UPS GE LP33 - TriPhase

Description

UPS General Electric - Model LP 33 Trifásica - Cláudio Ferreira

Overview

Zabbix Template for UPS General Electric (GE) Model LP33 Triphase. Works with generic UPS's SNMP v2c enabled too.

Contains most importante items (49), 9 triggers for alerting and 8 graphics.

Because almost OIDs are generic, this template works with other UPS SNMP v2c enabled.

Author

Cláudio Ferreira

Macros used

There are no macros links in this template.

Template links

There are no template links in this template.

Discovery rules

There are no discovery rules in this template.

Items collected

Name Description Type Key and additional info
Input Voltage Min L2

-

SNMP agent upsInputVoltageMin.2

Update: 30s

Output Percent Load L3

-

SNMP agent upsOutputPercentLoad.3

Update: 30s

Bypass Voltage L1

-

SNMP agent upsBypassVoltage.1

Update: 30s

Output Frequency

-

SNMP agent upsOutputFrequency.0

Update: 30s

Inverter Status

-

SNMP agent upsInverterOnOff.0

Update: 30s

Bypass Voltage L2

-

SNMP agent upsBypassVoltage.2

Update: 30s

Input Voltage L1

-

SNMP agent upsInputVoltage.1

Update: 30s

Input Line Bads

-

SNMP agent upsInputLineBads.0

Update: 30s

Battery Status

-

SNMP agent upsBatteryStatus.0

Update: 30s

Output Voltage L1

-

SNMP agent upsOutputVoltage.1

Update: 30s

Operating Time

-

SNMP agent upsIdentOperatingTime.0

Update: 30s

ComProt Version

-

SNMP agent upsIdentComProtVersion.0

Update: 1h

Input Voltage Max L2

-

SNMP agent upsInputVoltageMax.2

Update: 30s

Input Frequency

-

SNMP agent upsInputFrequency.2

Update: 30s

Agent Software Version

-

SNMP agent upsIdentAgentSoftwareVersion.0

Update: 1h

Bypass Status

-

SNMP agent upsBypassOnOff.0

Update: 30s

Output Voltage L3

-

SNMP agent upsOutputVoltage.3

Update: 30s

Output Current L1

-

SNMP agent upsOutputCurrent.1

Update: 30s

Load Source

-

SNMP agent upsLoadSource.0

Update: 30s

Output Voltage L2

-

SNMP agent upsOutputVoltage.2

Update: 30s

Input Voltage Min L3

-

SNMP agent upsInputVoltageMin.3

Update: 30s

Input Num Lines

-

SNMP agent upsInputNumLines.0

Update: 1h

Ups Software Version

-

SNMP agent upsIdentUPSSoftwareVersion.0

Update: 1h

Output Current L3

-

SNMP agent upsOutputCurrent.3

Update: 30s

Input Voltage L3

-

SNMP agent upsInputVoltage.3

Update: 30s

Nome

-

SNMP agent upsIdentName.0

Update: 1h

Battery Temperature

-

SNMP agent upsBatteryTemperature.0

Update: 30s

Output Percent Load L2

-

SNMP agent upsOutputPercentLoad.2

Update: 30s

Input Voltage Min L1

-

SNMP agent upsInputVoltageMin.1

Update: 30s

Battery Charge Method

-

SNMP agent upsBatteryChargeMethod.0

Update: 30s

Bypass Voltage L3

-

SNMP agent upsBypassVoltage.3

Update: 30s

Active Alarms Present

-

SNMP agent upsAlarmsPresent.0

Update: 30s

Output Current L2

-

SNMP agent upsOutputCurrent.2

Update: 30s

Output Num Lines

-

SNMP agent upsOutputNumLines.0

Update: 1h

Input Voltage L2

-

SNMP agent upsInputVoltage.2

Update: 30s

Estimated minutes Remaining

-

SNMP agent upsEstimatedMinutesRemaining.0

Update: 30s

Output Source Presence

"The present source of output power. The enumeration none(2) indicates that there is no source of output power (and therefore no output power), for example, the system has opened the output breaker.(*)"

SNMP agent upsOutputSource.0

Update: 30s

Rectifier Status

-

SNMP agent upsRectifierOnOff.0

Update: 30s

Battery Voltage

-

SNMP agent upsBatteryVoltage.0

Update: 30s

Serial Number

-

SNMP agent upsIdentUPSSerialNumber.0

Update: 1d

UPS Mode

-

SNMP agent upsUPSMode.0

Update: 30s

Estimated Charge Remaining

-

SNMP agent upsEstimatedChargeRemaining.0

Update: 30s

Bypass Frequency

-

SNMP agent upsBypassFrequency.0

Update: 30s

Input Voltage Max L1

-

SNMP agent upsInputVoltageMax.1

Update: 30s

Input Voltage Max L3

-

SNMP agent upsInputVoltageMax.3

Update: 30s

Manufacturer

-

SNMP agent upsIdentManufacturer.0

Update: 1d

Time on Battery

-

SNMP agent upsSecondsOnBattery.0

Update: 30s

Output Percent Load L1

-

SNMP agent upsOutputPercentLoad.1

Update: 30s

Model

-

SNMP agent upsIdentModel.0

Update: 1d

Triggers

There are no triggers in this template.