rtc: armada38x: reset after rtc power loss
When the RTC block looses power it needs a reset sequence to make it usable again. Otherwise, writes to the time register have no effect. This reset sequence combines information from the mvebu_rtc driver in the Marvell provided U-Boot, and the SolidRun provided U-Boot repo. Tested on the Armada 388 based SolidRun Clearfog Base. Signed-off-by: Baruch Siach <[email protected]> Acked-by: Gregory CLEMENT <[email protected]> Signed-off-by: Alexandre Belloni <[email protected]>