<parameter-file instrument = "BASIS" valid-from = "2011-07-19T00:00:00">
<component-link name = "BASIS">
<parameter name="deltaE-mode" type="string">
<value val="indirect"/>
</parameter>
<!-- Moderator Tzero/LambdaZero Parameters -->
<parameter name="Moderator.TimeZero.Gradient">
<value val="11.967"/>
</parameter>
<parameter name="Moderator.TimeZero.Intercept">
<value val="-5.0"/>
</parameter>
<!-- These properties are necessary for use in the Indirect CTE interface. -->
<parameter name="analysers" type="string">
<value val="silicon,diffraction" />
</parameter>
<parameter name="refl-diffraction" type="string">
<value val="diffonly,diffspec" />
</parameter>
<parameter name="refl-silicon" type="string">
<value val="111,311" />
</parameter>
<!-- Reduction workflow parameters under this line -->
<parameter name="Workflow.Monitor.RebinStep" >
<!-- This is the step size to optionally rebin the monitor to"-->
<value val="10.0" />
</parameter>
<parameter name="Workflow.GroupingMethod" type="string">
<value val="File" />
</parameter>
<parameter name="Workflow.GroupingFile" type="string">
<value val="BASIS_Grouping.xml" />
</parameter>
<parameter name="Workflow.MaskFile" type="string">
<value val="BASIS_Mask.xml" />
</parameter>
<parameter name="Workflow.Monitor1-SpectrumNumber" >
<value val="0" />
</parameter>
<parameter name="Workflow.Monitor1-SpectrumNumber" >
<value val="0" />
</parameter>
<parameter name="Workflow.Monitor1-Area" >
<value val="1.276e-3" />
</parameter>
<parameter name="Workflow.Monitor1-Thickness" >
<value val="0.025" />
</parameter>
<parameter name="Workflow.Monitor1-ScalingFactor">
<value val="1e6" />
</parameter>
<parameter name="Workflow.UnwrapMonitor" type="string">
<value val="BaseOnTimeRegime" />
</parameter>
<parameter name="Workflow.NamingConvention" type="string">
<value val="AnalyserReflection" />
</parameter>
<parameter name="Workflow.SE-log" type="string">
<value val="SensorA" />
</parameter>
<parameter name="Workflow.SE-log-value" type="string">
<value val="average" />
</parameter>
</component-link>