Skip to content

Commit

Permalink
* Added an option to initialize a newly build atmos computer to eithe…
Browse files Browse the repository at this point in the history
…r monitoring distribution loop or the tanks.

Atmos computer are now reconstructible and usable.
* Make the atmos computers dialog auto-refresh so you can keep track of the data evolution (pressure rising, gaz mixture changing, etc)
* Formatted the dialog output for better readability
* Make the alert computer refresh when clearing an alert and updated the action text to tell what (area) alert was cleared (tgstation#3210).
  • Loading branch information
Menshin committed Apr 13, 2014
1 parent aeda005 commit c3ff3fd
Show file tree
Hide file tree
Showing 2 changed files with 59 additions and 26 deletions.
75 changes: 54 additions & 21 deletions code/game/machinery/atmo_control.dm
Original file line number Diff line number Diff line change
@@ -1,3 +1,7 @@
/////////////////////////////////////////////////////////////
// AIR SENSOR (found in gaz tanks)
/////////////////////////////////////////////////////////////

obj/machinery/air_sensor
icon = 'icons/obj/stationobjs.dmi'
icon_state = "gsensor1"
Expand Down Expand Up @@ -73,6 +77,10 @@ obj/machinery/air_sensor/New()
if(radio_controller)
set_frequency(frequency)

/////////////////////////////////////////////////////////////
// GENERAL AIR CONTROL (a.k.a atmos computer)
/////////////////////////////////////////////////////////////

obj/machinery/computer/general_air_control/Destroy()
radio_controller.remove_object(src, frequency)
..()
Expand All @@ -99,21 +107,18 @@ obj/machinery/computer/general_air_control/New()
obj/machinery/computer/general_air_control/attack_hand(mob/user)
if(..(user))
return
//user << browse(return_text(),"window=computer")
user.set_machine(src)
//onclose(user, "computer")
interact(user) //UpdateDialog() is calling /interact each tick, not attack_hand()


var/datum/browser/popup = new(user, "computer", name, 465, 390)
obj/machinery/computer/general_air_control/interact(mob/user)
var/datum/browser/popup = new(user, "computer", name, 480, 490) //update the content every tick
popup.set_content(return_text())
popup.set_title_image(user.browse_rsc_icon(src.icon, src.icon_state))
popup.open()

obj/machinery/computer/general_air_control/interact(mob/user)
attack_hand(user)

obj/machinery/computer/general_air_control/process()
..()
src.updateDialog()
if(..()) //if the computer is not broken or unpowered
src.updateDialog()

obj/machinery/computer/general_air_control/receive_signal(datum/signal/signal)
if(!signal || signal.encryption) return
Expand All @@ -125,7 +130,10 @@ obj/machinery/computer/general_air_control/receive_signal(datum/signal/signal)

obj/machinery/computer/general_air_control/proc/return_text()
var/sensor_data
var/count = 0
if(sensors.len)
sensor_data += "<TABLE cellpadding='3'><TR>" //begin the 3x2 table formatting

for(var/id_tag in sensors)
var/long_name = sensors[id_tag]
var/list/data = sensor_information[id_tag]
Expand All @@ -152,10 +160,16 @@ obj/machinery/computer/general_air_control/proc/return_text()
else
sensor_part = "<FONT class='bad'>[long_name] can not be found!</FONT><BR>"

sensor_data += sensor_part

sensor_data += "<TD valign='top'>[sensor_part]</TD>"//add the data to the current table cell
count++;
if(count == 2) //if we've put two readings on a line...
sensor_data +="</TR><TR>" //... start a new one
count = 0
sensor_data += "</TR></TABLE>" //end the table formatting
else
sensor_data = "No sensors connected."
sensor_data = "No sensors connected.<BR><BR>" // there's nothing in the sensors list (new computer), so choose between the two atmos computers
sensor_data += "<A href='?src=\ref[src];dist_loop=1'>Initialize as Distribution and Waste Monitor</A><BR>"
sensor_data += "<A href='?src=\ref[src];tank_mon=1'>Initialize as Tank Monitor</A><BR>"

var/output = {"
<h1>Sensor Data</h1>[sensor_data]"}
Expand All @@ -174,6 +188,25 @@ obj/machinery/computer/general_air_control/proc/set_frequency(new_frequency)
obj/machinery/computer/general_air_control/initialize()
set_frequency(frequency)

obj/machinery/computer/general_air_control/Topic(href, href_list)
if(..())
return

if(href_list["dist_loop"])
name = "Distribution and Waste Monitor"
set_frequency(1443)
sensors = list("mair_in_meter" = "Mixed Air In", "air_sensor" = "Mixed Air Supply Tank", "mair_out_meter" = "Mixed Air Out", "dloop_atm_meter" = "Distribution Loop", "wloop_atm_meter" = "Waste Loop")

if(href_list["tank_mon"])
name = "Tank Monitor"
set_frequency(1441)
sensors = list("n2_sensor" = "Nitrogen", "o2_sensor" = "Oxygen", "co2_sensor" = "Carbon Dioxide", "tox_sensor" = "Toxins", "n2o_sensor" = "Nitrous Oxide", "waste_sensor" = "Gas Mix Tank")


/////////////////////////////////////////////////////////////
// LARGE TANK CONTROL
/////////////////////////////////////////////////////////////

obj/machinery/computer/general_air_control/large_tank_control
icon = 'icons/obj/computer.dmi'
icon_state = "tank"
Expand Down Expand Up @@ -230,9 +263,10 @@ obj/machinery/computer/general_air_control/large_tank_control/proc/reconnect(mob

obj/machinery/computer/general_air_control/large_tank_control/return_text()
var/output = "<A href='?src=\ref[src];reconnect=1'>Reconnect</A><BR>"
output += ..()
//if(signal.data)
// input_info = signal.data // Attempting to fix intake control
if(sensors.len) //if recieving signals from nearby sensors...
output += ..() //... get the data.
else
output += "No sensors connected."

output += "<h1>Tank Control System</h1>"
if(input_info)
Expand All @@ -253,12 +287,11 @@ Rate: [volume_rate] L/sec<BR>"}
output += {"<B>Output</B>: [power?("Open"):("On Hold")] <A href='?src=\ref[src];out_refresh_status=1'>Refresh</A><BR>
<B>Max Output Pressure:</B> [output_pressure] kPa<BR>"}
output += "<B>Command:</B> <A href='?src=\ref[src];out_toggle_power=1'>Toggle Power</A> <A href='?src=\ref[src];out_set_pressure=1'>Set Pressure</A><BR>"
output += "<B>Max Output Pressure Set:</B> <A href='?src=\ref[src];adj_pressure=-1000'>-</A> <A href='?src=\ref[src];adj_pressure=-100'>-</A> <A href='?src=\ref[src];adj_pressure=-10'>-</A> <A href='?src=\ref[src];adj_pressure=-1'>-</A> [pressure_setting] kPa <A href='?src=\ref[src];adj_pressure=1'>+</A> <A href='?src=\ref[src];adj_pressure=10'>+</A> <A href='?src=\ref[src];adj_pressure=100'>+</A> <A href='?src=\ref[src];adj_pressure=1000'>+</A><BR>"

else
output += "<FONT color='red'>ERROR: Can not find output port</FONT><BR>"

output += "<B>Max Output Pressure Set:</B> <A href='?src=\ref[src];adj_pressure=-1000'>-</A> <A href='?src=\ref[src];adj_pressure=-100'>-</A> <A href='?src=\ref[src];adj_pressure=-10'>-</A> <A href='?src=\ref[src];adj_pressure=-1'>-</A> [pressure_setting] kPa <A href='?src=\ref[src];adj_pressure=1'>+</A> <A href='?src=\ref[src];adj_pressure=10'>+</A> <A href='?src=\ref[src];adj_pressure=100'>+</A> <A href='?src=\ref[src];adj_pressure=1000'>+</A><BR>"

return output

obj/machinery/computer/general_air_control/large_tank_control/receive_signal(datum/signal/signal)
Expand All @@ -280,8 +313,6 @@ obj/machinery/computer/general_air_control/large_tank_control/Topic(href, href_l
if(href_list["adj_pressure"])
var/change = text2num(href_list["adj_pressure"])
pressure_setting = Clamp(pressure_setting + change, 0, 50*ONE_ATMOSPHERE)
spawn(1)
src.updateDialog()
return

if(!radio_connection)
Expand Down Expand Up @@ -314,8 +345,10 @@ obj/machinery/computer/general_air_control/large_tank_control/Topic(href, href_l
signal.data["sigtype"]="command"
radio_connection.post_signal(src, signal, filter = RADIO_ATMOSIA)

spawn(5)
src.updateDialog()

/////////////////////////////////////////////////////////////
// FUEL INJECTION
/////////////////////////////////////////////////////////////

obj/machinery/computer/general_air_control/fuel_injection
icon = 'icons/obj/computer.dmi'
Expand Down
10 changes: 5 additions & 5 deletions code/game/machinery/computer/atmos_alert.dm
Original file line number Diff line number Diff line change
Expand Up @@ -47,9 +47,9 @@
/obj/machinery/computer/atmos_alert/attack_hand(mob/user)
if(..(user))
return
user.set_machine(src)
//user << browse(return_text(),"window=computer")
//onclose(user, "computer")
interact(user) //UpdateDialog() is calling /interact each tick, not attack_hand()

/obj/machinery/computer/atmos_alert/interact(mob/user)
var/datum/browser/popup = new(user, "computer", name)
popup.set_content(return_text())
popup.set_title_image(user.browse_rsc_icon(src.icon, src.icon_state))
Expand Down Expand Up @@ -112,14 +112,14 @@
var/removing_zone = href_list["priority_clear"]
for(var/zone in priority_alarms)
if(ckey(zone) == removing_zone)
usr << "\green Priority Alert for area [] cleared."
usr << "\green Priority Alert for [format_text(zone)] cleared."
priority_alarms -= zone

if(href_list["minor_clear"])
var/removing_zone = href_list["minor_clear"]
for(var/zone in minor_alarms)
if(ckey(zone) == removing_zone)
usr << "\green Minor Alert for area [] cleared."
usr << "\green Minor Alert for [format_text(zone)] cleared."
minor_alarms -= zone
update_icon()
return

0 comments on commit c3ff3fd