Skip to content

Commit

Permalink
power: supply: sbs-battery: add POWER_SUPPLY_HEALTH_CALIBRATION_REQUI…
Browse files Browse the repository at this point in the history
…RED support

Add support for reporting the SBS battery's condition flag
to userspace using the new "Calibration required" health status.

Reviewed-by: Emil Velikov <[email protected]>
Signed-off-by: Sebastian Reichel <[email protected]>
  • Loading branch information
sre committed May 28, 2020
1 parent 7721c2f commit 6f72a07
Showing 1 changed file with 24 additions and 3 deletions.
27 changes: 24 additions & 3 deletions drivers/power/supply/sbs-battery.c
Original file line number Diff line number Diff line change
Expand Up @@ -23,6 +23,7 @@

enum {
REG_MANUFACTURER_DATA,
REG_BATTERY_MODE,
REG_TEMPERATURE,
REG_VOLTAGE,
REG_CURRENT_NOW,
Expand Down Expand Up @@ -94,6 +95,8 @@ static const struct chip_data {
} sbs_data[] = {
[REG_MANUFACTURER_DATA] =
SBS_DATA(POWER_SUPPLY_PROP_PRESENT, 0x00, 0, 65535),
[REG_BATTERY_MODE] =
SBS_DATA(-1, 0x03, 0, 65535),
[REG_TEMPERATURE] =
SBS_DATA(POWER_SUPPLY_PROP_TEMP, 0x08, 0, 65535),
[REG_VOLTAGE] =
Expand Down Expand Up @@ -366,6 +369,17 @@ static int sbs_status_correct(struct i2c_client *client, int *intval)
return 0;
}

static bool sbs_bat_needs_calibration(struct i2c_client *client)
{
int ret;

ret = sbs_read_word_data(client, sbs_data[REG_BATTERY_MODE].addr);
if (ret < 0)
return false;

return !!(ret & BIT(7));
}

static int sbs_get_battery_presence_and_health(
struct i2c_client *client, enum power_supply_property psp,
union power_supply_propval *val)
Expand All @@ -385,9 +399,14 @@ static int sbs_get_battery_presence_and_health(

if (psp == POWER_SUPPLY_PROP_PRESENT)
val->intval = 1; /* battery present */
else /* POWER_SUPPLY_PROP_HEALTH */
/* SBS spec doesn't have a general health command. */
val->intval = POWER_SUPPLY_HEALTH_UNKNOWN;
else { /* POWER_SUPPLY_PROP_HEALTH */
if (sbs_bat_needs_calibration(client)) {
val->intval = POWER_SUPPLY_HEALTH_CALIBRATION_REQUIRED;
} else {
/* SBS spec doesn't have a general health command. */
val->intval = POWER_SUPPLY_HEALTH_UNKNOWN;
}
}

return 0;
}
Expand Down Expand Up @@ -441,6 +460,8 @@ static int sbs_get_ti_battery_presence_and_health(
val->intval = POWER_SUPPLY_HEALTH_OVERHEAT;
else if (ret == 0x0C)
val->intval = POWER_SUPPLY_HEALTH_DEAD;
else if (sbs_bat_needs_calibration(client))
val->intval = POWER_SUPPLY_HEALTH_CALIBRATION_REQUIRED;
else
val->intval = POWER_SUPPLY_HEALTH_GOOD;
}
Expand Down