firewire: ohci: work around VIA and NEC PHY packet reception bug
Browse files Browse the repository at this point in the history
VIA VT6306, VIA VT6308, and NEC OrangeLink controllers do not write
packet event codes for received PHY packets (or perhaps write
evt_no_status, hard to tell).  Work around it by overwriting the
packet's ACK by ack_complete, so that upper layers that listen to PHY
packet reception get to see these packets.

(Also tested:  TI TSB82AA2, TI TSB43AB22/A, TI XIO2213A, Agere FW643,
JMicron JMB381 --- these do not exhibit this bug.)

Clemens proposed a quirks flag for that, IOW whitelist known misbehaving
controllers for this workaround.  Though to me it seems harmless enough
to enable for all controllers.

The log_ar_at_event() debug log will continue to show the original
status from the DMA unit.

Reported-by: Clemens Ladisch <[email protected]> (VT6308)
Signed-off-by: Stefan Richter <[email protected]>
  • Loading branch information
Stefan Richter committed Aug 29, 2010
1 parent 2222bcb commit a4dc090
Showing 1 changed file with 9 additions and 1 deletion.
10 changes: 9 additions & 1 deletion drivers/firewire/ohci.c
Original file line number Diff line number Diff line change
Expand Up @@ -694,7 +694,15 @@ static __le32 *handle_ar_packet(struct ar_context *ctx, __le32 *buffer)
log_ar_at_event('R', p.speed, p.header, evt);

/*
* The OHCI bus reset handler synthesizes a phy packet with
* Several controllers, notably from NEC and VIA, forget to
* write ack_complete status at PHY packet reception.
*/
if (evt == OHCI1394_evt_no_status &&
(p.header[0] & 0xff) == (OHCI1394_phy_tcode << 4))
p.ack = ACK_COMPLETE;

/*
* The OHCI bus reset handler synthesizes a PHY packet with
* the new generation number when a bus reset happens (see
* section 8.4.2.3). This helps us determine when a request
* was received and make sure we send the response in the same
Expand Down