Skip to content

Latest commit

 

History

History
executable file
·
243 lines (171 loc) · 8.27 KB

6938843600375_0_0.md

File metadata and controls

executable file
·
243 lines (171 loc) · 8.27 KB
layout title
documentation
Cooltouch - ZWave

{% include base.html %}

Cooltouch Z-Wave Switch 3-gang White

This describes the Z-Wave device Cooltouch, manufactured by Chengputech with the thing type UID of chengputech_6938843600375_00_000.

The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.

Cooltouch product image

The Cooltouch supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

COOLTOUCH Z-Wave smart switch with touch panel. Curved touch buttons with glowing ring per button. Atmel MCU, Bayer case, Tyco relay, aluminium bezel.

Specification
Standard: Z-Wave Plus
Voltage: AC90~250V, 50/60Hz (Neutral & Live wire required)
Load: resistive one of 500W, capacitive one of 200W
Maximum Current: 5A, impact resistance TV-5
Remote Distance: Indoor of 40m, outdoor of 80m
Remote Control Configuration: 0-close / 255-open
Frequency: 868.42MHz
Certification: CE, RoHS

Dimensions
Switch Size: 86 x 86 x 38.6mm
Depth: 30mm

Inclusion Information

  • Tap any button on the switch, it lights up white.
  • Press and hold the same button until all buttons start glowing.
  • Then tap any button 3 times within 1 second.

Exclusion Information

  • Tap any button on the switch, it lights up white.
  • Press and hold the same button until all buttons start glowing.
  • Then tap any button 3 times within 1 second.

General Usage Information

First turn off the mains, then connect up the wires at the back, install into the wall box, switch on the mains circuit power to the switch, now feel free to turn lights on and off as you please.

Channels

The following table summarises the channels available for the Cooltouch -:

Channel Name Channel ID Channel Type Category Item Type
Switch switch_binary switch_binary Switch Switch
Alarm alarm_general alarm_general Alarm Switch
Switch 1 switch_binary1 switch_binary Switch Switch
Alarm 1 alarm_general1 alarm_general Alarm Switch
Switch 2 switch_binary2 switch_binary Switch Switch
Alarm 2 alarm_general2 alarm_general Alarm Switch
Switch 3 switch_binary3 switch_binary Switch Switch
Alarm 3 alarm_general3 alarm_general Alarm Switch

Switch

Switch the power on and off.

The switch_binary channel is of type switch_binary and supports the Switch item and is in the Switch category.

Alarm

Indicates if an alarm is triggered.

The alarm_general channel is of type alarm_general and supports the Switch item and is in the Alarm category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Switch 1

Switch the power on and off.

The switch_binary1 channel is of type switch_binary and supports the Switch item and is in the Switch category.

Alarm 1

Indicates if an alarm is triggered.

The alarm_general1 channel is of type alarm_general and supports the Switch item and is in the Alarm category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Switch 2

Switch the power on and off.

The switch_binary2 channel is of type switch_binary and supports the Switch item and is in the Switch category.

Alarm 2

Indicates if an alarm is triggered.

The alarm_general2 channel is of type alarm_general and supports the Switch item and is in the Alarm category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Switch 3

Switch the power on and off.

The switch_binary3 channel is of type switch_binary and supports the Switch item and is in the Switch category.

Alarm 3

Indicates if an alarm is triggered.

The alarm_general3 channel is of type alarm_general and supports the Switch item and is in the Alarm category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Device Configuration

The following table provides a summary of the 1 configuration parameters available in the Cooltouch. Detailed information on each parameter can be found in the sections below.

Param Name Description
0 Remote Control Remote Control Configuration

Parameter 0: Remote Control

Remote Control Configuration

The following option values may be configured -:

Value Description
0 close
255 Open

The manufacturer defined default value is 0 (close).

This parameter has the configuration ID config_0_1 and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The Cooltouch supports 1 association group.

Group 1: Controller

Association group 1 supports 1 node.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_MULTI_CHANNEL_V2
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_ALARM_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1
COMMAND_CLASS_ASSOCIATION_V1
COMMAND_CLASS_VERSION_V1
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V2
COMMAND_CLASS_SECURITY_V1

Endpoint 1

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_MULTI_CHANNEL_V2
COMMAND_CLASS_ALARM_V1
COMMAND_CLASS_ASSOCIATION_V1
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V2
COMMAND_CLASS_SECURITY_V1

Endpoint 2

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_MULTI_CHANNEL_V2
COMMAND_CLASS_ALARM_V1
COMMAND_CLASS_ASSOCIATION_V1
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V2
COMMAND_CLASS_SECURITY_V1

Endpoint 3

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_MULTI_CHANNEL_V2
COMMAND_CLASS_ALARM_V1
COMMAND_CLASS_ASSOCIATION_V1
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V2
COMMAND_CLASS_SECURITY_V1

Documentation Links


Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.