Alphabetize configuration options in the ts2phc man page.
Browse files Browse the repository at this point in the history
Signed-off-by: Richard Cochran <[email protected]>
  • Loading branch information
richardcochran committed Feb 17, 2023
1 parent d262de5 commit 64f016e
Showing 1 changed file with 23 additions and 10 deletions.
33 changes: 23 additions & 10 deletions ts2phc.8
Original file line number Diff line number Diff line change
Expand Up @@ -124,12 +124,14 @@ changing the clock frequency (phase when using nullf servo) instead of stepping
the clock. This is only applied on the first update. When set to 0.0, the servo
will not step the clock on start.
The default is 0.00002 (20 microseconds).

.TP
.B free_running
When set to 1, no PHC will be adjusted.
This option can be useful in test scenarios, for example to determine
how well synchronized a group of local clocks are to each other.
The default is 0 (adjust the clocks).

.TP
.B leapfile
The path to the current leap seconds definition file. In a Debian
Expand All @@ -138,44 +140,40 @@ system this file is provided by the tzdata package and can be found at
will be reloaded if modified. The default is an empty string, which
causes the program to use a hard coded table that reflects the known
leap seconds on the date of the software's release.

.TP
.B logging_level
The maximum logging level of messages which should be printed.
The default is 6 (LOG_INFO).

.TP
.B max_frequency
The maximum allowed frequency adjustment of the clock in parts per
billion. This is an additional limit to the maximum allowed by the
hardware. When set to 0, the hardware limit will be used.
The default is 900000000 (90%).

.TP
.B message_tag
The tag which is added to all messages printed to the standard output
or system log. The default is an empty string (which cannot be set in
the configuration file as the option requires an argument).

.TP
.B step_threshold
The maximum offset, specified in seconds, that the servo will correct
by changing the clock frequency instead of stepping the clock. When
set to 0.0, the servo will never step the clock except on start.
The default is 0.0.
.TP
.B ts2phc.tod_source
Specifies the source of Time of Day (ToD) data.
Use the key word "generic" for an external 1-PPS without ToD information.
When using a PHC as the time source, the clock may be identified by its character
device (like /dev/ptp0) or its associated network interface (like
eth0).
Use the key word "nmea" for an external 1-PPS from a GPS providing ToD
information via the RMC NMEA sentence.
The default is "generic"

.TP
.B ts2phc.nmea_remote_host, ts2phc.nmea_remote_port
Specifies the remote host providing ToD information when using the
"nmea" PPS signal source. Note that if these two options are both
specified, then the given remote connection will be used in preference
to the configured serial port.
These options default to the empty string, that is, not specified.

.TP
.B ts2phc.nmea_serialport, ts2phc.nmea_baudrate
Specifies the serial port and baudrate in bps for character device
Expand All @@ -185,6 +183,7 @@ ts2phc.nmea_remote_port, are both specified, then the given remote
connection will be used in preference to the configured serial port.
The default serial port is "/dev/ttyS0".
The default baudrate is 9600 bps.

.TP
.B ts2phc.perout_phase
Configures the offset between the beginning of the second and the PPS
Expand All @@ -195,6 +194,7 @@ instead PPS will be requested to start at an absolute time equal to the
nearest 2nd full second since the start of the program. This should yield
the same effect, but may not work with drivers that do not support
starting periodic output at an absolute time.

.TP
.B ts2phc.pulsewidth
The pulse width of the external PPS signal in nanoseconds.
Expand All @@ -205,9 +205,22 @@ emit using this pulse width. If this fails, it is assumed that the specified
pulse width is correct, and the value is used in the edge rejection algorithm.
The supported range is 1000000 to 990000000 nanoseconds.
The default is 500000000 nanoseconds.

.TP
.B ts2phc.tod_source
Specifies the source of Time of Day (ToD) data.
Use the key word "generic" for an external 1-PPS without ToD information.
When using a PHC as the time source, the clock may be identified by its character
device (like /dev/ptp0) or its associated network interface (like
eth0).
Use the key word "nmea" for an external 1-PPS from a GPS providing ToD
information via the RMC NMEA sentence.
The default is "generic"

.TP
.B use_syslog
Print messages to the system log if enabled. The default is 1 (enabled).

.TP
.B verbose
Print messages to the standard output if enabled. The default is 0 (disabled).