CREATE TABLE IF NOT EXISTS `toner` ( `toner_id` int(11) NOT NULL auto_increment, `device_id` int(11) NOT NULL default '0', `toner_index` int(11) NOT NULL, `toner_type` varchar(64) NOT NULL, `toner_oid` varchar(64) NOT NULL, `toner_descr` varchar(32) NOT NULL default '', `toner_capacity` int(11) NOT NULL default '0', `toner_current` int(11) NOT NULL default '0', PRIMARY KEY (`toner_id`), KEY `device_id` (`device_id`)) ENGINE=InnoDB DEFAULT CHARSET=latin1;
ALTER TABLE `mempools` CHANGE `mempool_descr` `mempool_descr` VARCHAR( 64 ) CHARACTER SET latin1 COLLATE latin1_swedish_ci NOT NULL;
ALTER TABLE `processors` CHANGE `processor_descr` `processor_descr` VARCHAR( 64 ) CHARACTER SET latin1 COLLATE latin1_swedish_ci NOT NULL;
DROP TABLE `cmpMemPool`;
ALTER TABLE `mempools` CHANGE `mempool_used` `mempool_used` BIGINT( 16 ) NOT NULL ,CHANGE `mempool_free` `mempool_free` BIGINT( 16 ) NOT NULL ,CHANGE `mempool_total` `mempool_total` BIGINT( 16 ) NOT NULL ,CHANGE `mempool_largestfree` `mempool_largestfree` BIGINT( 16 ) NULL DEFAULT NULL ,CHANGE `mempool_lowestfree` `mempool_lowestfree` BIGINT( 16 ) NULL DEFAULT NULL ;
CREATE TABLE IF NOT EXISTS `frequency` ( `freq_id` int(11) NOT NULL auto_increment, `device_id` int(11) NOT NULL default '0', `freq_oid` varchar(64) NOT NULL, `freq_index` varchar(8) NOT NULL, `freq_type` varchar(32) NOT NULL, `freq_descr` varchar(32) NOT NULL default '', `freq_precision` int(11) NOT NULL default '1', `freq_current` float default NULL, `freq_limit` float default NULL, `freq_limit_low` float default NULL, PRIMARY KEY (`freq_id`), KEY `freq_host` (`device_id`)) ENGINE=MyISAM AUTO_INCREMENT=189 DEFAULT CHARSET=latin1;
CREATE TABLE IF NOT EXISTS `current` ( `current_id` int(11) NOT NULL auto_increment, `device_id` int(11) NOT NULL default '0', `current_oid` varchar(64) NOT NULL, `current_index` varchar(8) NOT NULL, `current_type` varchar(32) NOT NULL, `current_descr` varchar(32) NOT NULL default '', `current_precision` int(11) NOT NULL default '1', `current_current` float default NULL, `current_limit` float default NULL, `current_limit_warn` float default NULL, `current_limit_low` float default NULL, PRIMARY KEY (`current_id`), KEY `current_host` (`device_id`)) ENGINE=MyISAM AUTO_INCREMENT=189 DEFAULT CHARSET=latin1;
ALTER TABLE `ports` CHANGE `ifDescr` `ifDescr` VARCHAR(255) NOT NULL;
CREATE TABLE IF NOT EXISTS `ucd_diskio` ( `diskio_id` int(11) NOT NULL AUTO_INCREMENT, `device_id` int(11) NOT NULL, `diskio_index` int(11) NOT NULL, `diskio_descr` varchar(32) NOT NULL, PRIMARY KEY (`diskio_id`)) ENGINE=MyISAM DEFAULT CHARSET=latin1 AUTO_INCREMENT=11 ;
ALTER TABLE `eventlog` CHANGE `type` `type` VARCHAR( 64 ) CHARACTER SET latin1 COLLATE latin1_swedish_ci NULL DEFAULT NULL;
CREATE TABLE IF NOT EXISTS `applications` ( `app_id` int(11) NOT NULL AUTO_INCREMENT, `device_id` int(11) NOT NULL, `app_type` varchar(64) NOT NULL, PRIMARY KEY (`app_id`)) ENGINE=MyISAM DEFAULT CHARSET=latin1 AUTO_INCREMENT=5 ;
## 0.10.6
CREATE TABLE IF NOT EXISTS `sensors` ( `sensor_id` int(11) NOT NULL auto_increment, `sensor_class` varchar(64) NOT NULL, `device_id` int(11) NOT NULL default '0', `sensor_oid` varchar(64) NOT NULL, `sensor_index` varchar(8) NOT NULL, `sensor_type` varchar(32) NOT NULL, `sensor_descr` varchar(32) NOT NULL default '', `sensor_precision` int(11) NOT NULL default '1', `sensor_current` float default NULL, `sensor_limit` float default NULL, `sensor_limit_warn` float default NULL, `sensor_limit_low` float default NULL, `sensor_limit_low_warn` float default NULL, PRIMARY KEY (`sensor_id`), KEY `sensor_host` (`device_id`)) ENGINE=MyISAM AUTO_INCREMENT=189 DEFAULT CHARSET=latin1;
ALTER TABLE `devices` CHANGE `type` `type` VARCHAR(20) NOT NULL;
ALTER TABLE `voltage` CHANGE `volt_index` `volt_index` VARCHAR(10) NOT NULL;
ALTER TABLE `frequency` CHANGE `freq_index` `freq_index` VARCHAR(10) NOT NULL;
ALTER TABLE `sensors` CHANGE `sensor_index` `sensor_index` VARCHAR(10) NOT NULL;
DROP TABLE `fanspeed`;
DROP TABLE `voltage`;
DROP TABLE `current`;
ALTER TABLE `processors` ADD INDEX ( `device_id` );
ALTER TABLE `ucd_diskio` ADD INDEX ( `device_id` );
ALTER TABLE `storage` ADD INDEX ( `device_id` );
ALTER TABLE `mac_accounting` ADD INDEX ( `interface_id` );
ALTER TABLE `ipv4_addresses` ADD INDEX ( `interface_id` );
ALTER TABLE `ipv6_addresses` ADD INDEX ( `interface_id` );
ALTER TABLE `ipv4_mac` ADD INDEX ( `interface_id` );
CREATE TABLE IF NOT EXISTS `ports_adsl` ( `interface_id` int(11) NOT NULL, `port_adsl_updated` timestamp NOT NULL DEFAULT CURRENT_TIMESTAMP, `adslLineCoding` varchar(8) COLLATE utf8_bin NOT NULL, `adslLineType` varchar(16) COLLATE utf8_bin NOT NULL, `adslAtucInvVendorID` varchar(8) COLLATE utf8_bin NOT NULL, `adslAtucInvVersionNumber` varchar(8) COLLATE utf8_bin NOT NULL, `adslAtucCurrSnrMgn` decimal(5,1) NOT NULL, `adslAtucCurrAtn` decimal(5,1) NOT NULL, `adslAtucCurrOutputPwr` decimal(5,1) NOT NULL, `adslAtucCurrAttainableRate` int(11) NOT NULL, `adslAtucChanCurrTxRate` int(11) NOT NULL, `adslAturInvSerialNumber` varchar(8) COLLATE utf8_bin NOT NULL, `adslAturInvVendorID` varchar(8) COLLATE utf8_bin NOT NULL, `adslAturInvVersionNumber` varchar(8) COLLATE utf8_bin NOT NULL, `adslAturChanCurrTxRate` int(11) NOT NULL, `adslAturCurrSnrMgn` decimal(5,1) NOT NULL, `adslAturCurrAtn` decimal(5,1) NOT NULL, `adslAturCurrOutputPwr` decimal(5,1) NOT NULL, `adslAturCurrAttainableRate` int(11) NOT NULL, UNIQUE KEY `interface_id` (`interface_id`)) ENGINE=InnoDB DEFAULT CHARSET=utf8 COLLATE=utf8_bin;
## 0.10.7
CREATE TABLE IF NOT EXISTS `perf_times` ( `type` varchar(8) NOT NULL, `doing` varchar(64) NOT NULL, `start` int(11) NOT NULL, `duration` double(5,2) NOT NULL, `devices` int(11) NOT NULL, KEY `type` (`type`)) ENGINE=InnoDB DEFAULT CHARSET=utf8 COLLATE=utf8_bin;