Skip to content

dremerb/netbox-topology-views

 
 

Repository files navigation

Netbox Topology Views Plugin

Version Downloads

Create topology views/maps from your devices in NetBox. The connections are based on the cables you created in NetBox. Support to filter on name, site, tag and device role.
Options to export to xml (for draw.io/diagrams.net) or png.

Preview

Topology with light mode Topology with dark mode

Install

NOTE: For docker please see: Docker install

NOTE: Add RUN mkdir -p /opt/netbox/netbox/static/netbox_topology_views/img to the Dockerfile-Plugins file to create the image folder

The plugin is available as a Python package and can be installed with pip.

Run pip install netbox-topology-views in your virtual env.

To ensure NetBox Topology Views plugin is automatically re-installed during future upgrades, create a file named local_requirements.txt (if not already existing) in the NetBox root directory (alongside requirements.txt) and list the netbox-topology-views package:

# echo netbox-topology-views >> local_requirements.txt

Once installed, the plugin needs to be enabled in your configuration.py

# In your configuration.py
PLUGINS = ["netbox_topology_views"]

First run source /opt/netbox/venv/bin/activate to enter the Python virtual environment.

Then run

cd /opt/netbox/netbox
pip3 install netbox-topology-views
python3 manage.py migrate netbox_topology_views
python3 manage.py collectstatic --no-input

Versions

netbox version netbox-topology-views version
>= 3.7.0 >= v3.9.0
>= 3.6.4 >= v3.8.1
>= 3.6.0 >= v3.7.X
>= 3.5.0 >= v3.4.X
>= 3.4.0 >= v3.X.X
>= 3.3.0 >= v3.0.0
>= 3.2.0 >= v1.1.0
>= 3.1.8 >= v1.0.0
>= 2.11.1 >= v0.5.3
>= 2.10.0 >= v0.5.0
< 2.10.0 =< v0.4.10

Update

Run pip install netbox-topology-views --upgrade in your venv.

Run python3 manage.py migrate netbox_topology_views

Run python3 manage.py collectstatic --no-input

Clear you browser cache.

Configure

Individual Options

All individual options can be assigned a default value per user directly in the plugin. The default value can be overridden on the filter page.

Individual Options

The remaining options must be configured in the PLUGINS_CONFIG section of your netbox/configuration.py.

Example:

PLUGINS_CONFIG = {
    'netbox_topology_views': {
        'static_image_directory': 'netbox_topology_views/img',
        'allow_coordinates_saving': True,
        'always_save_coordinates': True
    }
}
Setting Default value Description
static_image_directory netbox_topology_views/img (str or pathlib.Path) Specifies the location that images will be loaded from by default. Must be within STATIC_ROOT
allow_coordinates_saving False (bool) Set to true if you want to enable the ability to save the coordinates.
always_save_coordinates False (bool) Set if you want to enable the option to save coordinates by default. Setting allow_coordinates_saving to true is mandatory.

Custom field: coordinates

There is also support for custom fields.

Note: The custom field "coordinates" is deprecated and will be removed in the future. Please use Coordinate Groups instead.

If you create a custom field "coordinates" for "dcim > device" and "Circuits > circuit" with type "text" and name "coordinates" you will see the same layout every time. It is recommended to set this field to "UI visibility" "Hidden" and let the plugin manage it in the background.

The coordinates are stored as: "X;Y".

Please read the "Configure" chapter to set the allow_coordinates_saving option to True. You might also set the always_save_coordinates option to True.

Convert custom field to Coordinate Groups

Please note that values stored in the custom field "coordinates" are not being converted to Coordinate Groups automatically. A pragmatic way to do this conversion yourself is as follows:

  • Navigate to "Topology" > "Filters".
  • Select "Show Unconnected" and "Show Cables".
  • Leave all other filter settings alone. We want all entries to be displayed!
  • Click "Search" and wait for the results to be displayed
  • Select all nodes. This can be done by holding down the Shift key and dragging a frame around all icons with the left mouse button.
  • Drag the selection a tiny bit to the side. This causes all coordinates for all devices to be stored in the "default" group.

Hint: Don't wait too long after clicking an icon in order to drag. If you hold the mouse button for too long before dragging starts, the selection is reset._

  • Storing the values might take some time, depending on the number of devices. Please be patient and check "Coordinates" in order to make sure that everthing has been stored.
  • It is save to delete the custom field now.

Custom Images

To change image with associated device use the Images page - it allows to map a device role with an image found in the NetBox static directory (defined by the plugin config static_image_directory which defaults to netbox_topology_views/img). You can also upload you own custom images to there - these images will automatically be used for a device (if it does not already have a specified image in the settings) if their name is the device role slug.

Images

Use

Go to the plugins tab in the navbar and click topology or go to $NETBOX_URL/plugins/netbox_topology_views/ to view your topologies

Select your options for the topology view:

Filter Options

Coordinate Group
Select Coordinate Group. These groups allow devices to be displayed in different positions depending on the group, thus providing different representations for the same topology. If nothing is selected, the group "default" is set automatically.
Save Coordinates
Save the coordinates of devices in the topology view.
Show Unconnected
Show devices that have no connections or for which no connection is displayed. This option depends on other parameters like 'Show Cables' and 'Show Logical Connections'.
Show Cables
Show connections between interfaces, front / rear ports, etc., that are connected with one or more cables. These connections are displayed as solid lines in the color of the cable.
Show Logical Connections
Show logical connections between interfaces (referred to as Interface Connections in NetBox) in the topology view. Where the path between interfaces includes multiple cables (e.g., via patch panels), only the end interface connections are shown, not the intermediate front / rear port connections, etc. This is similar to what was referred to as 'end-to-end' connections in previous versions. These connections are displayed as yellow dotted lines.
Show redundant Cable and Logical Connection
Shows a logical connection (in addition to a cable), even if a cable is directly connected. Leaving this option disabled prevents that redundant display. This option only has an effect if 'Show Logical Connections' is activated.
Show Neighbors
Adds neighbors to the filter result set automatically. Link peers will be added if 'Show Cables' is ticked, far-end terminations will be added if 'Show Logical Connections' is ticked.
Show Circuit Terminations
Show connections which end at a circuit termination in the topology view. These connections are displayed as blue dashed lines.
Show Power Feeds
Displays connections between power outlets and power ports. These connections are displayed as solid lines in the color of the cable. This option depends on 'Show Cables'.
Show Wireless Links
Displays wireless connections. These connections are displayed as blue dotted lines.

Coordinates and Coordinate Groups

Netbox Topology Views stores the position of the devices. In order to allow different representations for the topology, Coordinate Groups are supported.

Please read the "Configure" chapter to set the allow_coordinates_saving option to True. You might also set the always_save_coordinates option to True.

Navigate to "Coordinate Groups" in the menu and create as many groups as you like. You can select a group later in the filter pane in order to show icon positions according to this group (see chapter "Use"). You can also omit creating a group if you don't need this feature. Netbox Topology Views automatically creates a group named "default" for you and stores all coordinates in this group, even if you do not select a group in the filter.

By default, the position of the devices are calculated with a physics engine. As soon as a device icon is dragged to another location, its position is saved and excluded from the calculation by the physics engine. All saved coordinates can be viewed and edited under the menu item "Coordinates".

Note: At the time of writing, it is not possible to store the positions of circuit terminations, power panels and power feeds, as these are not devices.

Permissions

To view /plugins/netbox_topology-views/topology you need the following permissions:

  • dcim | device | can view device
  • dcim | site | can view site
  • extras | tag | can view tag
  • dcim | device role | can view device role

To save Coordinates when moving icons:

  • netbox_topology_views | coordinate | change

To view /plugins/netbox_topology-views/images:

  • dcim | site | view
  • dcim | device role | view
  • dcim | device role | add
  • dcim | device role | change

To view /plugins/netbox_topology-views/individualoptions:

  • netbox_topology_views | individual options | change

Set Coordinate Groups according to your needs:

  • netbox_topology_views | coordinate groups | view/add/change/delete

Set Coordinates according to your needs:

  • netbox_topology_views | coordinate | view/add/change/delete

Set Power Feed Coordinates according to your needs:

  • netbox_topology_views | power feed coordinate | view/add/change/delete

Set Power Panel Coordinates according to your needs:

  • netbox_topology_views | power panel coordinate | view/add/change/delete

Set Circuit Coordinates according to your needs:

  • netbox_topology_views | circuit coordinate | view/add/change/delete

About

A netbox plugin that draws topology views

Resources

License

Security policy

Stars

Watchers

Forks

Releases

No releases published

Packages

No packages published

Languages

  • Python 79.0%
  • JavaScript 11.4%
  • HTML 9.3%
  • SCSS 0.3%