KVM: s390: allow injecting all kinds of machine checks
Browse files Browse the repository at this point in the history
Allow to specify CR14, logout area, external damage code
and failed storage address.

Since more then one machine check can be indicated to the guest at
a time we need to combine all indication bits with already pending
requests.

Signed-off-by: Jens Freimann <[email protected]>
Reviewed-by: Cornelia Huck <[email protected]>
Reviewed-by: David Hildenbrand <[email protected]>
Signed-off-by: Christian Borntraeger <[email protected]>
  • Loading branch information
Jens Freimann authored and borntraeger committed Nov 28, 2014
1 parent 383d0b0 commit fc2020c
Showing 1 changed file with 11 additions and 3 deletions.
14 changes: 11 additions & 3 deletions arch/s390/kvm/interrupt.c
Original file line number Diff line number Diff line change
Expand Up @@ -1063,11 +1063,19 @@ static int __inject_mchk(struct kvm_vcpu *vcpu, struct kvm_s390_irq *irq)
mchk->mcic, 2);

/*
* Combine mcic with previously injected machine checks and
* indicate them all together as described in the Principles
* of Operation, Chapter 11, Interruption action
* Because repressible machine checks can be indicated along with
* exigent machine checks (PoP, Chapter 11, Interruption action)
* we need to combine cr14, mcic and external damage code.
* Failing storage address and the logout area should not be or'ed
* together, we just indicate the last occurrence of the corresponding
* machine check
*/
mchk->cr14 |= irq->u.mchk.cr14;
mchk->mcic |= irq->u.mchk.mcic;
mchk->ext_damage_code |= irq->u.mchk.ext_damage_code;
mchk->failing_storage_address = irq->u.mchk.failing_storage_address;
memcpy(&mchk->fixed_logout, &irq->u.mchk.fixed_logout,
sizeof(mchk->fixed_logout));
if (mchk->mcic & MCHK_EX_MASK)
set_bit(IRQ_PEND_MCHK_EX, &li->pending_irqs);
else if (mchk->mcic & MCHK_REP_MASK)
Expand Down