Homebridge Plugin providing data from Nibe Uplink

License

Notifications You must be signed in to change notification settings

zlugg/homebridge-nibe

 
 

Repository files navigation

homebridge-nibe

NPM version Release GitHub license Downloads

Build status

NPM

Nibeuplink plugin for homebridge

This homebridge plugin retrieves data from a Nibe heat pump from Nibe Uplink.

Plugin configuration

Whole setup instruction is available on plugin configuration page in homebridge. There is step by step description how to get required parameters.

Supported devices and accessories

Device list

  • F370 CU 3x400V
  • F470 CU 3x400V
  • F730 CU 3x400V
  • F750 CU 3x400V
  • F750 E EM 3x400V
  • F1145-10 PC
  • F1245-6 E PC EM
  • F1245-6 R
  • F1255-6 E EM
  • F1255-6 R PC EM 3x400V
  • F2040
  • F2120-12
  • SMO 40
  • VVM 500
  • VVM 320 E

If your device is not on the list please install the plugin, configure it and you will see error log in homebridge with details how to create "add new device" issue

Accessory Description Device
outdoor-temperature BT1 outdoor temperature (40004 or 44362)
  • F370 CU 3x400V - v0.0.14
  • F470 CU 3x400V - v0.0.20
  • F730 CU 3x400V - v0.0.19
  • F750 CU 3x400V - v0.0.14
  • F750 E EM 3x400V - v0.1.2
  • F1145-10 PC - v0.0.14
  • F1245-6 E PC EM - v0.0.14
  • F1245-6 R - v0.0.20
  • F1255-6 E EM - v0.0.15
  • F1255-6 R PC EM 3x400V - v0.0.16
  • F2040-12 - v0.0.14
  • F2120-12 - v0.0.14
  • SMO 40 - v0.0.16
  • VVM 320 E - v0.0.14
  • VVM 500 - v0.0.14
average-outdoor-temperature BT1 average outdoor temperature (40067)
  • F370 CU 3x400V - v0.0.16
  • F470 CU 3x400V - v0.0.20
  • F730 CU 3x400V - v0.0.19
  • F750 CU 3x400V - v0.0.16
  • F750 E EM 3x400V - v0.1.2
  • F1145-10 PC - v0.0.16
  • F1245-6 E PC EM - v0.0.16
  • F1245-6 R - v0.0.20
  • F1255-6 E EM - v0.0.16
  • F1255-6 R PC EM 3x400V - v0.0.16
  • F2120-12 - v0.0.16
  • SMO 40 - v0.0.16
  • VVM 320 E - v0.0.16
  • VVM 500 - v0.0.16
hot-water Hot water temperature (40014) with temporary lux on activation (48132)
  • F370 CU 3x400V - v0.0.14
  • F470 CU 3x400V - v0.0.20
  • F730 CU 3x400V - v0.0.19
  • F750 CU 3x400V - v0.0.14
  • F750 E EM 3x400V - v0.1.2
  • F1145-10 PC - v0.0.14
  • F1245-6 E PC EM - v0.0.14
  • F1245-6 R - v0.0.20
  • F1255-6 E EM - v0.0.15
  • F1255-6 R PC EM 3x400V - v0.0.16
  • SMO 40 - v0.0.16
  • VVM 320 E - v0.0.14
  • VVM 500 - v0.0.14
hot-water-top Top hot water temperature (40013)
  • F370 CU 3x400V - v0.0.16
  • F470 CU 3x400V - v0.0.20
  • F730 CU 3x400V - v0.0.19
  • F750 CU 3x400V - v0.0.16
  • F750 E EM 3x400V - v0.1.2
  • F1245-6 E PC EM - v0.0.16
  • F1245-6 R - v0.0.20
  • F1255-6 E EM - v0.0.16
  • F1255-6 R PC EM 3x400V - v0.0.16
  • SMO 40 - v0.0.16
  • VVM 320 E - v0.0.16
  • VVM 500 - v0.0.16
ers-exhaust-air ERS exhaust air temperature (40025). ERS accessory is needed.
  • F1145-10 PC - v0.1.0
  • F1255-6 R PC EM 3x400V - v0.1.0
  • SMO 40 - v0.1.0
ers-extract-air ERS extract air temperature (40026). ERS accessory is needed.
  • F1145-10 PC - v0.1.0
  • F1255-6 R PC EM 3x400V - v0.1.0
  • SMO 40 - v0.1.0
ers-supply-air ERS supply air temperature (40075). ERS accessory is needed.
  • F1145-10 PC - v0.1.0
  • F1255-6 R PC EM 3x400V - v0.1.0
  • SMO 40 - v0.1.0
ers-outdoor ERS outdoor temperature (40183). ERS accessory is needed.
  • F1145-10 PC - v0.1.0
  • F1255-6 R PC EM 3x400V - v0.1.0
  • SMO 40 - v0.1.0
ers-fan ERS fan speed (40311, 40312) with change rotation speed (47260). ERS accessory is needed.
  • F1145-10 PC - v0.1.0
  • F1255-6 E EM - v0.1.0
  • SMO 40 - v0.1.0

Roadmap

https://github.com/hp-net/homebridge-nibe/projects/1

Configuration

Whole configuration can be done via homebridge ui and this is recommended way to do it.

However, you can also make all changes directly in homebridge config.json file. Below you can find description of all options.

Name Required Default Description
platform Yes Nibe 'Nibe' is only correct value. If value will be different configuration will not match plugin.
identifier Yes Api app identifier from Nibe Uplink account. Read instructions from plugin configuration to know how to get it.
secret Yes Api app secret from Nibe Uplink account. Read instructions from plugin configuration to know how to get it.
authCode Yes Authorization code for the app from Nibe Uplink. Read instructions from plugin configuration to know how to get it.
systemIdentifier Yes System identifier for installed Nibe devices.
callbackUrl Yes https://hp-net.github.io/homebridge-nibe/nibe.html Url that will handle callback with authCode parameter. Default page is safe, it does not have any tracking scrips or additional logic to do weird stuff with the code. What is more authCode is not enough to da anything with api. Default page will only show you the code and give you a nice button to copy it to clipboard.
language No en Language to call Nibe Uplink Api and to set accessories labels. Possible values: 'en', 'pl'.
pollingPeriod No 60 Period (in seconds) for fetching device changes from api.
disabledAccessories No List of accessories to disable. Format 'id(name)' or 'id'.
ersStep0, ersStep1, ersStep2, ersStep3, ersStep4 No 65, 0, 30, 80, 100 ERS steps configured for your heat pomp. If values are not set correctly then changing ERS fan speed will not work.