Xic: Refinement for FastHenry interface, volume elements now assume
Browse files Browse the repository at this point in the history
one dimension is film thickness, gives better size value.
  • Loading branch information
wrcad committed Sep 1, 2019
1 parent a77cf5a commit 6103f00
Showing 1 changed file with 8 additions and 7 deletions.
15 changes: 8 additions & 7 deletions xic/src/extract/ext_fh.cc
Original file line number Diff line number Diff line change
Expand Up @@ -591,15 +591,16 @@ fhLayout::setup()
if (var) {
double val = atof(var);
if (val >= FH_MIN_TARG_VOLEL && val <= FH_MAX_TARG_VOLEL) {
double vol = 0.0;
double a = 0.0;
for (Layer3d *l = layers(); l; l = l->next()) {
if (l->is_conductor())
vol += glYlist3d::volume(l->yl3d());
if (l->is_conductor()) {
DspLayerParams *dp = dsp_prm(l->layer_desc());
a += glYlist3d::volume(l->yl3d())/dp->thickness();
}
}
double cvol = vol / val;
max_rect_size = INTERNAL_UNITS(cbrt(cvol));
TPRINT("Volume %g, FhVolElTarget %s, max_rec_size %d\n",
vol, var, max_rect_size);
max_rect_size = INTERNAL_UNITS(sqrt(a/val));
TPRINT("Area %g, FhVolElTarget %s, max_rec_size %d\n",
a, var, max_rect_size);
}
}

Expand Down

0 comments on commit 6103f00