layout | title |
---|---|
documentation |
PSC234ZW - ZWave |
{% include base.html %}
This describes the Z-Wave device *PSC234ZW *, manufactured by permundo GmbH with the thing type UID of permundo_psc234zw_00_000
.
The device is in the category of Power Outlet, defining Small devices to be plugged into a power socket in a wall which stick there.
The PSC234ZW supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
The wireless plug socket PSC234ZW allows you to remotely control electrical appliances.
It features a metering function to measure the power consumption and the accumulated energy usage of connected equipment. The built-in metering unit is of high quality: it calculates the true-power and also works for small loads from 1W upwards. This feature is important to have a correct measurement value also for electronic loads like led lamps.
The PSC234ZW has a built-in safety features that will switch-off the output in case of too high temperature or overload.
Additionally the PSC234 has a feature to switch the load on at zero voltage and switch the load off at zero current. This leads to a very high number of possible switching cycles also for difficult loads like led-lamps or motors, e.g. pumps.
When a PSC234 that is not associated to a Z-Wave Network, is inserted into the mains outlet, it will flash once red followed by 2 green flashed followed by steady red flashing. The PSC234 can now be added to (=inclusion) or removed from (=exclusion) a Z-Wave network:
- Hold the touch button until the led shows green light
- Release the touch button
The PSC234 will confirm successful addition to the network by 5 green flashes.
When a PSC234 that is not associated to a Z-Wave network, is inserted into the mains outlet, it will flash once red followed by 2 green flashed followed by steady red flashing. The PSC234 can now be added to (=inclusion) or removed from (=exclusion) a Z-Wave network:
- Hold the touch button until the led shows green light
- Release the touch button
The PSC234 will confirm successful removal/exclusion by steady red flashing. At the time of exclusion the device is factory reset.
Factory Reset:
Please use this procedure only if the primary controller is missing or inoperable:
The device can be put into factory default state manually by the following procedure:
- Hold the touch-button until the led shows red light
- Release the touch-button and hold the touch-button again until the led starts to flash green
The PSC234 confirms the successful completion of the factory reset procedure by steady red flashing.
The following table summarises the channels available for the PSC234ZW -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Switch | switch_binary | switch_binary | Switch | Switch |
Electric meter (kWh) | meter_kwh | meter_kwh | Energy | Number |
Electric meter (watts) | meter_watts | meter_watts | Energy | Number |
Switch the power on and off.
The switch_binary
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
Indicates the energy consumption (kWh).
The meter_kwh
channel is of type meter_kwh
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous power consumption.
The meter_watts
channel is of type meter_watts
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
The following table provides a summary of the 1 configuration parameters available in the PSC234ZW . Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
31 | LocalControlOff | Disable local control of plug |
Disable local control of plug 31d Size:1 Default: 00d
Bit 0:
1=LocalControlOff
0=LocalControlOn
Bit 1-7: 0 (siehe auch CC_PROTECTION)
LocalControlOff: In der Werkseinstellung (LocalControlOff=0) ändert das Gerät den Zustand des Ausgangs bei Betätigung des TouchButtons. Durch das Setzen von LocalControlOff=1 kann der Ausgang des Geräts nur noch über Z-Wave+ gesteuert werden.
LocalControlOff wird entweder über Parameter 31 der CC_CONFIGURATION oder über CC_PROTECTION, PROTECTION_SET konfiguriert. The following option values may be configured -:
Value | Description |
---|---|
0 | Enable Local Control |
1 | Disable Local Control |
The manufacturer defined default value is 0
(Enable Local Control).
This parameter has the configuration ID config_31_1
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The PSC234ZW supports 1 association group.
Reports triggered by change of relay state, meter values or time Assoziationsgruppe Gruppe 1 (lifeline): 5 Events/Notifications:
(1) Sendet COMMAND_CLASS_BASIC, BASIC_REPORT und COMMAND_CLASS_SWITCH_BINARY, BINARY_REPORT jeweils nach Änderung des RelaisStatus.
(2) Sendet COMMAND_CLASS_METER_V2, METER_REPORT_V2 jeweils nach Änderung der Messwerte Energie oder Leistung entweder um einen Minimalbetrag, oder nach Ablauf einer Maximalzeit. Ebenso wird nach jedem Report eine Mindestzeit gewartet, bevor ein nächster Report gesendet wird. Zeiten für Werte Energie/Leistung:
Mindestzeit zwischen 2 Reports: 1s PSC234ZW RC2.05 G3 DE 7
Maximalzeit bis zum nächsten Report: 15min. Trigger bei Abweichung seit letzter Messung: 4% Leistung (mind. 2W) oder 1Wh Energie
Association group 1 supports 1 node.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_METER_V2 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V2 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V2 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V2 | |
COMMAND_CLASS_CONFIGURATION_V2 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_PROTECTION_V1 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.