// Quality61850.h
// Implementation of the Class Quality61850
// Created on: 07-fev-2014 11:44:18
///////////////////////////////////////////////////////////
#if !defined(EA_782097D3_5DD4_40ac_AA9B_7D79B085A041__INCLUDED_)
#define EA_782097D3_5DD4_40ac_AA9B_7D79B085A041__INCLUDED_
#include "Boolean.h"
#include "Source.h"
#include "Validity.h"
/**
* Quality flags in this class are as defined in IEC 61850, except for
* estimatorReplaced, which has been included in this class for convenience.
*/
class Quality61850
{
public:
Quality61850();
virtual ~Quality61850();
/**
* Measurement value may be incorrect due to a reference being out of calibration.
*/
Boolean badReference;
/**
* Value has been replaced by State Estimator. estimatorReplaced is not an
* IEC61850 quality bit but has been put in this class for convenience.
*/
Boolean estimatorReplaced;
/**
* This identifier indicates that a supervision function has detected an internal
* or external failure, e.g. communication failure.
*/
Boolean failure;
/**
* Measurement value is old and possibly invalid, as it has not been successfully
* updated during a specified time interval.
*/
Boolean oldData;
/**
* Measurement value is blocked and hence unavailable for transmission.
*/
Boolean operatorBlocked;
/**
* To prevent some overload of the communication it is sensible to detect and
* suppress oscillating (fast changing) binary inputs. If a signal changes in a
* defined time (tosc) twice in the same direction (from 0 to 1 or from 1 to 0)
* then oscillation is detected and the detail quality identifier "oscillatory" is
* set. If it is detected a configured numbers of transient changes could be
* passed by. In this time the validity status "questionable" is set. If after
* this defined numbers of changes the signal is still in the oscillating state
* the value shall be set either to the opposite state of the previous stable
* value or to a defined default value. In this case the validity status
* "questionable" is reset and "invalid" is set as long as the signal is
* oscillating. If it is configured such that no transient changes should be
* passed by then the validity status "invalid" is set immediately in addition to
* the detail quality identifier "oscillatory" (used for status information only).
*/
Boolean oscillatory;
/**
* Measurement value is beyond a predefined range of value.
*/
Boolean outOfRange;
/**
* Measurement value is beyond the capability of being represented properly. For
* example, a counter value overflows from maximum count back to a value of zero.
*/
Boolean overFlow;
/**
* Source gives information related to the origin of a value. The value may be
* acquired from the process, defaulted or substituted.
*/
Source source;
/**
* A correlation function has detected that the value is not consitent with other
* values. Typically set by a network State Estimator.
*/
Boolean suspect;
/**
* Measurement value is transmitted for test purposes.
*/
Boolean test;
/**
* Validity of the measurement value.
*/
Validity validity;
};