forked from torvalds/linux
-
Notifications
You must be signed in to change notification settings - Fork 0
Commit
This commit does not belong to any branch on this repository, and may belong to a fork outside of the repository.
hwmon: (max34440) Add support for MAX34446
Signed-off-by: Guenter Roeck <[email protected]>
- Loading branch information
Showing
3 changed files
with
138 additions
and
7 deletions.
There are no files selected for viewing
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
|
@@ -11,6 +11,11 @@ Supported chips: | |
Prefixes: 'max34441' | ||
Addresses scanned: - | ||
Datasheet: http://datasheets.maxim-ic.com/en/ds/MAX34441.pdf | ||
* Maxim MAX34446 | ||
PMBus Power-Supply Data Logger | ||
Prefixes: 'max34446' | ||
Addresses scanned: - | ||
Datasheet: http://datasheets.maxim-ic.com/en/ds/MAX34446.pdf | ||
|
||
Author: Guenter Roeck <[email protected]> | ||
|
||
|
@@ -19,8 +24,8 @@ Description | |
----------- | ||
|
||
This driver supports hardware montoring for Maxim MAX34440 PMBus 6-Channel | ||
Power-Supply Manager and MAX34441 PMBus 5-Channel Power-Supply Manager | ||
and Intelligent Fan Controller. | ||
Power-Supply Manager, MAX34441 PMBus 5-Channel Power-Supply Manager | ||
and Intelligent Fan Controller, and MAX34446 PMBus Power-Supply Data Logger. | ||
|
||
The driver is a client driver to the core PMBus driver. Please see | ||
Documentation/hwmon/pmbus for details on PMBus client drivers. | ||
|
@@ -33,6 +38,13 @@ This driver does not auto-detect devices. You will have to instantiate the | |
devices explicitly. Please see Documentation/i2c/instantiating-devices for | ||
details. | ||
|
||
For MAX34446, the value of the currX_crit attribute determines if current or | ||
voltage measurement is enabled for a given channel. Voltage measurement is | ||
enabled if currX_crit is set to 0; current measurement is enabled if the | ||
attribute is set to a positive value. Power measurement is only enabled if | ||
channel 1 (3) is configured for voltage measurement, and channel 2 (4) is | ||
configured for current measurement. | ||
|
||
|
||
Platform data support | ||
--------------------- | ||
|
@@ -60,16 +72,27 @@ in[1-6]_lowest Historical minimum voltage. | |
in[1-6]_highest Historical maximum voltage. | ||
in[1-6]_reset_history Write any value to reset history. | ||
|
||
MAX34446 only supports in[1-4]. | ||
|
||
curr[1-6]_label "iout[1-6]". | ||
curr[1-6]_input Measured current. From READ_IOUT register. | ||
curr[1-6]_max Maximum current. From IOUT_OC_WARN_LIMIT register. | ||
curr[1-6]_crit Critical maximum current. From IOUT_OC_FAULT_LIMIT register. | ||
curr[1-6]_max_alarm Current high alarm. From IOUT_OC_WARNING status. | ||
curr[1-6]_crit_alarm Current critical high alarm. From IOUT_OC_FAULT status. | ||
curr[1-4]_average Historical average current (MAX34446 only). | ||
curr[1-6]_highest Historical maximum current. | ||
curr[1-6]_reset_history Write any value to reset history. | ||
|
||
in6 and curr6 attributes only exist for MAX34440. | ||
MAX34446 only supports curr[1-4]. | ||
|
||
power[1,3]_label "pout[1,3]" | ||
power[1,3]_input Measured power. | ||
power[1,3]_average Historical average power. | ||
power[1,3]_highest Historical maximum power. | ||
|
||
Power attributes only exist for MAX34446. | ||
|
||
temp[1-8]_input Measured temperatures. From READ_TEMPERATURE_1 register. | ||
temp1 is the chip's internal temperature. temp2..temp5 | ||
|
@@ -80,7 +103,9 @@ temp[1-8]_max Maximum temperature. From OT_WARN_LIMIT register. | |
temp[1-8]_crit Critical high temperature. From OT_FAULT_LIMIT register. | ||
temp[1-8]_max_alarm Temperature high alarm. | ||
temp[1-8]_crit_alarm Temperature critical high alarm. | ||
temp[1-8]_average Historical average temperature (MAX34446 only). | ||
temp[1-8]_highest Historical maximum temperature. | ||
temp[1-8]_reset_history Write any value to reset history. | ||
|
||
temp7 and temp8 attributes only exist for MAX34440. | ||
MAX34446 only supports temp[1-3]. |
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters