Skip to content

Commit

Permalink
v.1.1
Browse files Browse the repository at this point in the history
1.1 (01/31/2019)
- Fixed toggle for debug messaging.
- Added toggle for trace messaging to avoid log spamming.
- Added toggle for disabling switch in event device is only used for power metering.
- Fixed trace log message that reported old parameter value in the event of a change.
 - Added versioning and naming/link to DTH settings.
 - Added LED control parameter and more options for Instantaneous Power Values parameter.
  • Loading branch information
Madj42 committed Feb 1, 2019
1 parent f755b2f commit 17a8a8b
Showing 1 changed file with 83 additions and 51 deletions.
134 changes: 83 additions & 51 deletions Aeotec_Nano_ZW116.groovy
Original file line number Diff line number Diff line change
Expand Up @@ -6,12 +6,19 @@
* Justin Dybedahl (madj42)
*
* Thanks to Kevin LaFramboise (krlaframboise) for sharing the base DTH (Zooz ZEN15).
*
*
*
* Changelog:
*
* 1.0 (01/28/2019)
* - Initial Release
* 1.1 (01/31/2019)
* - Fixed toggle for debug messaging.
* - Added toggle for trace messaging to avoid log spamming.
* - Added toggle for disabling switch in event device is only used for power metering.
* - Fixed trace log message that reported old parameter value in the event of a change.
* - Added versioning and naming/link to DTH settings.
* - Added LED control parameter and more options for Instantaneous Power Values parameter.
*
*
* Licensed under the Apache License, Version 2.0 (the "License"); you may not use this file except
Expand Down Expand Up @@ -64,10 +71,11 @@ metadata {
simulator { }

preferences {

configParams?.each {
getOptionsInput(it)
}
input "energyPrice", "decimal",
title: "\$/kWh Cost:",
defaultValue: energyPriceSetting,
Expand All @@ -84,7 +92,12 @@ metadata {
getBoolInput("display${it}", "Display ${it} Activity", true)
}

getBoolInput("debugOutput", "Enable Debug Logging", true)
getBoolInput("disableSwitch", "Disable On/Off Switch", false)
getBoolInput("traceOutput", "Enable Trace Logging", false)
getBoolInput("debugOutput", "Enable Debug Logging", false)

input title: "", description: "Aeotec Nano Switch w/ Power Metering v${clientVersion()}", displayDuringSetup: false, type: "paragraph", element: "paragraph", required: true
input title: "", description: "http://www.github.com/Madj42/SmartThings-ZW116", displayDuringSetup: false, type: "paragraph", element: "paragraph"
}

tiles(scale: 2) {
Expand Down Expand Up @@ -127,6 +140,10 @@ metadata {
}
}

def clientVersion() {
return "1.1"
}

private getOptionsInput(param) {
if (param.prefName) {
input "${param.prefName}", "enum",
Expand Down Expand Up @@ -203,10 +220,11 @@ def configure() {
}

private updateConfigVal(param) {
def cmds = []
def cmds = []
if (hasPendingChange(param)) {
def oldVal = getParamStoredIntVal(param)
def newVal = getParamIntVal(param)
log.trace "${param.name}(#${param.num}): changing ${getParamStoredIntVal(param)} to ${newVal}"
logTrace "${param.name}(#${param.num}): changing ${getParamStoredIntVal(param)} to ${newVal}"
cmds << configSetCmd(param, newVal)
cmds << configGetCmd(param)
}
Expand Down Expand Up @@ -234,29 +252,33 @@ void updateHealthCheckInterval() {
}

def ping() {
log.debug "Pinging device because it has not checked in"
logDebug "Pinging device because it has not checked in"
return [switchBinaryGetCmd()]
}


def on() {
log.trace "Turning On"
logTrace "Turning On"
return delayBetweenCmds([
switchBinarySetCmd(0xFF),
switchBinaryGetCmd()
])
}

def off() {
log.trace "Turning Off"
return delayBetweenCmds([
switchBinarySetCmd(0x00),
switchBinaryGetCmd()
])
if (disableSwitchSetting) {
logTrace "Switch is disabled"
} else {
logTrace "Turning Off"
return delayBetweenCmds([
switchBinarySetCmd(0x00),
switchBinaryGetCmd()
])
}
}

def refresh() {
log.trace "Refreshing"
logTrace "Refreshing"
return delayBetweenCmds([
switchBinaryGetCmd(),
meterGetCmd(meterEnergy),
Expand All @@ -267,7 +289,7 @@ def refresh() {
}

def reset() {
log.trace "Resetting"
logTrace "Resetting"
["power", "voltage", "current"].each {
sendEvent(createEventMap("${it}Low", getAttrVal(it), false))
sendEvent(createEventMap("${it}High", getAttrVal(it), false))
Expand Down Expand Up @@ -383,7 +405,7 @@ def zwaveEvent(physicalgraph.zwave.commands.configurationv2.ConfigurationReport

if (configParam) {
def name = configParam.options?.find { it.value == val}?.key
//log.Debug "${configParam.name}(#${configParam.num}) = ${name != null ? name : val} (${val})"
logDebug "${configParam.name}(#${configParam.num}) = ${name != null ? name : val} (${val})"
state["configVal${cmd.parameterNumber}"] = val

// if (configParam.num == overloadProtectionParam.num) {
Expand All @@ -392,32 +414,32 @@ def zwaveEvent(physicalgraph.zwave.commands.configurationv2.ConfigurationReport

}
else {
log.debug "Parameter ${cmd.parameterNumber} = ${val}"
logDebug "Parameter ${cmd.parameterNumber} = ${val}"
}
return []
}

def zwaveEvent(physicalgraph.zwave.commands.versionv1.VersionReport cmd) {
log.Trace "VersionReport: ${cmd}"
logTrace "VersionReport: ${cmd}"

def version = "${cmd.applicationVersion}.${cmd.applicationSubVersion}"

if (version != device.currentValue("firmwareVersion")) {
log.Debug "Firmware: ${version}"
logDebug "Firmware: ${version}"
sendEvent(name: "firmwareVersion", value: version, displayed:false)
}
return []
}

def zwaveEvent(physicalgraph.zwave.commands.switchbinaryv1.SwitchBinaryReport cmd) {
log.trace "SwitchBinaryReport: ${cmd}"
logTrace "SwitchBinaryReport: ${cmd}"
def result = []
result << createSwitchEvent(cmd.value, "digital")
return result
}

def zwaveEvent(physicalgraph.zwave.commands.basicv1.BasicReport cmd) {
log.trace "BasicReport: ${cmd}"
logTrace "BasicReport: ${cmd}"
def result = []
result << createSwitchEvent(cmd.value, "physical")
return result
Expand All @@ -431,7 +453,7 @@ private createSwitchEvent(value, type) {
}

def zwaveEvent(physicalgraph.zwave.commands.meterv3.MeterReport cmd) {
log.trace "MeterReport: $cmd"
logTrace "MeterReport: $cmd"
def result = []
def val = roundTwoPlaces(cmd.scaledMeterValue)

Expand All @@ -451,7 +473,7 @@ def zwaveEvent(physicalgraph.zwave.commands.meterv3.MeterReport cmd) {
meter = meterCurrent
break
default:
log.debug "Unknown Meter Scale: $cmd"
logDebug "Unknown Meter Scale: $cmd"
}

if (meter?.limit && val > meter.limit) {
Expand Down Expand Up @@ -550,9 +572,9 @@ def refreshHistory() {
items["${it}High"] = "${it.capitalize()} - High"
}

if (getParamStoredIntVal(overloadProtectionParam) == 0) {
history += "*** Overload Protection Disabled ***\n"
}
// if (getParamStoredIntVal(overloadProtectionParam) == 0) {
// history += "*** Overload Protection Disabled ***\n"
// }

items.each { attrName, caption ->
def attr = device.currentState("${attrName}")
Expand All @@ -564,7 +586,7 @@ def refreshHistory() {
}

def zwaveEvent(physicalgraph.zwave.Command cmd) {
log.debug "Unhandled zwaveEvent: $cmd"
logDebug "Unhandled zwaveEvent: $cmd"
return []
}

Expand All @@ -575,7 +597,7 @@ private getConfigParams() {
instantPowerValuesParam,
instantPowerFrequencyParam,
// onOffNotificationsParam,
// ledIndicatorParam,
ledIndicatorParam,
// powerValueChangeParam,
// powerPercentageChangeParam,
// powerReportIntervalParam,
Expand All @@ -586,28 +608,28 @@ private getConfigParams() {
}

private getInstantPowerValuesParam() {
return createConfigParamMap(101, "Instantaneous Power Report Return", 4, ["All${defaultOptionSuffix}":15, "kWh/Watt":3], "instantPowerValues")
return createConfigParamMap(101, "Instantaneous Power Report Values", 4, ["Current":8, "kWh/Watt":9, "Current/Watt":10, "Current/Watt/kWh":11, "Current/Voltage":12, "Current/Voltage/kWh":13, "Current/Voltage/Watt":14, "All${defaultOptionSuffix}":15], "instantPowerValues")
}

private getinstantPowerFrequencyParam() {
return createConfigParamMap(111, "Instantaneous Power Report Frequency", 4, ["10 Seconds${defaultOptionSuffix}":10, "30 Seconds":30, "1 Minute":60, "2 Minutes":120, "5 Minutes":300], "instantPowerFrequency")
return createConfigParamMap(111, "Instantaneous Power Report Frequency", 4, ["10 Seconds":10, "30 Seconds${defaultOptionSuffix}":30, "1 Minute":60, "2 Minutes":120, "5 Minutes":300], "instantPowerFrequency")
}

private getOnOffNotificationsParam() {
return createConfigParamMap(24, "On/Off Notifications", 1, null, null, 2) // 2:Manual switch only
}
//private getOnOffNotificationsParam() {
// return createConfigParamMap(24, "On/Off Notifications", 1, null, null, 2) // 2:Manual switch only
//}

private getLedIndicatorParam() {
return createConfigParamMap(27, "LED Power Consumption Indicator", 1, ["Always Show${defaultOptionSuffix}":0, "Show for 5 seconds when turned on or off":1], "ledIndicator")
return createConfigParamMap(83, "LED Power Indicator", 1, ["Follow the status of load (Energy mode)${defaultOptionSuffix}":0, "Follow the status (on/off) of load. Red LED turns off after 5 sec if no change (Momentary indicate mode)":1], "ledIndicator")
}

private getPowerValueChangeParam() {
return createConfigParamMap(151, "Power Report Value Change", 2, getPowerValueOptions(), "powerValueChange")
}
//private getPowerValueChangeParam() {
// return createConfigParamMap(151, "Power Report Value Change", 2, getPowerValueOptions(), "powerValueChange")
//}

private getPowerPercentageChangeParam() {
return createConfigParamMap(152, "Power Report Percentage Change", 1, getPercentageOptions(10, "No Reports"), "powerPercentageChange")
}
//private getPowerPercentageChangeParam() {
// return createConfigParamMap(152, "Power Report Percentage Change", 1, getPercentageOptions(10, "No Reports"), "powerPercentageChange")
//}

private getPowerReportIntervalParam() {
return createConfigParamMap(171, "Power Reporting Interval", 4, getIntervalOptions(30, "No Reports"), "powerReportingInterval")
Expand All @@ -626,7 +648,7 @@ private getElectricityReportIntervalParam() {
}

private getParamStoredIntVal(param) {
//return state["configVal${param.num}"]
return state["configVal${param.num}"]
}

private getParamIntVal(param) {
Expand Down Expand Up @@ -660,6 +682,14 @@ private getDebugOutputSetting() {
return settings?.debugOutput != false
}

private getTraceOutputSetting() {
return settings?.traceOutput != false
}

private getDisableSwitchSetting() {
return settings?.disableSwitch != false
}

private getMinimumReportingInterval() {
def minVal = (60 * 60 * 24 * 7)
[powerReportIntervalParam, energyReportIntervalParam, voltageReportIntervalParam, electricityReportIntervalParam].each {
Expand Down Expand Up @@ -771,11 +801,11 @@ private createEventMap(name, value, displayed=null, desc=null, unit=null) {
}

if (desc && eventMap.displayed) {
log.debug desc
logDebug desc
eventMap.descriptionText = "${device.displayName} - ${desc}"
}
else {
log.trace "Creating Event: ${eventMap}"
logTrace "Creating Event: ${eventMap}"
}
return eventMap
}
Expand All @@ -785,7 +815,7 @@ private getAttrVal(attrName) {
return device?.currentValue("${attrName}")
}
catch (ex) {
log.trace "$ex"
logTrace "$ex"
return null
}
}
Expand Down Expand Up @@ -816,12 +846,14 @@ private isDuplicateCommand(lastExecuted, allowedMil) {
!lastExecuted ? false : (lastExecuted + allowedMil > new Date().time)
}

//private logDebug(msg) {
// if (debugOutputSetting) {
// log.debug "$msg"
// }
//}
private logDebug(msg) {
if (debugOutputSetting) {
log.debug "$msg"
}
}

//private logtrace(msg) {
// // log.trace "$msg"
//}
private logTrace(msg) {
if (traceOutputSetting) {
log.trace "$msg"
}
}

0 comments on commit 17a8a8b