DevWs for SHINA SYSTEM containing containing Zigbee Power Meter (Smar…
…tThingsCommunity#77282) * DevWs for SHINA SYSTEM containing containing Zigbee Power Meter * Update sihas-zigbee-power-meter.groovy fix indentation * Update sihas-zigbee-power-meter.groovy Energy min reporting : 1 -> 5 seconds * Update sihas-zigbee-power-meter.groovy Fix indentations. * Update sihas-zigbee-power-meter.groovy add space after if
- Loading branch information
Showing
1 changed file
with
162 additions
and
0 deletions.
There are no files selected for viewing
162 changes: 162 additions & 0 deletions
162
devicetypes/shinasys/sihas-zigbee-power-meter.src/sihas-zigbee-power-meter.groovy
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,162 @@ | ||
/** | ||
* Copyright 2022 SmartThings | ||
* | ||
* Licensed under the Apache License, Version 2.0 (the "License"); you may not use this file except | ||
* in compliance with the License. You may obtain a copy of the License at: | ||
* | ||
* http://www.apache.org/licenses/LICENSE-2.0 | ||
* | ||
* Unless required by applicable law or agreed to in writing, software distributed under the License is distributed | ||
* on an "AS IS" BASIS, WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. See the License | ||
* for the specific language governing permissions and limitations under the License. | ||
* | ||
*/ | ||
import physicalgraph.zigbee.zcl.DataType | ||
|
||
metadata { | ||
definition (name: "SiHAS Zigbee Power Meter", namespace: "shinasys", author: "SHINA SYSTEM", mnmn: "SmartThingsCommunity", ocfDeviceType: "x.com.st.d.energymeter", vid: "92543bd9-8a3c-3c8a-b43a-036a6a4bea9d") { | ||
capability "Energy Meter" | ||
capability "Power Meter" | ||
capability "Refresh" | ||
capability "Health Check" | ||
capability "Sensor" | ||
capability "Configuration" | ||
capability "Voltage Measurement" | ||
capability "afterguide46998.currentMeasurement" | ||
capability "afterguide46998.frequencyMeasurement" | ||
capability "afterguide46998.powerfactorMeasurement" | ||
capability "Temperature Measurement" | ||
|
||
fingerprint profileId: "0104", manufacturer: "ShinaSystem", model: "PMM-300Z2", deviceJoinName: "SiHAS Energy Monitor" // Single Phase, SIHAS Power Meter 01 0104 0000 01 06 0000 0004 0003 0B04 0702 0402 02 0004 0019 | ||
fingerprint profileId: "0104", manufacturer: "ShinaSystem", model: "PMM-300Z3", deviceJoinName: "SiHAS Energy Monitor" // Three Phase, SIHAS Power Meter 01 0104 0000 01 06 0000 0004 0003 0B04 0702 0402 02 0004 0019 | ||
} | ||
} | ||
|
||
def getATTRIBUTE_READING_INFO_SET() { 0x0000 } | ||
def getATTRIBUTE_HISTORICAL_CONSUMPTION() { 0x0400 } | ||
def getATTRIBUTE_ACTIVE_POWER() { 0x050B } | ||
def getATTRIBUTE_FREQUENCY() { 0x0300 } | ||
def getATTRIBUTE_VOLTAGE() { 0x0505 } | ||
def getATTRIBUTE_CURRENT() { 0x0508 } | ||
def getATTRIBUTE_POWERFACTOR() { 0x0510 } | ||
def getTEMPERATURE_MEASUREMENT_MEASURED_VALUE_ATTRIBUTE() { 0x0000 } | ||
|
||
def convertHexToInt24Bit(value) { | ||
int result = zigbee.convertHexToInt(value) | ||
if (result & 0x800000) { | ||
result |= 0xFF000000 | ||
} | ||
return result | ||
} | ||
|
||
def parse(String description) { | ||
log.debug "description is $description" | ||
if (description?.startsWith('temperature:')) { //parse temperature | ||
List result = [] | ||
def map = [:] | ||
map.name = description.split(": ")[0] | ||
map.value = description.split(": ")[1] | ||
map.unit = getTemperatureScale() | ||
log.debug "${device.displayName}: Reported temperature is ${map.value}°$map.unit" | ||
return createEvent(map) | ||
} else { | ||
List result = [] | ||
def descMap = zigbee.parseDescriptionAsMap(description) | ||
log.debug "Desc Map: $descMap" | ||
|
||
List attrData = [[clusterInt: descMap.clusterInt ,attrInt: descMap.attrInt, value: descMap.value, isValidForDataType: descMap.isValidForDataType]] | ||
descMap.additionalAttrs.each { | ||
attrData << [clusterInt: descMap.clusterInt, attrInt: it.attrInt, value: it.value, isValidForDataType: it.isValidForDataType] | ||
} | ||
attrData.each { | ||
def map = [:] | ||
if (it.isValidForDataType && (it.value != null)) { | ||
if (it.clusterInt == zigbee.SIMPLE_METERING_CLUSTER && it.attrInt == ATTRIBUTE_HISTORICAL_CONSUMPTION) { | ||
log.debug "meter" | ||
map.name = "power" | ||
map.value = convertHexToInt24Bit(it.value)/powerDivisor | ||
map.unit = "W" | ||
} else if (it.clusterInt == zigbee.SIMPLE_METERING_CLUSTER && it.attrInt == ATTRIBUTE_READING_INFO_SET) { | ||
log.debug "energy" | ||
map.name = "energy" | ||
map.value = zigbee.convertHexToInt(it.value)/energyDivisor | ||
map.unit = "kWh" | ||
} else if (it.clusterInt == zigbee.ELECTRICAL_MEASUREMENT_CLUSTER && it.attrInt == ATTRIBUTE_FREQUENCY) { | ||
log.debug "frequency" | ||
map.name = "frequency" | ||
map.value = zigbee.convertHexToInt(it.value)/frequencyDivisor | ||
map.unit = "Hz" | ||
} else if (it.clusterInt == zigbee.ELECTRICAL_MEASUREMENT_CLUSTER && it.attrInt == ATTRIBUTE_VOLTAGE) { | ||
log.debug "voltage" | ||
map.name = "voltage" | ||
map.value = zigbee.convertHexToInt(it.value)/voltageDivisor | ||
map.unit = "V" | ||
} else if (it.clusterInt == zigbee.ELECTRICAL_MEASUREMENT_CLUSTER && it.attrInt == ATTRIBUTE_CURRENT) { | ||
log.debug "current" | ||
map.name = "current" | ||
map.value = zigbee.convertHexToInt(it.value)/currentDivisor | ||
map.unit = "A" | ||
} else if (it.clusterInt == zigbee.ELECTRICAL_MEASUREMENT_CLUSTER && it.attrInt == ATTRIBUTE_POWERFACTOR) { | ||
log.debug "power factor $it.value" | ||
map.name = "powerFactor" | ||
map.value = (byte) zigbee.convertHexToInt(it.value)/powerFactorDivisor | ||
map.unit = "%" | ||
} else if (it.clusterInt == zigbee.TEMPERATURE_MEASUREMENT_CLUSTER && it.attrInt == TEMPERATURE_MEASUREMENT_MEASURED_VALUE_ATTRIBUTE) { | ||
log.debug "temperature" | ||
map.name = "temperature" | ||
map.unit = getTemperatureScale() | ||
map.value = zigbee.parseHATemperatureValue("temperature: " + (zigbee.convertHexToInt(it.value)), "temperature: ", tempScale) | ||
log.debug "${device.displayName}: Reported temperature is ${map.value}°$map.unit" | ||
} | ||
} | ||
|
||
if (map) { | ||
result << createEvent(map) | ||
} | ||
log.debug "Parse returned $map" | ||
} | ||
return result | ||
} | ||
} | ||
|
||
/** | ||
* PING is used by Device-Watch in attempt to reach the Device | ||
* */ | ||
def ping() { | ||
return refresh() | ||
} | ||
|
||
def refresh() { | ||
log.debug "refresh " | ||
zigbee.simpleMeteringPowerRefresh() + | ||
zigbee.readAttribute(zigbee.SIMPLE_METERING_CLUSTER, ATTRIBUTE_READING_INFO_SET) + | ||
zigbee.readAttribute(zigbee.ELECTRICAL_MEASUREMENT_CLUSTER, ATTRIBUTE_FREQUENCY) + | ||
zigbee.readAttribute(zigbee.ELECTRICAL_MEASUREMENT_CLUSTER, ATTRIBUTE_VOLTAGE) + | ||
zigbee.readAttribute(zigbee.ELECTRICAL_MEASUREMENT_CLUSTER, ATTRIBUTE_CURRENT) + | ||
zigbee.readAttribute(zigbee.ELECTRICAL_MEASUREMENT_CLUSTER, ATTRIBUTE_POWERFACTOR) + | ||
zigbee.readAttribute(zigbee.TEMPERATURE_MEASUREMENT_CLUSTER, TEMPERATURE_MEASUREMENT_MEASURED_VALUE_ATTRIBUTE) | ||
} | ||
|
||
def configure() { | ||
def configCmds = [] | ||
// this device will send instantaneous demand and current summation delivered every 1 minute | ||
sendEvent(name: "checkInterval", value: 2 * 60 + 10 * 60, displayed: false, data: [protocol: "zigbee", hubHardwareId: device.hub.hardwareID]) | ||
|
||
log.debug "Configuring Reporting" | ||
configCmds = zigbee.simpleMeteringPowerConfig() + | ||
zigbee.configureReporting(zigbee.SIMPLE_METERING_CLUSTER, ATTRIBUTE_READING_INFO_SET, DataType.UINT48, 5, 600, 1) + | ||
zigbee.configureReporting(zigbee.ELECTRICAL_MEASUREMENT_CLUSTER, ATTRIBUTE_FREQUENCY, DataType.UINT16, 10, 600, 3) + /* 3 unit : 0.3Hz */ | ||
zigbee.configureReporting(zigbee.ELECTRICAL_MEASUREMENT_CLUSTER, ATTRIBUTE_VOLTAGE, DataType.UINT16, 5, 600, 3) + /* 3 unit : 0.3V */ | ||
zigbee.configureReporting(zigbee.ELECTRICAL_MEASUREMENT_CLUSTER, ATTRIBUTE_CURRENT, DataType.UINT16, 5, 600, 1) + /* 1 unit : 0.01A */ | ||
zigbee.configureReporting(zigbee.ELECTRICAL_MEASUREMENT_CLUSTER, ATTRIBUTE_POWERFACTOR, DataType.INT8, 10, 600, 1) + /* 1 unit : 0.1% */ | ||
zigbee.configureReporting(zigbee.TEMPERATURE_MEASUREMENT_CLUSTER, TEMPERATURE_MEASUREMENT_MEASURED_VALUE_ATTRIBUTE, DataType.INT16, 20, 300, 10 /* 1 uint : 0.1C */) | ||
return configCmds + refresh() | ||
} | ||
|
||
private getActivePowerDivisor() { 1 } | ||
private getPowerDivisor() { 1 } | ||
private getEnergyDivisor() { 1000 } | ||
private getFrequencyDivisor() { 10 } | ||
private getVoltageDivisor() { 10 } | ||
private getCurrentDivisor() { 100 } | ||
private getPowerFactorDivisor() { 1 } |