Testcase in which the solution off a runopp can not be recreated with a
Browse files Browse the repository at this point in the history
runpp, referring to the load parameter const_i_percent.

Without const_i_percent the results can be reacreated with a runpp.
  • Loading branch information
jwiemer112 committed Mar 4, 2020
1 parent 7599aea commit 5df0054
Showing 1 changed file with 83 additions and 0 deletions.
83 changes: 83 additions & 0 deletions pandapower/test/opf/test_opf_pf_comparison.py
Original file line number Diff line number Diff line change
@@ -0,0 +1,83 @@
# -*- coding: utf-8 -*-
"""
Created on Tue Mar 3 10:48:47 2020
@author: jwiemer
"""

import pytest
import numpy as np
import pandapower as pp

try:
import pplog as logging
except ImportError:
import logging

logger = logging.getLogger(__name__)


def SimpleGrid():
# Create a Simple Example Network with 50 Hz
net = pp.create_empty_network(f_hz=50.0)

b1 = pp.create_bus(net, vn_kv=110, name='b1_hv', type='n')
b2 = pp.create_bus(net, vn_kv=110, name='b10', type='n')

pp.create_line(net, b1, b2, length_km=1, std_type='243-AL1/39-ST1A 110.0', name='l3')

# Chose the load to match nominal current
p_ac = 110 * 0.645 * np.sqrt(3)
pp.create_load(net, b2, sn_mva=p_ac, q_mvar=5, p_mw=p_ac, name="load_b8", const_i_percent=0)

pp.create_sgen(net, b2, sn_mva=p_ac*1.05, q_mvar=50, p_mw=p_ac, name="sgen_b8")

pp.create_ext_grid(net, 0, vm_pu=1, va_degree=0, s_sc_max_mva=20 * 110 * np.sqrt(3), rx_max=0.1)
return net


def test_OPF_PF_Comparison():
net = SimpleGrid()

# OPF usage
net.line['max_loading_percent'] = 100

# Load
net.load["controllable"] = False

# Sgen
net.sgen["controllable"] = True

net.sgen['max_p_mw'] = net.sgen.p_mw
net.sgen['min_p_mw'] = 0

net.sgen['max_q_mvar'] = 50
net.sgen['min_q_mvar'] = net.sgen.q_mvar

# Bus
net.bus['max_vm_pu'] = 1.05
net.bus['min_vm_pu'] = 0.95

# Maximizing Generation
for i in net.sgen.index:
pp.create_poly_cost(net, i, 'sgen', cp1_eur_per_mw=-1)

pp.runopp(net)
loading_result_opf = net.res_line.loading_percent

# Transfer OPF Solution
net.sgen.p_mw = net.res_sgen.p_mw
net.sgen.q_mvar = net.res_sgen.q_mvar

net.load.p_mw = net.res_load.p_mw
net.load.q_mvar = net.res_load.q_mvar

# Calculate Powerflow in order to compare the results
pp.runpp(net)
loading_result_pf = net.res_line.loading_percent

assert np.isclose(loading_result_pf, loading_result_opf)


if __name__ == '__main__':
pytest.main(['-xs', __file__])