AXI4-Lite Mailbox

axi_lite_mailbox implements a hardware mailbox, where two AXI4-Lite slave ports are connected to each other over two FIFOs. Data written on port 0 is made available on the read data at port 1 and vice versa. The module features an interrupt for each port which can be enabled with the IRQEN register. Interrupts can be configured to trigger depending on the fill levels of the read (RIRQT) and write (WIRQT) FIFO. It is further possible to trigger an interrupt on an mailbox error condition as defined by the ERROR register.

Module Parameters

This table describes the parameters of the module.

Name Type Description
MailboxDepth int unsigned The depth of the FIFOs between the two slave ports, min 32'd2
IrqEdgeTrig bit Interrupts trigger mode.
[0]: level trigger
[1]: edge trigger
IrqActHigh bit Interrupts polarity.
[0]: active low / falling edge
[1]: active high / rising edge
AxiAddrWidth int unsigned The AXI4-Lite address width on the AW and AR channels
AxiDataWidth int unsigned The AXI4-Lite data width on the W and R channels
req_lite_t type In accordance with the AXI_LITE_TYPEDEF_REQ_T macro
resp_lite_t type In accordance with the AXI_LITE_TYPEDEF_RESP_T macro

Module Ports

This table describes the ports of the module.

Name Type Description
clk_i input logic clock
rst_ni input logic asynchronous reset active low
test_i input logic testmode enable
slv_reqs_i input req_lite_t [1:0] requests of the two AXI4-Lite ports
slv_resps_o output resp_lite_t [1:0] responses of the two AXI4-Lite ports
irq_o output logic [1:0] interrupt output for each port
base_addr_i input addr_t [1:0] base address for each port

Register Address Mapping

This table describes the type of register and the respective address mapping. The address depends on the parameter AxiDataWidth and the respective base_addr_i[*] of the port accociated to the index. There are two example columns given for the resulting address for a base_addr_i[*] of '0 and AxiDataWidth of 32 and 64 bit. Each register has one of the acces types R/W = read and write, R = read-only and W = write-only. Writes to read-only and reads from write-only registers are responded by an axi_pkg::RESP_SLVERR.

Base Address + Offset*AxiDataWidth/8 Address for AxiDataWidth = 32 Address for AxiDataWidth = 64 Register Name Access Type Default Value Description
base_addr_i + 0*AxiDataWidth/8 0x00 0x00 MBOXW W N/A Write data address
base_addr_i + 1*AxiDataWidth/8 0x04 0x08 MBOXR R N/A Read data address
base_addr_i + 2*AxiDataWidth/8 0x08 0x10 STATUS R 0x1 Status flags of the mailbox
base_addr_i + 3*AxiDataWidth/8 0x0C 0x18 ERROR R 0x0 Error flags
base_addr_i + 4*AxiDataWidth/8 0x10 0x20 WIRQT R/W 0x0 Write data interrupt threshold
base_addr_i + 5*AxiDataWidth/8 0x14 0x28 RIRQT R/W 0x0 Read data interrupt threshold
base_addr_i + 6*AxiDataWidth/8 0x18 0x30 IRQS R/W 0x0 Interrupt status register
base_addr_i + 7*AxiDataWidth/8 0x1C 0x38 IRQEN R/W 0x0 Interrupt enable register
base_addr_i + 8*AxiDataWidth/8 0x20 0x40 IRQP R 0x0 Interrupt pending register
base_addr_i + 9*AxiDataWidth/8 0x24 0x48 CRTL R/W 0x0 Module control register

MBOXW Register

Mailbox write register. Write here to send data to the other slave port. A interrupt request will be raised when the fill pointer of the FIFO surpasses the WIRQT Register (if enabled). Writes are ignored when the FIFO is full and a axi_pkg::RESP_SLVERR is returned. Additionally the corresponding bit in the ERROR Register is set.

MBOXR Register

Mailbox read register. Read here to recieve data from the other slave port. A interrupt request will be raised when the fill pointer of the FIFO surpasses the RIRQT Register (if enabled). When the FIFO is empty the read response axi_pkg::RESP_SLVERR is returned. Additionally the corresponding bit in the ERROR Register is set.

STATUS Register

Mailbox status register. This register holds the current status of the mailbox.

Bit(s) Name Access Type Reset Value Description
AxiDataWidth-1:4 Reserved Reserved
3 WFIFOL R 1'b0 Write FIFO level is higher than the threshold set in WIRQT
[0]: Write FIFO level is less or equal to the threshold.
[1]: Write FIFO level is higher than the threshold.
2 RFIFOL R 1'b0 Read FIFO level is higher than the threshold set in RIRQT
[0]: Write Read level is less or equal to the threshold.
[1]: Read FIFO level is higher than the threshold.
1 Full R 1'b0 Write FIFO is full and subsequent writes to MBOX are ignored
[0]: Space for write data.
[1]: No space for data, writes are ignored and error on transaction is generated.
0 Empty R 1'b1 Read FIFO is empty
[0]: Data is available.
[1]: No available data, reads respond with axi_pkg::RESP_SLVERR.

ERROR Register

Mailbox error register. This read only register contains information if from an empty read FIFO was read, or to a full FIFO was data written and ignored. This register is cleared on read.

Bit(s) Name Access Type Reset Value Description
AxiDataWidth-1:2 Reserved Reserved
1 Full R 1'b0 Attempted write to a full MBOX.
[0]: No Error.
[1]: MBOX write error.
0 Empty R 1'b1 Attempted read from an empty MBOX
[0]: No Error.
[1]: MBOX read error.

WIRQT Register

Write interrupt request threshold register for a slave port. The corresponding STATUS register bit is set, when the usage pointer of the FIFO connected to the W channel passes this value. When a value larger or equal than the parameter MailboxDepth is written to this register, it gets reduced to MailboxDepth - 1 to ensure an interrupt request trigger on FIFO usage, when the write FIFO is full.

Bit(s) Name Access Type Reset Value Description
AxiDataWidth-1:$clog2(MailboxDepth) Reserved Reserved
$clog2(MailboxDepth)-1:0 WIRQT R/W '0 The lower $clog2(MailboxDepth) bits are used

RIRQT Register

Read interrupt request threshold register for a slave port. The corresponding STATUS register bit is set, when the fill pointer of the FIFO connected to the R channel passes this value. When a value larger or equal than the parameter MailboxDepth is written to this register, it gets reduced to MailboxDepth - 1 to ensure an interrupt request trigger on FIFO usage, when the read FIFO is full.

Bit(s) Name Access Type Reset Value Description
AxiDataWidth-1:$clog2(MailboxDepth) Reserved Reserved
$clog2(MailboxDepth)-1:0 RIRQT R/W '0 The lower $clog2(MailboxDepth) bits are used

IRQS Register

Interrupt request status register. This register holds the current interrupt status of this slave port. There are three types of interrupts which can be enabled in the IRQEN register. The bits inside this register are sticky and get set when the trigger condition is fulfilled. This register has to be cleared explicitly by acknowledging the interrupt request status described below. This register will also fire, when the respective interrupt is not enabled.

  • EIRQ: Error interrupt request, is set to high, when there was an attempted read from an empty MBOX or to write on a full MBOX.
  • RTIRQ: Read threshold interrupt request, is set to high when the fill pointer of the FIFO connected to the R channel is higher than the threshold set in RIRQT.
  • WEIRQ: Write error interrupt request, is set to high, when there was an attempted write to a full write FIFO. Will not change when the interrupt is not enabled in IRQEN. This register allows acknowledgment of the respective interrupts. To acknowledge an interrupt request write a 1'b1 to the corresponding bit described in following table.
Bit(s) Name Access Type Reset Value Description
AxiDataWidth-1:3 Reserved Reserved
2 EIRQ R/W 1'b0 On read:
[0]: No interrupt request
[1]: Error on MBOX access
On write:
[0]: No acknowledge
[1]: Acknowledge and clear interrupt request
1 RTIRQ R/W 1'b0 On read:
[0]: No interrupt request
[1]: Usage level threshold in read MBOX
On write:
[0]: No acknowledge
[1]: Acknowledge and clear interrupt request
0 WTIRQ R/W 1'b0 On read:
[0]: No interrupt request
[1]: Usage level threshold in write MBOX
On write:
[0]: No acknowledge
[1]: Acknowledge and clear interrupt request

IRQEN Register

Interrupt request enable register. Here the four interrupts from IRQS can be enabled by writing to the corresponding bit in following table.

Bit(s) Name Access Type Reset Value Description
AxiDataWidth-1:3 Reserved Reserved
2 EIRQ R/W 1'b0 [0]: Interrupt request disabled
[1]: Interrupt request enabled
1 RTIRQ R/W 1'b0 [0]: Interrupt request disabled
[1]: Interrupt request enabled
0 WTIRQ R/W 1'b0 [0]: Interrupt request disabled
[1]: Interrupt request enabled

IRQP Register

Interrupt request pending register. This register holds the pending interrupts for this slave port and is read only. It is generated by the bitwise and of the IRQS and IRQEN registers. An interrupt gets triggered by the OR of the bits of this register.

Bit(s) Name Access Type Reset Value Description
AxiDataWidth-1:3 Reserved Reserved
2 EIRQ R 1'b0 [0]: Interrupt request pending
[1]: Error pending
1 RTIRQ R 1'b0 [0]: Interrupt request pending
[1]: MBOX read threshold pending
0 WTIRQ R 1'b0 [0]: Interrupt request pending
[1]: MBOX write threshold pending

CTRL Register

Mailbox control register. Here the FIFOs can be cleared from each interface. The flush signal at each FIFO is the OR combination of the respective bits of this register at each slave port. On register write, the FIFO is cleared and the register is reset.

Bit(s) Name Access Type Reset Value Description
AxiDataWidth-1:2 Reserved Reserved
1 RTIRQ W 1'b0 Flush the read MBOX FIFO for this port
0 WTIRQ W 1'b0 Flush the write MBOX FIFO for this port