A demo running on ESP32-S3 to communicate with USB-HID UPS and to be a tiny NUT (Network UPS Tools) Server.
This is a simple project which contains a USB Host part to communicate with UPS as a HID Device, a protocol_examples_common to connect to specific Wi-Fi, a non-blocking TCP Server to response to work as a tiny NUT server, and a led_strip to control the RGB LED on board.
The UPS HID communication protocol is hard-code for SANTAK TG-BOX 850 (driver.name: usbhid-ups; driver.version.data: MGE HID 1.32
). It may be incompatible with other UPS brands or models.
Some UPS data is hard-code, such as model, serial, vendorid, and so on.
The NUT UPS name is hard-code to be qnapnas
. It will NOT check whether username or password is correct.
Do not use it in production environment, thus it has not been tested and may be stability issues.
KNOWN ISSUES: This little stuff can and will only try to connect to WiFi at booting stage. It will not re-connect to WiFi if it goes offline during the running phase, and you have to press the RST button or de-plug and re-plug the power cable mannually.
(Please ignore the typos on the cover lol)
or https://www.bilibili.com/video/BV1YP411p75y/
- Development board with USB capable ESP SoC and a USB-OTG feature USB Port (or you can DIY a USB Type-A female port with extra 5V power supply). I'm using 源地 ESP32-S3 N16R8 dev board.
- A USB cable for Power supply and programming.
- $1 USB OTG Cable in order to connect to UPS USB port.
Notes for OTG 5V Power Supply:
Some (or most) 3-rd party ESP32-S3 dev boards have a hidden pad (has a USB-OTG label) underneath the board. When it be shorted out, it can provide a 5V source to USB VBUS. more discussions at here.
Otherwise, you have to provide 5V to USB VBUS mannually, such as DIY a USB cable or DIY a USB Type-A female port with extra 5V power supply as below Pin assignments.
ESP BOARD USB CONNECTOR (type A female)
--
| || VCC(Need extra 5V power support!)
[GPIO19] ------> | || D-
[GPIO20] ------> | || D+
| || GND
--
Useful documents && tools
- pdcv11.pdf - Usage Tables for HID Power Devices 1.1
- NUT_MGE_USB_Devices_Draft_AA.pdf
- 51029473zaac.pdf - Simplified SHUT
- Wireshark with USBPcap: To capture USB HID Descriptor and packets.
- Device Monitoring Studio: To send HID packet.
My UPS (SANTAK TG-BOX 850) can be communicated with a QNAP NAS by a USB cable connected. It support a USB HID protocol for Power Device. I plugged it to my PC and got the HID Descriptor by using Wireshark.
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
The USB Host(such as PC or NAS) will send GET_REPORT packet(bRequest=GET_REPORT or 0x01, ReportType = Feature or 3
) timely to UPS, and the UPS will return a bytes buffer contains battery and ups info.
The returned first byte will always be the Report ID.
Report ID: 0x01 (brief information):
- byte[0]: 0x01 - as Report ID
- byte[1]: 0 0 1 0 0 1 0 1
|NeedReplacement: No
|InternalFailure: No
|Good: Yes
|Discharging: No
|CommunicationLost: No
|Charging: Yes
|BelowRemainingCapacityLimit: No
|ACPresent: Yes
- byte[2]: 0x00 - Overload Flag: will gt than 0x00 if overload
- byte[3]: 0x00 - ShutdownImminent Flag: will gt than 0x00 if AC not present and remaining capacity lt remaining capacity limit (20%)
Report ID: 0x06 (battery remaining capacity (in percent) and remaining runtime (in sec)):
- byte[0]: 0x06 - as Report ID
- byte[1]: 0x64 - battery remaining capacity is 100%
- byte[2]: 0xe0
- byte[3]: 0x04
- byte[4]: 0x00
- byte[5]: 0x00 - <00 00 04 e0> as 1248 seconds left for runtime.
Report ID: 0x07 (some IDs and current load (in percent)):
- byte[0]: 0x07 - as Report ID
- byte[1]: 0x02 - other things
- byte[2]: 0x02 - other things
- byte[3]: 0x01 - other things
- byte[4]: 0x00 - other things
- byte[5]: 0x03 - other things
- byte[6]: 0x18 - current load is 24%
- byte[7]: 0x02 - other things
Report ID: 0x08 (remaining capacity limit):
- byte[0]: 0x08 - as Report ID
- byte[1]: 0x14 - remaining capacity limit is 20%
Report ID: 0x0d (config apparent power and config frequency):
- byte[0]: 0x0d - as Report ID
- byte[1]: 0x52
- byte[2]: 0x03 - <03 52> as config apparent power is 850W
- byte[3]: 0x32 - 50Hz as config frequency
Report ID: 0x0e (actual voltage):
- byte[0]: 0x0e - as Report ID
- byte[1]: 0xe6
- byte[2]: 0x00 - <00 e6> as actual voltage is 230V
Report ID: 0x12 (config voltage):
- byte[0]: 0x12 - as Report ID
- byte[1]: 0xdc - as config voltage is 220V
Report ID: 0x13 (allow highest voltage):
- byte[0]: 0x13 - as Report ID
- byte[1]: 0x08
- byte[2]: 0x01 - <01 08> is 264V
Report ID: 0x14 (allow lowest voltage):
- byte[0]: 0x14 - as Report ID
- byte[1]: 0xb8 - is 184V.
Thus the UPS support 184~264V input, and 220V is standard input. Real input voltage is 230V at this time.
Report ID: 0x1f (get (or set) beep sound):
- byte[0]: 0x1f - as Report ID
- byte[1]: 0x02 - beep sound is enabled. 01 is disabled (never sound), and 03 is muted (temporarily silence the alarm). See more by searching AudibleAlarmControl.
You can also use SET_REPORT method to set beep sound. data fragment as 0x1f 0x01
is to disable it.
You can follow the USB HID Class example provided by ESP official. Remember to use the master branch or any future release gt v5.1. The example in v5.1 does not contain hid_class_request_get_report
, and the whole structure is different.
I export the hid_host_device_handle_t
(as latest_hid_device_handle
) object in order to use hid_class_request_get_report
more easily. (The best practice may need to gen a new handle for UPS?)
When it plug in, hid_host_device_event
will be triggered. When it plug out, hid_host_interface_callback
will be triggered. So the UPS_DEV_CONNECTED
flag is changed there. And my UPS hid protocol is none.
a per-1-second timer is set to run refresh_ups_status_from_hid
function if UPS is connected. In that function, hid_class_request_get_report
will be used to gen specific protocol data according to the pre-analize and send to UPS, then get the report contained needed information. It will also update the cJSON object which should contains the latest UPS info and will be sent to NUT clients in TCP-Server part.
set_beep
function will use hid_class_request_set_report
to change the beep status of UPS.
A gptimer is set to trigger at each second. When triggered, it will call timer_on_alarm_callback
. As this function can not run any blocking functions, so it push an element to timer_queue
(also user_ctx
para). The running task timer_task
created by xTaskCreate
can receive this element and do actual things in it, such as refresh_ups_status_from_hid
, change beep status if BOOT_BUTTON is pressed and so on.
A simple way to show some status. The LED shows green if UPS connected, shows orange if UPS disconnected, shows red if UPS has error or AC not present, and shows white if a NUT client ask for data. Search led_strip_set_pixel
in the code file.
This part is as a very simple NUT Server. It can only respond USERNAME
PASSWORD
LOGIN
LIST VAR
GET VAR qnapups ups.status
and LOGOUT
(in tcp_server_task
func). It seems that a NUT client will only ask for these information on a regular basis.
The UPS info is stored as a cJSON object and will be updated at each refresh_ups_status_from_hid
called. When a NUT client ask for info, it will print the cJSON object in a specific format (by calling gen_nut_list_var_text_wrapper
) and return to the client.