Troubleshoot application upgrades

This article covers some of the common issues around upgrading an Azure Service Fabric application and how to resolve them.

Troubleshoot a failed application upgrade

When an upgrade fails, the output of the Get-ServiceFabricApplicationUpgrade command will contain some additional information for debugging the failure. This information can be used to:

  1. Identify the failure type.
  2. Identify the failure reason.
  3. Isolate the failing component(s) for further investigation.

This information will be available as soon as Service Fabric detects the failure regardless of whether the FailureAction is to roll back or suspend the upgrade.

Identify the failure type

In the output of Get-ServiceFabricApplicationUpgrade, FailureTimestampUtc identifies the timestamp (in UTC) at which an upgrade failure was detected by Service Fabric and FailureAction was triggered. FailureReason identifies one of three potential high-level causes of the failure:

  1. UpgradeDomainTimeout - Indicates that a particular upgrade domain took too long to complete and UpgradeDomainTimeout expired.
  2. OverallUpgradeTimeout - Indicates that the overall upgrade took too long to complete and UpgradeTimeout expired.
  3. HealthCheck - Indicates that after upgrading an udpate domain, the application remained unhealthy according to the specified health policies and HealthCheckRetryTimeout expired.

These entries will only show up in the output when the upgrade fails and starts rolling back. Further information will be displayed depending on the type of the failure.

Investigate upgrade timeouts

Upgrade timeout failures are most commonly caused by service availability issues. The output below is typical of upgrades where service replicas or instances fail to start in the new code version. The UpgradeDomainProgressAtFailure field captures a snapshot of any pending upgrade work at the time of failure.

PS D:\temp> Get-ServiceFabricApplicationUpgrade fabric:/DemoApp

ApplicationName                : fabric:/DemoApp
ApplicationTypeName            : DemoAppType
TargetApplicationTypeVersion   : v2
ApplicationParameters          : {}
StartTimestampUtc              : 4/14/2015 9:26:38 PM
FailureTimestampUtc            : 4/14/2015 9:27:05 PM
FailureReason                  : UpgradeDomainTimeout
UpgradeDomainProgressAtFailure : MYUD1

                                 NodeName            : Node4
                                 UpgradePhase        : PostUpgradeSafetyCheck
                                 PendingSafetyChecks :
                                     WaitForPrimaryPlacement - PartitionId: 744c8d9f-1d26-417e-a60e-cd48f5c098f0

                                 NodeName            : Node1
                                 UpgradePhase        : PostUpgradeSafetyCheck
                                 PendingSafetyChecks :
                                     WaitForPrimaryPlacement - PartitionId: 4b43f4d8-b26b-424e-9307-7a7a62e79750
UpgradeState                   : RollingBackCompleted
UpgradeDuration                : 00:00:46
CurrentUpgradeDomainDuration   : 00:00:00
NextUpgradeDomain              :
UpgradeDomainsStatus           : { "MYUD1" = "Completed";
                                 "MYUD2" = "Completed";
                                 "MYUD3" = "Completed" }
UpgradeKind                    : Rolling
RollingUpgradeMode             : UnmonitoredAuto
ForceRestart                   : False
UpgradeReplicaSetCheckTimeout  : 00:00:00

In this example, we can see that the upgrade failed at upgrade domain MYUD1 and that two partitions (744c8d9f-1d26-417e-a60e-cd48f5c098f0 and 4b43f4d8-b26b-424e-9307-7a7a62e79750) were stuck, unable to place primary replicas (WaitForPrimaryPlacement) on target nodes Node1 and Node4.

The Get-ServiceFabricNode command can be used to verify that these two nodes are in upgrade domain MYUD1. The UpgradePhase says PostUpgradeSafetyCheck, which means that these safety checks are occurring after all nodes in the upgrade domain have finished upgrading. All this information points to a potential issue with the new version of the application code. The most common issues are service errors in the open or promotion to primary code paths.

An UpgradePhase of PreUpgradeSafetyCheck means there were issues preparing the upgrade domain before it was actually performed. The most common issues in this case are service errors in the close or demotion from primary code paths.

The current UpgradeState is RollingBackCompleted, so the original upgrade must have been performed with a rollback FailureAction, which automatically rolled back the upgrade upon failure. If the original upgrade had been performed with a manual FailureAction, then the upgrade would instead be in a suspended state to allow live debugging of the application.

Investigate health check failures

Health check failures can be triggered by a variety of additional issues that can happen after all nodes in an upgrade domain finish upgrading and passing all safety checks. The output below is typical of an upgrade failure due to failed health checks. The UnhealthyEvaluations field captures a snapshot of all failing health checks at the time of the upgrade failure according the user-specified health policy.

PS D:\temp> Get-ServiceFabricApplicationUpgrade fabric:/DemoApp

ApplicationName                         : fabric:/DemoApp
ApplicationTypeName                     : DemoAppType
TargetApplicationTypeVersion            : v4
ApplicationParameters                   : {}
StartTimestampUtc                       : 4/24/2015 2:42:31 AM
UpgradeState                            : RollingForwardPending
UpgradeDuration                         : 00:00:27
CurrentUpgradeDomainDuration            : 00:00:27
NextUpgradeDomain                       : MYUD2
UpgradeDomainsStatus                    : { "MYUD1" = "Completed";
                                          "MYUD2" = "Pending";
                                          "MYUD3" = "Pending" }
UnhealthyEvaluations                    :
                                          Unhealthy services: 50% (2/4), ServiceType='PersistedServiceType', MaxPercentUnhealthyServices=0%.

                                          Unhealthy service: ServiceName='fabric:/DemoApp/Svc3', AggregatedHealthState='Error'.

                                              Unhealthy partitions: 100% (1/1), MaxPercentUnhealthyPartitionsPerService=0%.

                                              Unhealthy partition: PartitionId='3a9911f6-a2e5-452d-89a8-09271e7e49a8', AggregatedHealthState='Error'.

                                                  Error event: SourceId='Replica', Property='InjectedFault'.

                                          Unhealthy service: ServiceName='fabric:/DemoApp/Svc2', AggregatedHealthState='Error'.

                                              Unhealthy partitions: 100% (1/1), MaxPercentUnhealthyPartitionsPerService=0%.

                                              Unhealthy partition: PartitionId='744c8d9f-1d26-417e-a60e-cd48f5c098f0', AggregatedHealthState='Error'.

                                                  Error event: SourceId='Replica', Property='InjectedFault'.

UpgradeKind                             : Rolling
RollingUpgradeMode                      : Monitored
FailureAction                           : Manual
ForceRestart                            : False
UpgradeReplicaSetCheckTimeout           : 49710.06:28:15
HealthCheckWaitDuration                 : 00:00:00
HealthCheckStableDuration               : 00:00:10
HealthCheckRetryTimeout                 : 00:00:10
UpgradeDomainTimeout                    : 10675199.02:48:05.4775807
UpgradeTimeout                          : 10675199.02:48:05.4775807
ConsiderWarningAsError                  :
MaxPercentUnhealthyPartitionsPerService :
MaxPercentUnhealthyReplicasPerPartition :
MaxPercentUnhealthyServices             :
MaxPercentUnhealthyDeployedApplications :
ServiceTypeHealthPolicyMap              :

Investigating health check failures first requires an understanding of the Service Fabric health model. But even without such an in-depth understanding, we can see that two services are unhealthy: fabric:/DemoApp/Svc3 and fabric:/DemoApp/Svc2, along with the error health reports ("InjectedFault" in this case). In this example, two out of four services are unhealthy, which is below the default target of 0% unhealthy (MaxPercentUnhealthyServices).

The upgrade was suspended upon failing by specifying a FailureAction of manual when starting the upgrade, so we can investigate the live system in the failed state, if desired, before taking any further actions.

Recover from a suspended upgrade

With a rollback FailureAction, there is no recovery needed since the upgrade will automatically roll back upon failing. With a manual FailureAction, there are several recovery options:

  1. Manually trigger a rollback
  2. Proceed through the remainder of the upgrade manually
  3. Resume the monitored upgrade

The Start-ServiceFabricApplicationRollback command can be used at any time to start rolling back the application. Once the command returns successfully, the rollback request has been registered in the system and will start shortly.

The Resume-ServiceFabricApplicationUpgrade command can be used to proceed through the remainder of the upgrade manually, one upgrade domain at a time. In this mode, only safety checks will be performed by the system. No more health checks will be performed. This command can only be used when the UpgradeState shows RollingForwardPending, which means that the current upgrade domain has finished upgrading but the next upgrade domain has not started yet (pending).

The Update-ServiceFabricApplicationUpgrade command can be used to resume the monitored upgrade with both safety and health checks being performed.

PS D:\temp> Update-ServiceFabricApplicationUpgrade fabric:/DemoApp -UpgradeMode Monitored

UpgradeMode                             : Monitored
ForceRestart                            :
UpgradeReplicaSetCheckTimeout           :
FailureAction                           :
HealthCheckWaitDuration                 :
HealthCheckStableDuration               :
HealthCheckRetryTimeout                 :
UpgradeTimeout                          :
UpgradeDomainTimeout                    :
ConsiderWarningAsError                  :
MaxPercentUnhealthyPartitionsPerService :
MaxPercentUnhealthyReplicasPerPartition :
MaxPercentUnhealthyServices             :
MaxPercentUnhealthyDeployedApplications :
ServiceTypeHealthPolicyMap              :

PS D:\temp>

The upgrade will continue from the upgrade domain where it was last suspended and use the same upgrade parameters and health policies as before. If needed, any of the upgrade parameters and health policies shown in the output above can be changed in the same command when the upgrade resumes. In this example, the upgrade was resumed in Monitored mode, leaving all other parameters unchanged, and using the same parameters and health policies as before.

Further troubleshooting

Service Fabric is not following the specified health policies

Possible Cause 1:

Service Fabric translates all percentages into actual numbers of entities (e.g. replicas, partitions, and services) for health evaluation and always rounds up to the nearest number of whole entities. For example, if the maximum MaxPercentUnhealthyReplicasPerPartition is 21% and there are five replicas, then Service Fabric will allow up to two replicas (i.e., Math.Ceiling (5\*0.21)) to be unhealthy when evaluating partition health. Health policies should be set accordingly to account for this.

Possible Cause 2:

Health policies are specified in terms of percentages of total services and not specific service instances. For example, before an upgrade, assume that an application has four service instances A, B, C, and D, where service D is unhealthy but with no significant impact on the application. We want to ignore the known unhealthy service D during upgrade and set the parameter MaxPercentUnhealthyServices to be 25%, assuming only A, B, and C need to be healthy.

However, during the upgrade, D may become healthy while C becomes unhealthy. The upgrade would still finish successfully in this case since only 25% of the services are unhealthy, but it might result in unanticipated errors due to C being unexpectedly unhealthy instead of D. In this situation, D should be modeled as a different service type from A, B, and C. Since health policies can be specified on a per-service type basis, this would allow different unhealthy percentage thresholds to be applied to different services based on their roles in the application.

I did not specify a health policy for application upgrade, but the upgrade still fails for some time-outs that I never specified

When health policies aren't provided to the upgrade request, they are taken from the ApplicationManifest.xml of the current application version. For example, if you're upgrading Application X from v1 to v2, application health policies specified for Application X in v1 are used. If a different health policy should be used for the upgrade, then the policy needs to be specified as part of the application upgrade API call. Note that the policies specified as part of the API call only apply for the duration of the upgrade. Once the upgrade is complete, the policies specified in the ApplicationManifest.xml are used.

Incorrect time-outs are specified

Users may have wondered about what happens if the time-outs are set inconsistently, for example, if you have an UpgradeTimeout that's less than the UpgradeDomainTimeout. The answer is that an error is returned. Other cases where this may happen is if UpgradeDomainTimeout is less than the sum of HealthCheckWaitDuration and HealthCheckRetryTimeout, or if UpgradeDomainTimeout is less than the sum of HealthCheckWaitDuration and HealthCheckStableDuration.

My upgrades are taking too long

The time it takes for an upgrade to finish is dependent on the various health checks and time-outs specified, which in turn are dependent on the time it takes for your application to upgrade (including copying the package, deploying, and stabilizing). Being too aggressive with time-outs might mean more failed upgrades, so we recommend starting conservatively with longer time-outs.

Here's a quick refresher on how the time-outs interact with the upgrade times:

Upgrades for an upgrade domain cannot complete faster than HealthCheckWaitDuration + HealthCheckStableDuration.

Upgrade failure cannot occur faster than HealthCheckWaitDuration + HealthCheckRetryTimeout.

The upgrade time for an upgrade domain is limited by UpgradeDomainTimeout. If HealthCheckRetryTimeout and HealthCheckStableDuration are both non-zero and the health of the application keeps switching back and forth, then the upgrade will eventually time out on UpgradeDomainTimeout. UpgradeDomainTimeout starts counting down once the upgrade for the current upgrade domain begins.

Next steps

Uprading your Application Using Visual Studio walks you through an application upgrade using Visual Studio.

Uprading your Application Using Powershell walks you through an application upgrade using PowerShell.

Control how your application upgrades by using Upgrade Parameters.

Make your application upgrades compatible by learning how to use Data Serialization.

Learn how to use advanced functionality while upgrading your application by referring to Advanced Topics.

Fix common problems in application upgrades by referring to the steps in Troubleshooting Application Upgrades .