phy: ti-pipe3: use ti_pipe3_power_off to power off the PHY during probe
Browse files Browse the repository at this point in the history
No functional change. Previously omap_control_phy_power() was used to power
off the PHY during probe. But once PIPE3 driver is adapted to use syscon,
omap_control_phy_power() cannot be used. Hence used ti_pipe3_power_off
to power off the PHY.

Signed-off-by: Kishon Vijay Abraham I <[email protected]>
Acked-by: Roger Quadros <[email protected]>
  • Loading branch information
kishon committed Dec 21, 2015
1 parent 1fe5212 commit cc34ace
Showing 1 changed file with 3 additions and 2 deletions.
5 changes: 3 additions & 2 deletions drivers/phy/phy-ti-pipe3.c
Original file line number Diff line number Diff line change
Expand Up @@ -475,8 +475,6 @@ static int ti_pipe3_probe(struct platform_device *pdev)
if (ret)
return ret;

omap_control_phy_power(phy->control_dev, 0);

platform_set_drvdata(pdev, phy);
pm_runtime_enable(dev);

Expand All @@ -495,6 +493,9 @@ static int ti_pipe3_probe(struct platform_device *pdev)
return PTR_ERR(generic_phy);

phy_set_drvdata(generic_phy, phy);

ti_pipe3_power_off(generic_phy);

phy_provider = devm_of_phy_provider_register(dev, of_phy_simple_xlate);
if (IS_ERR(phy_provider))
return PTR_ERR(phy_provider);
Expand Down

0 comments on commit cc34ace