eQuest complains about constructions with single layer or with small thickness #6
Comments
I'm going to check the DOE BDL docs; see if it states limits.. probably doesn't but wont hurt to look! |
Thanks. We don't even support doors in Dragonfly right now but having support for the constructions like that makes sense. |
I realized that approx 4 minutes later when I started digging in deeper lol. |
@TfedUD, am I right that this has been resolved already? Should we close this issue? |
@mostaphaRoudsari I'm going to double check and get into cleaning things up and bug hunting today; got caught up on other projects; so back on this to hard press! |
Still needs attention: just need to look up the minimum thickness and implement a check in the mats/cons/layers |
We should use U-VALUE construction in those cases:
The text was updated successfully, but these errors were encountered: