Skip to content

Commit

Permalink
ts2phc: Add serial baudrate option
Browse files Browse the repository at this point in the history
Add serial baudrate configuration option. Default to 9600 bps.

Signed-off-by: Lars Munch <[email protected]>
  • Loading branch information
lmunch authored and richardcochran committed Jul 19, 2021
1 parent bf4eee2 commit 47c9a2d
Show file tree
Hide file tree
Showing 3 changed files with 18 additions and 16 deletions.
1 change: 1 addition & 0 deletions config.c
Original file line number Diff line number Diff line change
Expand Up @@ -316,6 +316,7 @@ struct config_item config_tab[] = {
PORT_ITEM_INT("ts2phc.extts_correction", 0, INT_MIN, INT_MAX),
PORT_ITEM_ENU("ts2phc.extts_polarity", PTP_RISING_EDGE, extts_polarity_enu),
PORT_ITEM_INT("ts2phc.master", 0, 0, 1),
PORT_ITEM_INT("ts2phc.nmea_baudrate", 9600, 300, INT_MAX),
GLOB_ITEM_STR("ts2phc.nmea_remote_host", ""),
GLOB_ITEM_STR("ts2phc.nmea_remote_port", ""),
GLOB_ITEM_STR("ts2phc.nmea_serialport", "/dev/ttyS0"),
Expand Down
23 changes: 12 additions & 11 deletions ts2phc.8
Original file line number Diff line number Diff line change
Expand Up @@ -146,19 +146,20 @@ set to 0.0, the servo will never step the clock except on start.
The default is 0.0.
.TP
.B ts2phc.nmea_remote_host, ts2phc.nmea_remote_port
Specifies the serial port character device providing ToD information
when using the "nmea" PPS signal source. Note that if these two
options are both specified, then the given remote connection will be
used in preference to the configured serial port.
These options default to the empty string, that is, not specified.
.TP
.B ts2phc.nmea_serialport
Specifies the serial port character device providing ToD information
when using the "nmea" PPS signal source. Note that if the options,
ts2phc.nmea_remote_host and ts2phc.nmea_remote_port, are both
Specifies the remote host providing ToD information when using the
"nmea" PPS signal source. Note that if these two options are both
specified, then the given remote connection will be used in preference
to the configured serial port.
The default is "/dev/ttyS0".
These options default to the empty string, that is, not specified.
.TP
.B ts2phc.nmea_serialport, ts2phc.nmea_baudrate
Specifies the serial port and baudrate in bps for character device
providing ToD information when using the "nmea" PPS signal source. Note
that if the options, ts2phc.nmea_remote_host and
ts2phc.nmea_remote_port, are both specified, then the given remote
connection will be used in preference to the configured serial port.
The default serial port is "/dev/ttyS0".
The default baudrate is 9600 bps.
.TP
.B ts2phc.pulsewidth
The expected pulse width of the external PPS signal in nanoseconds.
Expand Down
10 changes: 5 additions & 5 deletions ts2phc_nmea_master.c
Original file line number Diff line number Diff line change
Expand Up @@ -23,7 +23,6 @@
#include "ts2phc_nmea_master.h"
#include "util.h"

#define BAUD 9600
#define MAX_RMC_AGE 5000000000ULL
#define NMEA_TMO 2000 /*milliseconds*/

Expand All @@ -45,7 +44,7 @@ struct ts2phc_nmea_master {
};

static int open_nmea_connection(const char *host, const char *port,
const char *serialport)
const char *serialport, int baud)
{
int fd;

Expand All @@ -56,7 +55,7 @@ static int open_nmea_connection(const char *host, const char *port,
}
return fd;
}
fd = serial_open(serialport, BAUD, 0, 0);
fd = serial_open(serialport, baud, 0, 0);
if (fd == -1) {
pr_err("failed to open nmea source %s", serialport);
}
Expand All @@ -70,7 +69,7 @@ static void *monitor_nmea_status(void *arg)
char *host, input[256], *port, *ptr, *uart;
struct ts2phc_nmea_master *master = arg;
struct timespec rxtime, tmo = { 2, 0 };
int cnt, num, parsed;
int cnt, num, parsed, baud;
struct nmea_rmc rmc;
struct timex ntx;

Expand All @@ -81,12 +80,13 @@ static void *monitor_nmea_status(void *arg)
host = config_get_string(master->config, NULL, "ts2phc.nmea_remote_host");
port = config_get_string(master->config, NULL, "ts2phc.nmea_remote_port");
uart = config_get_string(master->config, NULL, "ts2phc.nmea_serialport");
baud = config_get_int(master->config, NULL, "ts2phc.nmea_baudrate");
memset(&ntx, 0, sizeof(ntx));
ntx.modes = ADJ_NANO;

while (is_running()) {
if (pfd.fd == -1) {
pfd.fd = open_nmea_connection(host, port, uart);
pfd.fd = open_nmea_connection(host, port, uart, baud);
if (pfd.fd == -1) {
clock_nanosleep(CLOCK_MONOTONIC, 0, &tmo, NULL);
continue;
Expand Down