: PSU + - + tag: Application + value: Temperature + - + uuid: b73f95cf03b74db3bf0d5a141d480774 + name: 'System - ALC Refence (V)' + type: SNMP_AGENT + snmp_oid: .1.3.6.1.4.1.25026.13.1.1.11.0 + key: systemALCRefenceVoltage.0 + history: 180d + value_type: FLOAT + units: V + description: | + System - ALC Refence (V) + systemALCRefenceVoltage.0 + preprocessing: + - + type: MULTIPLIER + parameters: + - '0.01' + tags: + - + tag: Application + value: Energy + - + tag: Application + value: System + - + uuid: 3ad507b7b1a54fc5b303b3d090daea30 + name: 'System - Forward Power' + type: SNMP_AGENT + snmp_oid: .1.3.6.1.4.1.25026.13.1.1.9.0 + key: systemForwardPower.0 + delay: 15s + history: 180d + value_type: FLOAT + units: W + description: | + System Forward Power [W] + systemForwardPower.0 + tags: + - + tag: Application + value: 'Forward Power' + - + tag: Application + value: System + triggers: + - + uuid: 56dba76abe0745bfb821139b70a7f5a1 + expression: 'last(/Template TX Hitachi EC708HP-BB/systemForwardPower.0)<=({$PROGRAMMED_POWER} - ({$PROGRAMMED_POWER} * {$PERCENTUAL_POWER_AVAILABLE}))' + name: '{HOST.NAME} - Forward Power - Low' + priority: HIGH + description: 'Trigger of Forward Power Low.' + manual_close: 'YES' + - + uuid: dfaef44fa4e9400793aa314cfc1e6bf4 + expression: 'nodata(/Template TX Hitachi EC708HP-BB/systemForwardPower.0,5m)=1' + name: '{HOST.NAME} - Forward Power - Nodata (5m)' + priority: INFO + description: 'Nodata of Trigger of Forward Power.' + manual_close: 'YES' + - + uuid: 2477c5f6c37947b1a4b876738d92aeeb + expression: 'nodata(/Template TX Hitachi EC708HP-BB/systemForwardPower.0,24h)=1' + name: '{HOST.NAME} No data - without data collected for more 24h' + status: DISABLED + priority: WARNING + manual_close: 'YES' + - + uuid: b2fec9dee8b140e48f8918b5b78d43e3 + name: 'System - Programmed Power' + type: SNMP_AGENT + snmp_oid: .1.3.6.1.4.1.25026.13.1.1.8.0 + key: systemProgrammedPower.0 + delay: 1h + history: 180d + value_type: FLOAT + units: W + description: | + System Programmed Power [W] + systemProgrammedPower.0 + preprocessing: + - + type: JAVASCRIPT + parameters: + - 'return $PROGRAMMED_POWER = value;' + tags: + - + tag: Application + value: 'Forward Power' + - + tag: Application + value: System + - + uuid: 685c7869a56a46348be2247be7e1a1a1 + name: 'System - Reflected Power' + type: SNMP_AGENT + snmp_oid: .1.3.6.1.4.1.25026.13.1.1.10.0 + key: systemReflectedPower.0 + delay: 15s + history: 180d + value_type: FLOAT + units: W + description: | + System - Reflected Power + systemReflectedPower.0 + + Measured of RF total reflected power at mask filter output.(Apply Mask 0,00). + tags: + - + tag: Application + value: 'Forward Power' + - + tag: Application + value: System + triggers: + - + uuid: be24c62ea30d475b9b02bc645e5ae8ab + expression: 'last(/Template TX Hitachi EC708HP-BB/systemReflectedPower.0)>=({$PROGRAMMED_POWER} * {$PERCENTUAL_REFLECTED_WARNING})' + name: '{HOST.NAME} - Reflected Power >= 15%' + priority: WARNING + description: 'Reflected Power >= 15%' + manual_close: 'YES' + - + uuid: d081fcd1bac34c019e26ecea83433184 + expression: 'last(/Template TX Hitachi EC708HP-BB/systemReflectedPower.0)>=({$PROGRAMMED_POWER} * {$PERCENTUAL_REFLECTED_HIGH})' + name: '{HOST.NAME} - Reflected Power >= 20%' + priority: HIGH + description: 'Reflected Power >= 20%' + manual_close: 'YES' + - + uuid: b078e1719d7240c6809e0e7f4ffe8adf + name: 'System - Reflectometer (V)' + type: SNMP_AGENT + snmp_oid: .1.3.6.1.4.1.25026.13.1.1.12.0 + key: systemReflectometerVoltage.0 + history: 180d + value_type: FLOAT + units: V + description: | + System - Reflectometer (V) + reflectedPowerSensorVoltage.0 + preprocessing: + - + type: MULTIPLIER + parameters: + - '0.01' + tags: + - + tag: Application + value: Energy + - + tag: Application + value: System + - + uuid: 3c64dc3aa7b5497f83c8d7c1fa9c58aa + name: 'System - Uptime' + type: SNMP_AGENT + snmp_oid: .1.3.6.1.2.1.1.3.0 + key: sysUpTime.0 + delay: 1h + history: 180d + units: uptime + description: 'System Uptime' + preprocessing: + - + type: MULTIPLIER + parameters: + - '0.01' + tags: + - + tag: Application + value: System + macros: + - + macro: '{$PERCENTUAL_POWER_AVAILABLE}' + value: '0.20' + description: 'Rate of available the power of equipamment - default (0.2 -> 20%)' + - + macro: '{$PERCENTUAL_REFLECTED_HIGH}' + value: '0.20' + description: 'Rate of available the reflected power of equipment - default (0.2 -> 20%) for high triggers' + - + macro: '{$PERCENTUAL_REFLECTED_WARNING}' + value: '0.15' + description: 'Rate of available the reflected power of equipment - default (0.15 -> 15%) for warning triggers' + - + macro: '{$PROGRAMMED_POWER}' + value: '0' + description: 'Power programmed of the equipament' + graphs: + - + uuid: 7e8fa5f9f1894c34a60a0e8980ffdc8d + name: 'Power Amplifier - Current' + show_work_period: 'NO' + graph_items: + - + color: 1A7C11 + calc_fnc: ALL + item: + host: 'Template TX Hitachi EC708HP-BB' + key: power1PA1Current.0 + - + sortorder: '1' + color: F63100 + calc_fnc: ALL + item: + host: 'Template TX Hitachi EC708HP-BB' + key: power1PA2Current.0 + - + uuid: 6ecfbb10e71445a19083be7ae1d3f400 + name: 'Power Supply - Current' + show_work_period: 'NO' + graph_items: + - + color: 1A7C11 + calc_fnc: ALL + item: + host: 'Template TX Hitachi EC708HP-BB' + key: power1PSU1PowerSupplyCurrent.0 + - + sortorder: '1' + color: F63100 + calc_fnc: ALL + item: + host: 'Template TX Hitachi EC708HP-BB' + key: power1PSU2PowerSupplyCurrent.0 + - + uuid: 6956c9f9c0b549678503d103910fd80b + name: 'Power Supply - Voltage (50V)' + show_work_period: 'NO' + graph_items: + - + color: 1A7C11 + calc_fnc: ALL + item: + host: 'Template TX Hitachi EC708HP-BB' + key: power1PSU1PowerSupply50V.0 + - + sortorder: '1' + color: F63100 + calc_fnc: ALL + item: + host: 'Template TX Hitachi EC708HP-BB' + key: power1PSU2PowerSupply50V.0 + - + uuid: 27ab2e20aa33428d93258ad1358ebae9 + name: 'Power Supply - Voltages' + show_work_period: 'NO' + graph_items: + - + color: 1A7C11 + calc_fnc: ALL + item: + host: 'Template TX Hitachi EC708HP-BB' + key: power1PSU1ACLineVoltage.0 + - + sortorder: '1' + color: F63100 + calc_fnc: ALL + item: + host: 'Template TX Hitachi EC708HP-BB' + key: power1PSU2ACLineVoltage.0 + - + uuid: 3018649745ac4d20b6542e6e19f7c17d + name: 'System - Forward Data' + show_work_period: 'NO' + graph_items: + - + color: 1A7C11 + calc_fnc: ALL + item: + host: 'Template TX Hitachi EC708HP-BB' + key: systemForwardPower.0 + - + sortorder: '1' + color: F63100 + calc_fnc: ALL + item: + host: 'Template TX Hitachi EC708HP-BB' + key: systemALCRefenceVoltage.0 + - + sortorder: '2' + color: 2774A4 + calc_fnc: ALL + item: + host: 'Template TX Hitachi EC708HP-BB' + key: systemProgrammedPower.0 + - + sortorder: '3' + color: A54F10 + calc_fnc: ALL + item: + host: 'Template TX Hitachi EC708HP-BB' + key: systemReflectedPower.0 + - + sortorder: '4' + color: FC6EA3 + calc_fnc: ALL + item: + host: 'Template TX Hitachi EC708HP-BB' + key: systemReflectometerVoltage.0 + - + uuid: 6f7cc0367e8949cc9abd41b3ef46d2b4 + name: 'System - Forward Power' + show_work_period: 'NO' + graph_items: + - + drawtype: FILLED_REGION + color: 1A7C11 + calc_fnc: ALL + item: + host: 'Template TX Hitachi EC708HP-BB' + key: systemForwardPower.0 + - + uuid: d943400677ba4931aa2194617594ac25 + name: 'System - Temperature' + show_work_period: 'NO' + graph_items: + - + color: 1A7C11 + calc_fnc: ALL + item: + host: 'Template TX Hitachi EC708HP-BB' + key: power1PSU1Temperature.0 + - + sortorder: '1' + color: F63100 + calc_fnc: ALL + item: + host: 'Template TX Hitachi EC708HP-BB' + key: power1PSU2Temperature.0 + - + uuid: d67d64d2e70343e692f31f02b3664afe + name: 'System - Uptime' + show_work_period: 'NO' + graph_items: + - + color: 1A7C11 + calc_fnc: ALL + item: + host: 'Template TX Hitachi EC708HP-BB' + key: sysUpTime.0 diff --git a/SCADA_IoT_Energy_Home_Automation_Industrial_monitoring/template_tx_hitachi_ec_701lp/6.0/README.md b/SCADA_IoT_Energy_Home_Automation_Industrial_monitoring/template_tx_hitachi_ec_701lp/6.0/README.md new file mode 100644 index 000000000..4f4c04b8e --- /dev/null +++ b/SCADA_IoT_Energy_Home_Automation_Industrial_monitoring/template_tx_hitachi_ec_701lp/6.0/README.md @@ -0,0 +1,82 @@ +# tx Hitachi EC701LP + +## Description + +Template of transmitter Hitachi model EC701LP. + +## Overview + +Template of transmitter Hitachi model **EC701LP.** This template contains: + + +* 7 applications +* 18 itens +* 5 triggers + + +Our applications have itens of the component below: + + +* Energy +* Forward Power +* Multiplexer +* Power Amplifier +* PSU +* System +* Temperature + +## Author + +Marcos Sousa and Tadeu Ibns + +## Macros used + +* $PERCENTUAL_POWER_AVAILABLE: Rate of available the power of equipament - default (0.2 -> 20%) +* $PERCENTUAL_REFLECTED_HIGH: Rate of available the reflected power of equipment - default (0.2 -> 20%) for high triggers +* $PERCENTUAL_REFLECTED_WARNING: Rate of available the reflected power of equipment - default (0.15 -> 15%) for warning triggers +* $PROGRAMMED_POWER: Power programmed of the equipament + +## Template links + +There aren't template links in this template. + + +## Discovery rules + +There are no discovery rules in this template. + +## Items collected + +|Name|Description|Type|Key and additional info| +|----|-----------|----|----| +|System - ALC Refence (V)|System - ALC Refence (V) alcVoltage.0
|`SNMP agent`|alcVoltage.0Update: 1m
| +|System - Forward Power|System - Forward Power forwardPower.0
|`SNMP agent`|forwardPower.0Update: 15s
| +|System - Multiplexer 1PPS Input|Status of the 1 Pulse Per Second (1PPS) reference for the internal time base. SYNTAX INTEGER { notpresent(0), present(1).
|`SNMP agent`|ppsInput.0Update: 1m
| +|PA3 Current|Measure of Power Amplifier for item power1PA3Current
|`SNMP agent`|power1PA3.currentUpdate: 1m
| +|System - Multiplexer BTS Alignment|Indicates BTS Alignment. When TSP and Clock alignment is achieved, it means that the equipment is perfectly synchronized with the Network. When just TSP alignment is informed, it means that synchronization still holds but slight jitter (wander) is present (generally due to momentary lost of time base reference). SYNTAX INTEGER { none(0), tsp(1), clk(2), tspclk(3) }
|`SNMP agent`|btsAlignment.0Update: 1m
| +|System - Multiplexer SFN Info|Status of the SFN information (NSI) in the IIP within the BTS. SYNTAX INTEGER { notpresent(0), present(1) }
|`SNMP agent`|sfnInfo.0Update: 1m
| +|System - Power Amplifier Current|System - Power Amplifier Current Power Amplifier Current.
|`SNMP agent`|paCurrent.0Update: 1m
| +|System - PSU1 Output (50V)|System - PSU1 Output (50V) exciterPower1Supply50v.0.
|`SNMP agent`|exciterPower1Supply50v.0Update: 1m
| +|System - PSU1 Output Current|System - PSU1 Output Current Mesurement of the Power Supply 1 total current consumption.
|`SNMP agent`|exciterPower1SupplyCurrent.0Update: 1m
| +|System - PSU1 Voltage|System - PSU1 Voltage power1PSU1ACLineVoltage.0
|`SNMP agent`|exciterPower1SupplyAc.0Update: 1m
| +|System - PSU2 Output (50V)|System - PSU2 Output (50V) Mesurement of the +50V Power Supply 1 output.(Apply Mask 0,0).
|`SNMP agent`|exciterPower2Supply50v.0Update: 1m
| +|System - PSU2 Output Current|System - PSU2 Output Current Mesurement of the Power Supply 2 total current consumption.
|`SNMP agent`|power1PSU2PowerSupplyCurrent.0Update: 1m
| +|System - PSU2 Voltage|System - PSU2 Voltage Measurement of the Power Supply 2 Input Voltage.
|`SNMP agent`|exciterPower2SupplyAc.0Update: 1m
| +|System - Reflected Power|Measured of RF total reflected power at mask filter output.(Apply Mask 0,00).
|`SNMP agent`|reflectedPower.0Update: 1m
| +|System - Reflectometer (V)|System - Reflectometer (V) reflectedPowerSensorVoltage.0
|`SNMP agent`|power1PA1.temperatureUpdate: 1m
| +|System - Uptime|System Uptime
|`SNMP agent`|sysUpTime.0Update: 1h
| +|Temperature - Power Amplifier |Measurement of the Power Supply 1 Temperature (Celcius).
|`SNMP agent`|exciterPower1SupplyTemperature.0Update: 5m
| +|Temperature - PSU1|Measure of Input Air Temperature for power1FAN1Rotation.
|`SNMP agent`|power1.fan1.rotationUpdate: 1m
| +|Temperature - PSU2|Measurement of the Power Supply 2 Temperature (Celcius).
|`SNMP agent`|exciterPower2SupplyTemperature.0Update: 5m
| + + + +## Triggers + +|Severity|Name|Expression| +|----|-----------|----| +| High |{HOST.NAME} - Forward Power - Low
| last(/Template TX Hitachi EC7X0LP/forwardPower.0)<=({$PROGRAMMED_POWER} - ({$PROGRAMMED_POWER} * {$PERCENTUAL_POWER_AVAILABLE})) +|Information |{HOST.NAME} - Forward Power - Nodata (5m)
| nodata(/Template TX Hitachi EC7X0LP/forwardPower.0,5m)=1 | +|Warning |{HOST.NAME} - Reflected Power >= 15%
| last(/Template TX Hitachi EC7X0LP/reflectedPower.0)>=({$PROGRAMMED_POWER} * {$PERCENTUAL_REFLECTED_WARNING}) {HOST.NAME} - Reflected Power >= 15% | +| High |{HOST.NAME} - Reflected Power >= 20%
| last(/Template TX Hitachi EC7X0LP/reflectedPower.0)>=({$PROGRAMMED_POWER} * {$PERCENTUAL_REFLECTED_HIGH})| +| Warning |{HOST.NAME} No data - without data collected for more 24h
| nodata(/Template TX Hitachi EC7X0LP/forwardPower.0,24h)=1| \ No newline at end of file diff --git a/SCADA_IoT_Energy_Home_Automation_Industrial_monitoring/template_tx_hitachi_ec_701lp/6.0/template_tx_hitachi_ec_701lp.yaml b/SCADA_IoT_Energy_Home_Automation_Industrial_monitoring/template_tx_hitachi_ec_701lp/6.0/template_tx_hitachi_ec_701lp.yaml new file mode 100644 index 000000000..f5feba521 --- /dev/null +++ b/SCADA_IoT_Energy_Home_Automation_Industrial_monitoring/template_tx_hitachi_ec_701lp/6.0/template_tx_hitachi_ec_701lp.yaml @@ -0,0 +1,660 @@ +zabbix_export: + version: '6.0' + date: '2022-12-30T17:03:29Z' + groups: + - + uuid: c377e771fd364578a753b1f1f64d3cbd + name: Templates/Transmitters + templates: + - + uuid: 0f151aaaf9794abca845ee1d274f8a3b + template: 'Template TX Hitachi EC7X0LP' + name: 'Template TX Hitachi EC7X0LP' + description: | + Template of transmitter Hitachi model EC710LP. + groups: + - + name: Templates/Transmitters + items: + - + uuid: 83cf214a897e401884a5ce25212b7b98 + name: 'System - ALC Refence (V)' + type: SNMP_AGENT + snmp_oid: .1.3.6.1.4.1.25026.7.1.2.1.6.0 + key: alcVoltage.0 + history: 180d + value_type: FLOAT + units: V + description: | + System - ALC Refence (V) + alcVoltage.0 + preprocessing: + - + type: MULTIPLIER + parameters: + - '0.01' + tags: + - + tag: Application + value: Energy + - + tag: Application + value: System + - + uuid: 25b991976e144ad390da6595b4615c74 + name: 'System - Multiplexer BTS Alignment' + type: SNMP_AGENT + snmp_oid: .1.3.6.1.4.1.25026.7.1.2.4.1.3.0 + key: btsAlignment.0 + history: 180d + trends: '0' + value_type: TEXT + description: | + Indicates BTS Alignment. When TSP and Clock alignment is achieved, it means that the equipment is perfectly synchronized with the Network. When just TSP alignment is informed, it means that synchronization still holds but slight jitter (wander) is present (generally due to momentary lost of time base reference). + SYNTAX INTEGER { none(0), tsp(1), clk(2), tspclk(3) } + preprocessing: + - + type: STR_REPLACE + parameters: + - '0' + - None + - + type: STR_REPLACE + parameters: + - '1' + - TSP + - + type: STR_REPLACE + parameters: + - '2' + - CLK + - + type: STR_REPLACE + parameters: + - '3' + - 'TSP & CLK' + tags: + - + tag: Application + value: Multiplexer + - + uuid: 50d9a733e22843449519e4b3aaaf81d7 + name: 'System - PSU1 Output (50V)' + type: SNMP_AGENT + snmp_oid: .1.3.6.1.4.1.25026.7.1.2.6.2.1.0 + key: exciterPower1Supply50v.0 + history: 180d + value_type: FLOAT + units: V + description: | + System - PSU1 Output (50V) + exciterPower1Supply50v.0 + preprocessing: + - + type: MULTIPLIER + parameters: + - '0.1' + tags: + - + tag: Application + value: Energy + - + tag: Application + value: System + - + uuid: dc1302b64f78446c91dc79d99e80e582 + name: 'System - PSU1 Voltage' + type: SNMP_AGENT + snmp_oid: .1.3.6.1.4.1.25026.7.1.2.6.2.3.0 + key: exciterPower1SupplyAc.0 + history: 180d + value_type: FLOAT + units: V + description: | + System - PSU1 Voltage + power1PSU1ACLineVoltage.0 + preprocessing: + - + type: MULTIPLIER + parameters: + - '0.1' + tags: + - + tag: Application + value: Energy + - + tag: Application + value: System + - + uuid: bc70a4482cb84e68b3344dfa8816de1e + name: 'System - PSU1 Output Current' + type: SNMP_AGENT + snmp_oid: .1.3.6.1.4.1.25026.7.1.2.6.2.2.0 + key: exciterPower1SupplyCurrent.0 + history: 180d + value_type: FLOAT + units: A + description: | + System - PSU1 Output Current + Mesurement of the Power Supply 1 total current consumption. + preprocessing: + - + type: MULTIPLIER + parameters: + - '0.1' + tags: + - + tag: Application + value: Energy + - + tag: Application + value: System + - + uuid: c4f77f6cf385463e92898a5ea476aa5a + name: 'Temperature - PSU1' + type: SNMP_AGENT + snmp_oid: .1.3.6.1.4.1.25026.7.1.2.6.2.5.0 + key: exciterPower1SupplyTemperature.0 + delay: 5m + history: 180d + value_type: FLOAT + units: '° C' + description: 'Measurement of the Power Supply 1 Temperature (Celcius).' + preprocessing: + - + type: MULTIPLIER + parameters: + - '0.1' + tags: + - + tag: Application + value: PSU + - + tag: Application + value: Temperature + - + uuid: 918ef9ac7bda470c9d7778212e716c85 + name: 'System - PSU2 Output (50V)' + type: SNMP_AGENT + snmp_oid: .1.3.6.1.4.1.25026.7.1.2.6.3.1.0 + key: exciterPower2Supply50v.0 + history: 180d + value_type: FLOAT + units: V + description: | + System - PSU2 Output (50V) + Mesurement of the +50V Power Supply 1 output.(Apply Mask 0,0) + preprocessing: + - + type: MULTIPLIER + parameters: + - '0.1' + tags: + - + tag: Application + value: Energy + - + tag: Application + value: System + - + uuid: bc8fc3ceb79f440ca7161350540fcd79 + name: 'System - PSU2 Voltage' + type: SNMP_AGENT + snmp_oid: .1.3.6.1.4.1.25026.7.1.2.6.3.3.0 + key: exciterPower2SupplyAc.0 + history: 180d + value_type: FLOAT + units: V + description: | + System - PSU2 Voltage + Measurement of the Power Supply 2 Input Voltage. + preprocessing: + - + type: MULTIPLIER + parameters: + - '0.1' + tags: + - + tag: Application + value: Energy + - + tag: Application + value: System + - + uuid: 6e52208e06ea48e99f6a931fb4a60a83 + name: 'Temperature - PSU2' + type: SNMP_AGENT + snmp_oid: .1.3.6.1.4.1.25026.7.1.2.6.3.5.0 + key: exciterPower2SupplyTemperature.0 + delay: 5m + history: 180d + value_type: FLOAT + units: '° C' + description: 'Measurement of the Power Supply 2 Temperature (Celcius).' + preprocessing: + - + type: MULTIPLIER + parameters: + - '0.1' + tags: + - + tag: Application + value: PSU + - + tag: Application + value: Temperature + - + uuid: a4a34d40b781413a8887167d52a14ee6 + name: 'System - Forward Power' + type: SNMP_AGENT + snmp_oid: .1.3.6.1.4.1.25026.7.1.2.1.2.0 + key: forwardPower.0 + delay: 15s + history: 180d + value_type: FLOAT + units: W + description: | + System - Forward Power + forwardPower.0 + preprocessing: + - + type: MULTIPLIER + parameters: + - '0.01' + tags: + - + tag: Application + value: 'Forward Power' + - + tag: Application + value: System + triggers: + - + uuid: ead7491500ad4c9aa231bc84dddc07bf + expression: 'last(/Template TX Hitachi EC7X0LP/forwardPower.0)<=({$PROGRAMMED_POWER} - ({$PROGRAMMED_POWER} * {$PERCENTUAL_POWER_AVAILABLE}))' + name: '{HOST.NAME} - Forward Power - Low' + priority: HIGH + description: 'Trigger of Forward Power Low.' + manual_close: 'YES' + - + uuid: 1cd7110fcc6c4e5b9ffddb0e214cb50b + expression: 'nodata(/Template TX Hitachi EC7X0LP/forwardPower.0,5m)=1' + name: '{HOST.NAME} - Forward Power - Nodata (5m)' + priority: INFO + description: 'Nodata of Trigger of Forward Power.' + manual_close: 'YES' + - + uuid: 7d9cc96471d44df6add427eca770426c + expression: 'nodata(/Template TX Hitachi EC7X0LP/forwardPower.0,24h)=1' + name: '{HOST.NAME} No data - without data collected for more 24h' + status: DISABLED + priority: WARNING + manual_close: 'YES' + - + uuid: 3340bc34cf3b49ccb3425c9631e0fbab + name: 'System - Power Amplifier Current' + type: SNMP_AGENT + snmp_oid: .1.3.6.1.4.1.25026.7.1.2.5.1.0 + key: paCurrent.0 + history: 180d + value_type: FLOAT + units: A + description: | + System - Power Amplifier Current + Power Amplifier Current + preprocessing: + - + type: MULTIPLIER + parameters: + - '0.01' + tags: + - + tag: Application + value: Energy + - + tag: Application + value: System + - + uuid: f17f266e940849f5bb398b046ad28fdf + name: 'Temperature - Power Amplifier' + type: SNMP_AGENT + snmp_oid: .1.3.6.1.4.1.25026.7.1.2.5.2.0 + key: paTemperature.0 + delay: 5m + history: 180d + value_type: FLOAT + units: '° C' + description: 'Power Amplifier Temperature (Celcius).' + preprocessing: + - + type: MULTIPLIER + parameters: + - '0.01' + tags: + - + tag: Application + value: 'Power Amplifier' + - + tag: Application + value: Temperature + - + uuid: cd0ffab8179e408cba75f0f71bc1bd56 + name: 'System - PSU2 Output Current' + type: SNMP_AGENT + snmp_oid: .1.3.6.1.4.1.25026.7.1.2.6.3.2.0 + key: power1PSU2PowerSupplyCurrent.0 + history: 180d + value_type: FLOAT + units: A + description: | + System - PSU2 Output Current + Mesurement of the Power Supply 2 total current consumption. + preprocessing: + - + type: MULTIPLIER + parameters: + - '0.1' + tags: + - + tag: Application + value: Energy + - + tag: Application + value: System + - + uuid: bb7641023c474b86a82f4c5fcb0755e5 + name: 'System - Multiplexer 1PPS Input' + type: SNMP_AGENT + snmp_oid: .1.3.6.1.4.1.25026.7.1.2.4.1.1.0 + key: ppsInput.0 + history: 180d + trends: '0' + value_type: TEXT + description: | + Status of the 1 Pulse Per Second (1PPS) reference for the internal time base. + SYNTAX INTEGER { notpresent(0), present(1). + preprocessing: + - + type: STR_REPLACE + parameters: + - '0' + - 'Not Present' + - + type: STR_REPLACE + parameters: + - '1' + - Present + tags: + - + tag: Application + value: Multiplexer + - + uuid: 5a0c3464d71f406a822763cc040a20de + name: 'System - Reflected Power' + type: SNMP_AGENT + snmp_oid: .1.3.6.1.4.1.25026.7.1.2.1.3.0 + key: reflectedPower.0 + delay: 15s + history: 180d + value_type: FLOAT + units: W + description: 'Measured of RF total reflected power at mask filter output.(Apply Mask 0,00).' + tags: + - + tag: Application + value: 'Forward Power' + - + tag: Application + value: System + triggers: + - + uuid: 8836b8e7634f448db37e319ddd6a6fa5 + expression: 'last(/Template TX Hitachi EC7X0LP/reflectedPower.0)>=({$PROGRAMMED_POWER} * {$PERCENTUAL_REFLECTED_WARNING})' + name: '{HOST.NAME} - Reflected Power >= 15%' + priority: WARNING + description: 'Reflected Power >= 15%' + manual_close: 'YES' + - + uuid: 804e85fdbd434eb692566c31b7202d71 + expression: 'last(/Template TX Hitachi EC7X0LP/reflectedPower.0)>=({$PROGRAMMED_POWER} * {$PERCENTUAL_REFLECTED_HIGH})' + name: '{HOST.NAME} - Reflected Power >= 20%' + priority: HIGH + description: 'Reflected Power >= 20%' + manual_close: 'YES' + - + uuid: 0ffacce4323646b089856233aa3799cd + name: 'System - Reflectometer (V)' + type: SNMP_AGENT + snmp_oid: .1.3.6.1.4.1.25026.7.1.2.1.5.0 + key: reflectedPowerSensorVoltage.0 + history: 180d + value_type: FLOAT + units: V + description: | + System - Reflectometer (V) + reflectedPowerSensorVoltage.0 + preprocessing: + - + type: MULTIPLIER + parameters: + - '0.01' + tags: + - + tag: Application + value: Energy + - + tag: Application + value: System + - + uuid: 4bae0b8498cc4f4d9680dc47559a088d + name: 'System - Multiplexer SFN Info' + type: SNMP_AGENT + snmp_oid: .1.3.6.1.4.1.25026.7.1.2.4.1.2.0 + key: sfnInfo.0 + history: 180d + trends: '0' + value_type: TEXT + description: | + Status of the SFN information (NSI) in the IIP within the BTS. + SYNTAX INTEGER { notpresent(0), present(1) } + preprocessing: + - + type: STR_REPLACE + parameters: + - '0' + - 'Not present' + - + type: STR_REPLACE + parameters: + - '1' + - Present + tags: + - + tag: Application + value: Multiplexer + - + uuid: e8fc32c8c2224236b21fdfa84d25ac93 + name: 'System - Uptime' + type: SNMP_AGENT + snmp_oid: .1.3.6.1.2.1.1.3.0 + key: sysUpTime.0 + delay: 1h + history: 180d + units: uptime + description: 'System Uptime' + preprocessing: + - + type: MULTIPLIER + parameters: + - '0.01' + tags: + - + tag: Application + value: System + macros: + - + macro: '{$PERCENTUAL_POWER_AVAILABLE}' + value: '0.20' + description: 'Rate of available the power of equipament - default (0.2 -> 20%)' + - + macro: '{$PERCENTUAL_REFLECTED_HIGH}' + value: '0.20' + description: 'Rate of available the reflected power of equipment - default (0.2 -> 20%) for high triggers' + - + macro: '{$PERCENTUAL_REFLECTED_WARNING}' + value: '0.15' + description: 'Rate of available the reflected power of equipment - default (0.15 -> 15%) for warning triggers' + - + macro: '{$PROGRAMMED_POWER}' + value: '0' + description: 'Power programmed of the equipament' + graphs: + - + uuid: 6ed44f124656470c80606b14affdf04c + name: 'Power Amplifier - Current' + show_work_period: 'NO' + graph_items: + - + color: 1A7C11 + calc_fnc: ALL + item: + host: 'Template TX Hitachi EC7X0LP' + key: paCurrent.0 + - + uuid: c175f08f4429465fbb599ac2e17d5408 + name: 'Power Amplifier - Temperature' + show_work_period: 'NO' + graph_items: + - + color: 1A7C11 + calc_fnc: ALL + item: + host: 'Template TX Hitachi EC7X0LP' + key: paTemperature.0 + - + uuid: 32a4c2ae4c914fa3935096a2d86ac043 + name: 'Power Supply - Current' + show_work_period: 'NO' + graph_items: + - + color: 1A7C11 + calc_fnc: ALL + item: + host: 'Template TX Hitachi EC7X0LP' + key: exciterPower1SupplyCurrent.0 + - + sortorder: '1' + color: F63100 + calc_fnc: ALL + item: + host: 'Template TX Hitachi EC7X0LP' + key: power1PSU2PowerSupplyCurrent.0 + - + uuid: 68d2138046be4151af0cccff7f6c9d9d + name: 'Power Supply - Temperature' + show_work_period: 'NO' + graph_items: + - + color: 1A7C11 + calc_fnc: ALL + item: + host: 'Template TX Hitachi EC7X0LP' + key: exciterPower1SupplyTemperature.0 + - + sortorder: '1' + color: F63100 + calc_fnc: ALL + item: + host: 'Template TX Hitachi EC7X0LP' + key: exciterPower2SupplyTemperature.0 + - + uuid: bc07e98087ae4d5baddc4fde962233ee + name: 'Power Supply - Voltage' + show_work_period: 'NO' + graph_items: + - + color: 1A7C11 + calc_fnc: ALL + item: + host: 'Template TX Hitachi EC7X0LP' + key: exciterPower1SupplyAc.0 + - + sortorder: '1' + color: F63100 + calc_fnc: ALL + item: + host: 'Template TX Hitachi EC7X0LP' + key: exciterPower2SupplyAc.0 + - + uuid: 6f65f3539f09413b9a1ffe068a26439f + name: 'Power Supply - Voltage (50V)' + show_work_period: 'NO' + graph_items: + - + color: 1A7C11 + calc_fnc: ALL + item: + host: 'Template TX Hitachi EC7X0LP' + key: exciterPower1Supply50v.0 + - + sortorder: '1' + color: F63100 + calc_fnc: ALL + item: + host: 'Template TX Hitachi EC7X0LP' + key: exciterPower2Supply50v.0 + - + uuid: b65971bd25be4d499aca16aef2815c32 + name: 'System - Forward Data' + show_work_period: 'NO' + graph_items: + - + color: DCE775 + calc_fnc: ALL + item: + host: 'Template TX Hitachi EC7X0LP' + key: alcVoltage.0 + - + sortorder: '1' + color: 1A7C11 + calc_fnc: ALL + item: + host: 'Template TX Hitachi EC7X0LP' + key: forwardPower.0 + - + sortorder: '2' + color: 2774A4 + calc_fnc: ALL + item: + host: 'Template TX Hitachi EC7X0LP' + key: reflectedPower.0 + - + sortorder: '3' + color: A54F10 + calc_fnc: ALL + item: + host: 'Template TX Hitachi EC7X0LP' + key: reflectedPowerSensorVoltage.0 + - + uuid: 7f8a74b8a5334aceb4e9bdf5443b68af + name: 'System - Forward Power' + show_work_period: 'NO' + graph_items: + - + drawtype: FILLED_REGION + color: 1A7C11 + calc_fnc: ALL + item: + host: 'Template TX Hitachi EC7X0LP' + key: forwardPower.0 + - + uuid: 953a90a398484b11b4792a9a51e44619 + name: 'System - Uptime' + show_work_period: 'NO' + graph_items: + - + color: 1A7C11 + calc_fnc: ALL + item: + host: 'Template TX Hitachi EC7X0LP' + key: sysUpTime.0