Added AEConversion INV500-90 inverter script. (tasmota#1227)
Browse files Browse the repository at this point in the history
And fixed layout for the ZPA GH305 (SML)
  • Loading branch information
wvdv2002 authored May 8, 2023
1 parent abc51b4 commit 5605db5
Showing 1 changed file with 56 additions and 39 deletions.
95 changes: 56 additions & 39 deletions docs/Smart-Meter-Interface.md
Original file line number Diff line number Diff line change
Expand Up @@ -2786,45 +2786,44 @@ These heating regulators have a [lot of registers](https://raw.githubusercontent
??? summary "View script"
```
>D
>B
->sensor53 r
>M 1
+1,3,s,0,9600,SML
1,77070100010800ff@1000,Total Verbrauch,KWh,Total_in,3
1,77070100020800ff@1000,Total Einspeisung,kWh,Total_in,3
1,=h==================
1,77070100100700ff@1,Actual load,W,Power_curr,0
1,=h==================
1,=m 9+10+11 @1,Currents L1+L2+L3,A,Curr_summ,3
;1,=m 12+13+14/#3 @1,Voltage L1+L2+L3/3,V,Volt_avg,3
1,=h==================
1,77070100240700ff@1,Consumption P1,W,Power_p1,2
1,77070100380700ff@1,Consumption P2,W,Power_p2,2
1,770701004c0700ff@1,Consumption P3,W,Power_p3,2
1,=h ----
1,770701001f0700ff@1,Current L1,A,Curr_p1,3
1,77070100330700ff@1,Current L2,A,Curr_p2,3
1,77070100470700ff@1,Current L3,A,Curr_p3,3
1,=h ----
1,77070100200700ff@1,Voltage L1,V,Volt_p1,3
1,77070100340700ff@1,Voltage L2,V,Volt_p2,3
1,77070100480700ff@1,Voltage L3,V,Volt_p3,3
1,=h==================
1,77070100510701ff@1,Phaseangle L2-L1,deg,phase_angle_L2_L1,0
1,77070100510702ff@1,Phaseangle L3-L1,deg,phase_angle_L3_L1,0
1,77070100510704ff@1,Phaseangle I/U L1,deg,phase_angle_L1,1
1,7707010051070fff@1,Phaseangle I/U L2,deg,phase_angle_L2,1
1,7707010051071aff@1,Phaseangle I/U L3,deg,phase_angle_L3,1
1,770701000e0700ff@1,Frequency,Hz,Freq,1
;1,=h=======UNBEKANNT===========
;1,77070100000009FF@#,unbekannt1,,Power_Use_Sum,3
;1,77070100000000FF@#,unbekannt2,,Power_Use_Sum,3
;1,7707010060320101@#,unbekannt3,,Meter_id,0
;1,77010b0a01445a47@#,unbekannt4,,Meter_id,0
;1,77070100600100ff@#,unbekannt5,,Meter_id,0
1,=h
#

>B
->sensor53 r
>M 1
+1,3,s,0,9600,SML
1,77070100010800ff@1000,Total Verbrauch,KWh,Total_in,3
1,77070100020800ff@1000,Total Einspeisung,kWh,Total_in,3
1,=h==================
1,77070100100700ff@1,Actual load,W,Power_curr,0
1,=h==================
1,=m 9+10+11 @1,Currents L1+L2+L3,A,Curr_summ,3
;1,=m 12+13+14/#3 @1,Voltage L1+L2+L3/3,V,Volt_avg,3
1,=h==================
1,77070100240700ff@1,Consumption P1,W,Power_p1,2
1,77070100380700ff@1,Consumption P2,W,Power_p2,2
1,770701004c0700ff@1,Consumption P3,W,Power_p3,2
1,=h ----
1,770701001f0700ff@1,Current L1,A,Curr_p1,3
1,77070100330700ff@1,Current L2,A,Curr_p2,3
1,77070100470700ff@1,Current L3,A,Curr_p3,3
1,=h ----
1,77070100200700ff@1,Voltage L1,V,Volt_p1,3
1,77070100340700ff@1,Voltage L2,V,Volt_p2,3
1,77070100480700ff@1,Voltage L3,V,Volt_p3,3
1,=h==================
1,77070100510701ff@1,Phaseangle L2-L1,deg,phase_angle_L2_L1,0
1,77070100510702ff@1,Phaseangle L3-L1,deg,phase_angle_L3_L1,0
1,77070100510704ff@1,Phaseangle I/U L1,deg,phase_angle_L1,1
1,7707010051070fff@1,Phaseangle I/U L2,deg,phase_angle_L2,1
1,7707010051071aff@1,Phaseangle I/U L3,deg,phase_angle_L3,1
1,770701000e0700ff@1,Frequency,Hz,Freq,1
;1,=h=======UNBEKANNT===========
;1,77070100000009FF@#,unbekannt1,,Power_Use_Sum,3
;1,77070100000000FF@#,unbekannt2,,Power_Use_Sum,3
;1,7707010060320101@#,unbekannt3,,Meter_id,0
;1,77010b0a01445a47@#,unbekannt4,,Meter_id,0
;1,77070100600100ff@#,unbekannt5,,Meter_id,0
1,=h
#
```

### inepro Metering PRO380-MB (M-Bus)
Expand Down Expand Up @@ -2865,3 +2864,21 @@ To connect to this and read data from the bus a level shifting is needed as the
#

```

### AEConversion solar inverter INVXXX (RAW)
Tested on an AEConversion INV500-90 with RS485 interface.

??? summary "View script"
```
>D
>B
=>sensor53 r
; Monitor Sensor at GPIO25
=>sensor53 l255
>M 1
+1,13,r,0,9600,aec,15,50,2101B203FD4D0D

1,212717UUuux7@1,Leistung,W,power,0
1,212717x4UUuux4@1000,Energie,kWh,energy_sun,3
#
```