ovs-openflowd: Standardize on OpenFlow description option
Browse files Browse the repository at this point in the history
ovs-vswitchd used a slightly different way to set the manufacturer,
hardware revision, software revision, serial number, and datapath
description than ovs-openflowd.  This standardizes on the ovs-vswitch
style and describes how to use them in the man page.
  • Loading branch information
Justin Pettit committed Feb 20, 2010
1 parent 23ff282 commit 0c30c8f
Show file tree
Hide file tree
Showing 2 changed files with 65 additions and 18 deletions.
47 changes: 47 additions & 0 deletions utilities/ovs-openflowd.8.in
Original file line number Diff line number Diff line change
Expand Up @@ -155,6 +155,53 @@ the local port network device, and start the DHCP client afterward.
.RE

.SH OPTIONS
.SS "OpenFlow Options"
.TP
\fB--datapath-id=\fIdpid\fR
Sets \fIdpid\fR, which must consist of exactly 16 hexadecimal digits,
as the datapath ID that the switch will use to identify itself to the
OpenFlow controller.

If this option is omitted, the default datapath ID is taken from the
Ethernet address of the datapath's local port (which is typically
randomly generated) in the lower 48 bits and zeros in the upper 16.

.TP
\fB--mgmt-id=\fImgmtid\fR
Sets \fImgmtid\fR, which must consist of exactly 12 hexadecimal
digits, as the switch's management ID.

If this option is omitted, the management ID defaults to 0, signaling
to the controller that management is supported but not configured.

.TP
\fB--mfr-desc=\fIdesc\fR
Set the description of the switch's manufacturer to \fIdesc\fR, which
may contain up to 255 ASCII characters.

.TP
\fB--hw-desc=\fIdesc\fR
Set the description of the switch's hardware revision to \fIdesc\fR, which
may contain up to 255 ASCII characters.

.TP
\fB--sw-desc=\fIdesc\fR
Set the description of the switch's software revision to \fIdesc\fR, which
may contain up to 255 ASCII characters.

.TP
\fB--serial-desc=\fIdesc\fR
Set the description of the switch's serial number to \fIdesc\fR, which
may contain up to 31 ASCII characters.

.TP
\fB--dp-desc=\fIdesc\fR
Set the description of the datapath to \fIdesc\fR, which may contain up to
255 ASCII characters. Note that this field is intended for debugging
purposes and is not guaranteed to be unique and should not be used as
the primary identifier of the datapath.


.SS "Controller Discovery Options"
.TP
\fB--accept-vconn=\fIregex\fR
Expand Down
36 changes: 18 additions & 18 deletions utilities/ovs-openflowd.c
Original file line number Diff line number Diff line change
Expand Up @@ -240,10 +240,10 @@ parse_options(int argc, char *argv[], struct ofsettings *s)
{
enum {
OPT_DATAPATH_ID = UCHAR_MAX + 1,
OPT_MANUFACTURER,
OPT_HARDWARE,
OPT_SOFTWARE,
OPT_SERIAL,
OPT_MFR_DESC,
OPT_HW_DESC,
OPT_SW_DESC,
OPT_SERIAL_DESC,
OPT_DP_DESC,
OPT_ACCEPT_VCONN,
OPT_NO_RESOLV_CONF,
Expand All @@ -268,11 +268,11 @@ parse_options(int argc, char *argv[], struct ofsettings *s)
};
static struct option long_options[] = {
{"datapath-id", required_argument, 0, OPT_DATAPATH_ID},
{"manufacturer", required_argument, 0, OPT_MANUFACTURER},
{"hardware", required_argument, 0, OPT_HARDWARE},
{"software", required_argument, 0, OPT_SOFTWARE},
{"serial", required_argument, 0, OPT_SERIAL},
{"dp_desc", required_argument, 0, OPT_DP_DESC},
{"mfr-desc", required_argument, 0, OPT_MFR_DESC},
{"hw-desc", required_argument, 0, OPT_HW_DESC},
{"sw-desc", required_argument, 0, OPT_SW_DESC},
{"serial-desc", required_argument, 0, OPT_SERIAL_DESC},
{"dp-desc", required_argument, 0, OPT_DP_DESC},
{"accept-vconn", required_argument, 0, OPT_ACCEPT_VCONN},
{"no-resolv-conf", no_argument, 0, OPT_NO_RESOLV_CONF},
{"config", required_argument, 0, 'F'},
Expand Down Expand Up @@ -342,19 +342,19 @@ parse_options(int argc, char *argv[], struct ofsettings *s)
}
break;

case OPT_MANUFACTURER:
case OPT_MFR_DESC:
s->mfr_desc = optarg;
break;

case OPT_HARDWARE:
case OPT_HW_DESC:
s->hw_desc = optarg;
break;

case OPT_SOFTWARE:
case OPT_SW_DESC:
s->sw_desc = optarg;
break;

case OPT_SERIAL:
case OPT_SERIAL_DESC:
s->serial_desc = optarg;
break;

Expand Down Expand Up @@ -531,11 +531,11 @@ usage(void)
printf("\nOpenFlow options:\n"
" -d, --datapath-id=ID Use ID as the OpenFlow switch ID\n"
" (ID must consist of 16 hex digits)\n"
" --manufacturer=MFR Identify manufacturer as MFR\n"
" --hardware=HW Identify hardware as HW\n"
" --software=SW Identify software as SW\n"
" --serial=SERIAL Identify serial number as SERIAL\n"
" --dp_desc=DP_DESC Identify dp description as DP_DESC\n"
" --mfr-desc=MFR Identify manufacturer as MFR\n"
" --hw-desc=HW Identify hardware as HW\n"
" --sw-desc=SW Identify software as SW\n"
" --serial-desc=SERIAL Identify serial number as SERIAL\n"
" --dp-desc=DP_DESC Identify dp description as DP_DESC\n"
"\nController discovery options:\n"
" --accept-vconn=REGEX accept matching discovered controllers\n"
" --no-resolv-conf do not update /etc/resolv.conf\n"
Expand Down

0 comments on commit 0c30c8f