KVM: nVMX: Use vmx_need_pf_intercept() when deciding if L0 wants a #PF
Browse files Browse the repository at this point in the history
commit 18712c1 upstream.

Use vmx_need_pf_intercept() when determining if L0 wants to handle a #PF
in L2 or if the VM-Exit should be forwarded to L1.  The current logic fails
to account for the case where #PF is intercepted to handle
guest.MAXPHYADDR < host.MAXPHYADDR and ends up reflecting all #PFs into
L1.  At best, L1 will complain and inject the #PF back into L2.  At
worst, L1 will eat the unexpected fault and cause L2 to hang on infinite
page faults.

Note, while the bug was technically introduced by the commit that added
support for the MAXPHYADDR madness, the shame is all on commit
a0c1343 ("KVM: VMX: introduce vmx_need_pf_intercept").

Fixes: 1dbf5d6 ("KVM: VMX: Add guest physical address check in EPT violation and misconfig")
Cc: [email protected]
Cc: Peter Shier <[email protected]>
Cc: Oliver Upton <[email protected]>
Cc: Jim Mattson <[email protected]>
Signed-off-by: Sean Christopherson <[email protected]>
Message-Id: <[email protected]>
Signed-off-by: Paolo Bonzini <[email protected]>
Signed-off-by: Greg Kroah-Hartman <[email protected]>
  • Loading branch information
sean-jc authored and gregkh committed Aug 18, 2021
1 parent 0ab67e3 commit 433f0b3
Showing 1 changed file with 2 additions and 1 deletion.
3 changes: 2 additions & 1 deletion arch/x86/kvm/vmx/nested.c
Original file line number Diff line number Diff line change
Expand Up @@ -5779,7 +5779,8 @@ static bool nested_vmx_l0_wants_exit(struct kvm_vcpu *vcpu,
if (is_nmi(intr_info))
return true;
else if (is_page_fault(intr_info))
return vcpu->arch.apf.host_apf_flags || !enable_ept;
return vcpu->arch.apf.host_apf_flags ||
vmx_need_pf_intercept(vcpu);
else if (is_debug(intr_info) &&
vcpu->guest_debug &
(KVM_GUESTDBG_SINGLESTEP | KVM_GUESTDBG_USE_HW_BP))
Expand Down

0 comments on commit 433f0b3

Please sign in to comment.