Eltek Flatpack S

Description

Eltek Flatpack S DC-power system. Template for 2 rectifiers, 1 battery set. No solar power. No wind. No generator. Version 0.3 - Kari Karvonen [email protected] Eltek mibs available ftp://ftp.eltek.com. Ask your dealer or support for username and pass.

Overview

Basic monitoring template for Eltek Flatpack / SmartPack S. 48VDC power system. 2 inverters. One batttery set. No solar power. No generator.

Template is for Zabbix 4.4.0rc1

Items

Power System Company
Power System Site
Power System Model
Power System Serial Number
Rectifiers Temperature Value
Rectifier 1 Input Voltage
Rectifier 2 Input Voltage
Rectifier 1 Output Current Value
Rectifier 2 Output Current Value
Rectifier 1 Status
Rectifier 2 Status
Battery 1 Status
Battery 1 Temperature Value
Battery 1 Total Capacity Value
Battery 1 Voltage Value
Battery 1 Remaining Capacity Value
Battery 1 Current Value
Main Control Unit Temperature Value
Mains Outage Total
Mains Voltage Status L1
Mains Voltage Status L2
Mains Voltage Value L1
Mains Voltage Value L2

Triggers

Lost mains power L1
Lost mains power L2
Battery high temperature
Battery low temperature
Battery 1 low remaining capacity

Author

Kari Karvonen

Macros used

Name Description Default Type
{$BATTERY_CAPACITY_LOW_CRITICAL}

Amper hours capacity left before alarm

5 Text macro
{$BATTERY_TEMP_HIGH_CRITICAL}

-

40 Text macro
{$BATTERY_TEMP_HIGH_WARNING}

-

25 Text macro
{$BATTERY_TEMP_LOW_CRITICAL}

-

-20 Text macro
{$BATTERY_TEMP_LOW_WARNING}

-

0 Text macro
{$SNMP_COMMUNITY}

SNMPv2 read only community

public Text macro

Template links

There are no template links in this template.

Discovery rules

There are no discovery rules in this template.

Items collected

Name Description Type Key and additional info
Rectifier 2 Status

error (0) normal (1) minorAlarm (2) majorAlarm (3) disabled (4) disconnected (5) notPresent (6) minorAndMajor (7) majorLow (8) minorLow (9) majorHigh (10) minorHigh (11) event (12) valueVolt (13) valueAmp (14) valueTemp (15) valueUnit (16) valuePerCent (17) critical (18) warning (19)

SNMP agent rectifierStatus.2

Update: 1m

Load Current Value

-

SNMP agent loadCurrentValue.0

Update: 1m

Rectifier 2 Output Current Value

-

SNMP agent rectifierOutputCurrentValue.2

Update: 1m

Mains Outage Total

-

SNMP agent mainsOutageTotal.0

Update: 1m

Mains Voltage Status L2

error (0) normal (1) minorAlarm (2) majorAlarm (3) disabled (4) disconnected (5) notPresent (6) minorAndMajor (7) majorLow (8) minorLow (9) majorHigh (10) minorHigh (11) event (12) valueVolt (13) valueAmp (14) valueTemp (15) valueUnit (16) valuePerCent (17) critical (18) warning (19)

SNMP agent mainsVoltageStatus.2

Update: 1m

Rectifier 1 Status

error (0) normal (1) minorAlarm (2) majorAlarm (3) disabled (4) disconnected (5) notPresent (6) minorAndMajor (7) majorLow (8) minorLow (9) majorHigh (10) minorHigh (11) event (12) valueVolt (13) valueAmp (14) valueTemp (15) valueUnit (16) valuePerCent (17) critical (18) warning (19)

SNMP agent rectifierStatus.1

Update: 1m

Load 1 Voltage Value

-

SNMP agent loadVoltageValue.1

Update: 1m

Rectifier 2 Input Voltage

-

SNMP agent rectifierInputVoltageValue.2

Update: 1m

Rectifier 1 Output Current Value

-

SNMP agent rectifierOutputCurrentValue.1

Update: 1m

Rectifiers Temperature Value

-

SNMP agent rectifiersTemperatureValue.0

Update: 1m

Battery 1 Total Capacity Value

-

SNMP agent batteryTotalCapacityValue.0

Update: 1h

Mains Status

-

SNMP agent mainsStatus.0

Update: 1m

Output power

-

Calculated LoadOutputPower.0

Update: 1m

Battery 1 Status

error (0) normal (1) minorAlarm (2) majorAlarm (3) disabled (4) disconnected (5) notPresent (6) minorAndMajor (7) majorLow (8) minorLow (9) majorHigh (10) minorHigh (11) event (12) valueVolt (13) valueAmp (14) valueTemp (15) valueUnit (16) valuePerCent (17) critical (18) warning (19)

SNMP agent batteryStatus.0

Update: 1m

Battery 1 Remaining Capacity Value

-

SNMP agent batteryRemainingCapacityValue.0

Update: 1m

Power System Serial Number

-

SNMP agent powerSystemSerialNumber.0

Update: 1h

Main Control Unit Temperature Value

-

SNMP agent mainControlUnitTemperatureValue

Update: 1m

Battery 1 Voltage Value

-

SNMP agent batteryVoltageValue.0

Update: 1m

Mains Voltage Status L1

error (0) normal (1) minorAlarm (2) majorAlarm (3) disabled (4) disconnected (5) notPresent (6) minorAndMajor (7) majorLow (8) minorLow (9) majorHigh (10) minorHigh (11) event (12) valueVolt (13) valueAmp (14) valueTemp (15) valueUnit (16) valuePerCent (17) critical (18) warning (19)

SNMP agent mainsVoltageStatus.1

Update: 1m

Power System Model

-

SNMP agent powerSystemModel.0

Update: 1h

Mains Voltage Value L2

-

SNMP agent mainsVoltageValue.2

Update: 1m

Power System Company

-

SNMP agent powerSystemCompany.0

Update: 1h

Power System Site

-

SNMP agent powerSystemSite.0

Update: 1h

Battery 1 Current Value

-

SNMP agent batteryCurrentsValue.0

Update: 1m

Rectifier 1 Input Voltage

-

SNMP agent rectifierInputVoltageValue.1

Update: 1m

Mains Voltage Value L1

-

SNMP agent mainsVoltageValue.1

Update: 1m

Load Status

-

SNMP agent loadStatus.0

Update: 1m

Power System Status

-

SNMP agent powerSystemStatus.0

Update: 1m

Battery 1 Temperature Value

-

SNMP agent batteryTemperaturesValue.0

Update: 1m