After building OpenBMC, you will end up with a set of image files in
tmp/deploy/images/<platform>/
. The image-*
symlinks correspond to components
that can be updated on the BMC:
-
image-bmc
→flash-<platform>-<timestamp>
The whole-of-flash image for the BMC
-
image-initramfs
→core-image-minimal-initramfs-palmetto.cpio.lzma.u-boot
The small initramfs image; used for early init and flash management
-
image-kernel
→cuImage
The OpenBMC kernel cuImage (combined kernel and device tree)
-
image-rofs
→obmc-phosphor-image-palmetto.squashfs-xz
The read-only OpenBMC filesystem
-
image-rwfs
→rwfs.jffs2
The read-write filesystem for persistent changes to the OpenBMC filesystem
-
image-u-boot
→u-boot.bin
The OpenBMC bootloader
Additionally, there are two tar-balls created that can be deloyed and unpacked by REST:
-
<platform>-<timestamp>.all.tar
The complete BMC flash content: A single file wrapped in a tar archive
-
<platform>-<timestamp>.tar
Partitioned BMC flash content: Multiple files wrapped in a tar archive, one for each of the u-boot, kernel, initramfs, ro and rw partitions.
The BMC normally runs with the read-write and read-only file systems mounted, which means these images may be read (and written, for the read-write filesystem) at any time. Because the updates are distributed as complete file system images, these filesystems have to be unmounted to replace them with new images. To unmount these file systems all applications must be stopped.
By default an orderly reboot
will stop all applications and unmount
the root filesystem, and the images copied into the /run/initramfs
directory will be applied at that point before restarting. This also
applied to the shutdown
and halt
commands -- they will write the
flash before stopping.
As an alternative, the an option can be parsed by the init
script in
the initramfs to copy the required contents of these filesystems into
RAM so the images can be applied while the rest of the application stack
is running and progress can be monitored over the network. The
update
script can then be called to write the images while the
system is operational and its progress output monitored.
To update from the OpenBMC shell, follow the steps in this section.
It is recommended that the BMC be prepared for update:
fw_setenv openbmconce copy-files-to-ram copy-base-filesystem-to-ram
reboot
Copy one or more of these image-*
files to the directory:
/run/initramfs/
(preserving the filename), then run the update
script to apply the images:
/run/initramfs/update
then reboot to finish applying:
reboot
During the reboot process the update
script will be invoked after
the file systems are unmounted to complete the update process.
Some optional features are available, see the help for more details:
/run/initramfs/update --help
An OpenBMC system can download an update image from a TFTP server, and apply updates, controlled via REST. The general procedure is:
- Prepare system for update
- Configure update settings
- Initiate update
- Check flash status
- Apply update
- Reboot the BMC
Perform a POST to invoke the PrepareForUpdate
method of the /flash/bmc
object:
curl -b cjar -k -H "Content-Type: application/json" -X POST \
-d '{"data": []}' \
https://bmc/org/openbmc/control/flash/bmc/action/prepareForUpdate
This will setup the u-boot environment and reboot the BMC. If no other images were pending the BMC should return in about 2 minutes.
There are a few settings available to control the update process:
preserve_network_settings
: Preserve network settings, only needed if updating the whole flashrestore_application_defaults
: update (clear) the read-write file systemupdate_kernel_and_apps
: update kernel and initramfs. If the partitioned tarball will be used for update then this option must be set. Otherwise, if the complete tarball will be used then this option must not be set.clear_persistent_files
: ignore the persistent file list when resetting applications defaultsauto_apply
: Attempt to write the images by invoking theApply
method after the images are unpacked.
To configure the update settings, perform a REST PUT to
/control/flash/bmc/attr/<setting>
. For example:
curl -b cjar -k -H "Content-Type: application/json" -X PUT \
-d '{"data": 1}' \
https://bmc/org/openbmc/control/flash/bmc/attr/preserve_network_settings
Perform a POST to invoke the updateViaTftp
method of the /flash/bmc
object:
curl -b cjar -k -H "Content-Type: application/json" -X POST \
-d '{"data": ["<TFTP server IP address>", "<filename>"]}' \
https://bmc/org/openbmc/control/flash/bmc/action/updateViaTftp
Note the <filename>
shall be a tar-ball.
You can query the progress of the download and image verificaton with a simple GET request:
curl -b cjar -k https://bmc/org/openbmc/control/flash/bmc
Or perform a POST to invoke the GetUpdateProgress
method of the /flash/bmc
object:
curl -b cjar -k -H "Content-Type: application/json" -X POST \
-d '{"data": []}' \
https://bmc/org/openbmc/control/flash/bmc/action/GetUpdateProgress
Note:
- During downloading the tar-ball, the progress status is
Downloading
- After the tar-ball is downloaded and verified, the progress status becomes
Image ready to apply
.
If the status is Image ready to apply.
then you can either initiate
a reboot or call the Apply method to start the process of writing the
flash:
curl -b cjar -k -H "Content-Type: application/json" -X POST \
-d '{"data": []}' \
https://bmc/org/openbmc/control/flash/bmc/action/Apply
Now the image is being flashed, you can check the progress with above step’s command as well.
- During flashing the image, the status becomes
Writing images to flash
- After it’s flashed and verified, the status becomes
Apply Complete. Reboot to take effect.
To start using the new images, reboot the BMC using the warmReset method of the BMC control object:
curl -b cjar -k -H "Content-Type: application/json" -X POST \
-d '{"data": []}' \
https://bmc/org/openbmc/control/bmc0/action/warmReset
The host firmware (or "BIOS") can be updated in a similar method. Because the BMC does not use the host firmware it is updated when the download is completed. This assumes the host is not accessing its firmware.
Perform a POST request to call the updateViaTftp
method of
/control/flash/bios
(instead of /control/flash/bmc
used above). To initiate
the update:
curl -b cjar -k -H "Content-Type: application/json" -X POST \
-d '{"data": ["<TFTP server IP address>", "<filename>"]}' \
https://bmc/org/openbmc/control/flash/bios/action/updateViaTftp
And to check the flash status:
curl -b cjar -k https://bmc/org/openbmc/control/flash/bios