Notifications
You must be signed in to change notification settings - Fork 3
/
Copy pathsimple_mode_multi.py
208 lines (171 loc) · 10 KB
/
simple_mode_multi.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
import instalation_matcher as im
import pandas as pd
import matplotlib.pyplot as plt
for f_set in im.get_installation_sets():
building, heat_pump, water_tank = f_set
building_demand_list_kW = building.get_all_heat_power_list_kW()
temperatures = pd.read_csv('temperatury_2017.csv')['temp'].values.tolist()
hp_heat_power_list_kW = []
hp_compressor_power_list_kW = []
wt_load_level_list_kWh = []
wt_reload_power_list_kW = []
wt_load_power_list_kW = []
electric_heater_list_kW = []
for i in range(len(building_demand_list_kW)):
# Weź aktualne dla godziny:
# - moc pompy ciepła
# - zapotrzebowanie budynku
# - moc kompresora pompy ciepła
# - temperatura otoczenia
# - stan zbiornika
hp_max_heat_power_kW = heat_pump.get_heat_power_kW(temperatures[i])
hp_max_compressor_power_kW = heat_pump.get_compressor_power_kW(temperatures[i])
hp_heat_power_kW = 0
hp_compressor_power_kW = 0
electric_heater_kW = 0
building_demand_kW = building_demand_list_kW[i]
external_temperature = temperatures[i]
wt_load_level_kWh = water_tank.current_state_kWh
wt_load_power_kW = 0
wt_reload_power_kW = 0
if building_demand_kW > 0:
# Czy zbiornik pełny
if water_tank.current_state_kWh >= water_tank.capacity_kWh:
# Wyłącz pompę ciepła i zbiornik.reload()
heat_pump.is_hp_on = False
wt_reload_power_kW = water_tank.reload_tank(building_demand_kW)
wt_load_level_kWh = water_tank.current_state_kWh
wt_load_power_kW = 0
hp_heat_power_kW = 0
hp_compressor_power_kW = 0
electric_heater_kW = 0
else:
# Czy pompa ciepła włączona
if heat_pump.is_hp_on:
# Moc cieplna > Zapotrzebowanie
if hp_max_heat_power_kW > building_demand_kW:
# Ogrzewaj dom
hp_heat_power_kW = building_demand_kW
# Zbiornik.load()
wt_load_power_kW = water_tank.load_tank(hp_max_heat_power_kW - hp_heat_power_kW)
hp_heat_power_kW += wt_load_power_kW
hp_compressor_power_kW = hp_heat_power_kW*hp_max_compressor_power_kW/hp_max_heat_power_kW
electric_heater_kW = 0
wt_reload_power_kW = 0
wt_load_level_kWh = water_tank.current_state_kWh
else:
# Energia w zbiorniku > (Zapotrzebowanie - moc cieplna pompy)
if water_tank.current_state_kWh > (building_demand_kW - hp_max_heat_power_kW):
# Ogrzewaj dom
hp_heat_power_kW = hp_max_heat_power_kW
wt_reload_power_kW = water_tank.reload_tank(building_demand_kW - hp_heat_power_kW )
hp_compressor_power_kW = hp_max_compressor_power_kW
wt_load_power_kW = 0
electric_heater_kW = 0
wt_load_level_kWh = water_tank.current_state_kWh
else:
# Ogrzewaj dom, włącz grzałkę, zbiornik.reload()
hp_heat_power_kW = hp_max_heat_power_kW
wt_reload_power_kW = water_tank.reload_tank(building_demand_kW - hp_heat_power_kW)
hp_compressor_power_kW = hp_max_compressor_power_kW
wt_load_power_kW = 0
electric_heater_kW = building_demand_kW - hp_heat_power_kW - wt_reload_power_kW
wt_load_power_kW = 0
else:
# Energia w zbiorniku > Zapotrzebowanie
if water_tank.current_state_kWh > building_demand_kW:
# Zbiornik.reload()
wt_reload_power_kW = water_tank.reload_tank(building_demand_kW)
wt_load_power_kW = 0
hp_heat_power_kW = 0
hp_compressor_power_kW = 0
electric_heater_kW = 0
wt_load_level_kWh = water_tank.current_state_kWh
else:
# Włącz pompę ciepła
heat_pump.is_hp_on = True
hp_max_heat_power_kW = heat_pump.get_heat_power_kW(temperatures[i])
hp_max_compressor_power_kW = heat_pump.get_compressor_power_kW(temperatures[i])
# Moc cieplna > Zapotrzebowanie - pobór ze zbiornika
if hp_max_heat_power_kW >= building_demand_kW - water_tank.current_state_kWh:
# Ogrzewaj dom, Zbiornik.load()
hp_heat_power_kW = building_demand_kW - water_tank.current_state_kWh
wt_reload_power_kW = water_tank.reload_tank(building_demand_kW - hp_heat_power_kW)
wt_reload_power_kW = 0
wt_load_power_kW = water_tank.load_tank(hp_max_heat_power_kW - hp_heat_power_kW)
wt_load_level_kWh = water_tank.current_state_kWh
hp_heat_power_kW += wt_load_power_kW
hp_compressor_power_kW = hp_heat_power_kW*hp_max_compressor_power_kW/hp_max_heat_power_kW
electric_heater_kW = 0
else:
# Ogrzewaj dom, zbiornik.reload(), włacz grzałkę
hp_heat_power_kW = hp_max_heat_power_kW
hp_compressor_power_kW = hp_max_compressor_power_kW
wt_reload_power_kW = water_tank.reload_tank(water_tank.current_state_kWh)
wt_load_level_kWh = 0
wt_load_power_kW = 0
electric_heater_kW = building_demand_kW - hp_heat_power_kW - wt_reload_power_kW
else:
# Zbiornik.standby()
water_tank.standby()
hp_heat_power_kW = 0
hp_compressor_power_kW = 0
wt_load_level_kWh = water_tank.current_state_kWh
wt_load_power_kW = 0
wt_reload_power_kW = 0
electric_heater_kW = 0
# Zapisz stany budynku, pompy, zbiornika i grzałki
hp_heat_power_list_kW.append(hp_heat_power_kW)
hp_compressor_power_list_kW.append(hp_compressor_power_kW)
wt_load_level_list_kWh.append(wt_load_level_kWh)
wt_load_power_list_kW.append(wt_load_power_kW)
wt_reload_power_list_kW.append(wt_reload_power_kW)
electric_heater_list_kW.append(electric_heater_kW)
# energy_prices = pd.read_csv('prices_year.csv', index_col=[0], parse_dates=[0])
# plt.plot(energy_prices['0'].values)
# plt.plot(wt_load_power_list_kW, 'ro--', label='ładowanie magazynu', markersize=1, linewidth=0.5)
# plt.plot(hp_heat_power_list_kW, 'bo--', label='moc pompy', markersize=1, linewidth=0.5)
# plt.plot(building_demand_list_kW, 'go--', label='zapotrzebowanie budynku', markersize=1, linewidth=0.5)
# plt.plot(wt_load_level_list_kWh, 'co--', label='poziom naładowania kWh', markersize=1, linewidth=0.5)
# plt.plot(electric_heater_list_kW, 'ro--', label='moc grzałki', markersize=4, linewidth=1)
# plt.legend()
# plt.show()
energy_prices = pd.read_csv('prices_year.csv', index_col=[0], parse_dates=[0])
energy_prices_list = energy_prices['0'].values.tolist()
electricity_price = []
electricity_usage_kW = []
for i in range(len(temperatures)):
e_sum = hp_compressor_power_list_kW[i] + electric_heater_list_kW[i]
electricity_usage_kW.append(e_sum)
electricity_price.append(e_sum * energy_prices_list[i] / 1000)
print('Cena w sumie: '+str(sum(electricity_price)))
print(sum(electricity_usage_kW))
print(sum(electric_heater_list_kW))
print('Zapotrzebowanie budynku w sumie: ' + str(sum(building_demand_list_kW)))
fig = plt.figure(figsize=(20, 10))
ax1 = fig.add_axes([0.1, 0.45, 0.8, 0.5], xticklabels=[])
plt.title(
'Dzień w zimie dla budynku - typ: {}, pole: {}, mieszkańcy: {}'.format(
building.type_of_building, building.area, building.people), fontsize=18)
plt.ylabel('Moc [kW]', fontsize=12)
ax2 = fig.add_axes([0.1, 0.1, 0.8, 0.3])
plt.title('Stan napełnienia zbiornika [kWh]', fontsize=18)
plt.xlabel('godziny w roku', fontsize=12)
plt.ylabel('Poziom napełnienia [kWh]', fontsize=12)
ax1.plot(hp_heat_power_list_kW[420:468], 'bo--', label='moc pompy', markersize=4, linewidth=1)
ax1.plot(building_demand_list_kW[420:468], '.-.', color='grey', label='zapotrzebowanie budynku', markersize=4, linewidth=1)
ax1.plot(electric_heater_list_kW[420:468], 'ro--', label='moc grzałki', markersize=4, linewidth=1)
ax1.legend(loc='upper left')
plt.xticks(range(48), range(420, 468), rotation=60)
ax2.plot(wt_load_level_list_kWh[420:468], 'co--', markersize=4, linewidth=1)
# plt.show()
plt.savefig('zdj/zima_1d_bud_{}.png'.format(building.area), dpi=300, inches='tight')
#
# plt.figure(figsize=(20, 10))
# plt.xlabel('godziny w roku', fontsize=12)
# plt.ylabel('Moc cieplna [kW]', fontsize=12)
# plt.title(
# 'Wykorzystanie energii elektrycznej w roku\ntyp budynku: {}, pole powierzchni: {}, ilość mieszkańców: {}'.format(
# building.type_of_building, building.area, building.people), fontsize=18)
# plt.plot(electricity_usage_kW, '.-.', color='grey', label='zapotrzebowanie budynku', markersize=3.5, linewidth=0.5)
# plt.savefig('zdj/elec_usage_{}.png'.format(building.area), dpi=300, inches='tight')