Skip to content

This repository is used for automatic calibration between high resolution LiDAR and camera in targetless scenes.

License

Notifications You must be signed in to change notification settings

coolaogege/livox_camera_calib

 
 

Folders and files

NameName
Last commit message
Last commit date

Latest commit

 

History

33 Commits
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Repository files navigation

lidar_camera_calib

lidar_camera_calib is a robust, high accuracy extrinsic calibration tool between high resolution LiDAR (e.g. Livox) and camera in targetless environment. Our algorithm can run in both indoor and outdoor scenes, and only requires edge information in the scene. If the scene is suitable, we can achieve pixel-level accuracy similar to or even beyond the target based method.

An example of a outdoor calibration scenario. We color the point cloud with the calibrated extrinsic and compare with actual image. A and C are locally enlarged views of the point cloud. B and D are parts of the camera image corresponding to point cloud in A and C.

Info

New features:

  1. Support muti-scenes calibration (more accurate and robust)

Related paper

Related paper available on arxiv:
Pixel-level Extrinsic Self Calibration of High Resolution LiDAR and Camera in Targetless Environments

Related video

Related video: https://youtu.be/e6Vkkasc4JI

1. Prerequisites

1.1 Ubuntu and ROS

Ubuntu 64-bit 16.04 or 18.04. ROS Kinetic or Melodic. ROS Installation and its additional ROS pacakge:

    sudo apt-get install ros-XXX-cv-bridge ros-xxx-pcl-conversions

1.2 Eigen

Follow Eigen Installation

1.3 Ceres Solver

Follow Ceres Installation.

1.4 PCL

Follow PCL Installation. (Our code is tested with PCL1.7)

2. Build

Clone the repository and catkin_make:

cd ~/catkin_ws/src
git clone https://github.com/hku-mars/livox_camera_calib.git
cd ../
catkin_make
source ~/catkin_ws/devel/setup.bash

3. Run our example

3.1 Single scene calibration

Download Our pcd and iamge file to your local path, and then change the file path in calib.yaml to your data path. Then directly run

roslaunch livox_camera_calib calib.launch

You will get the following result. (Sensor suite: Livox Avia + Realsense-D435i)

An example of single scene calibration.

3.2 Multi scenes calibration

Download Our pcd and iamge file to your local path, and then change the file path in multi_calib.yaml to your data path. Then directly run

roslaunch livox_camera_calib multi_calib.launch

The projected images obtained by initial extrinsic parameters. (Sensor Suite: Livox Horizon + MVS camera)

An example of multi scenes calibration. The projected image obtained by theinitial extrinsic parameters
Rough calibration is used to deal with the bad extrinsic.
The projected image obtained by the extrinsic parameters after rough calibration
Then we finally get a fine extrinsic after final optimization.
The projected image obtained by the extrinsic parameters after fine calibration

4. Run on your own sensor set

4.1 Record data

Record the point cloud to pcd files and record image files.

4.2 Modify the calib.yaml

Change the data path to your local data path.
Provide the instrinsic matrix and distor coeffs for your camera.

4.3 Use multi scenes calibration

Change the params in multi_calib.yaml, name the image file and pcd file from 0 to (data_num-1).

About

This repository is used for automatic calibration between high resolution LiDAR and camera in targetless scenes.

Resources

License

Stars

Watchers

Forks

Releases

No releases published

Packages

No packages published

Languages

  • C++ 98.7%
  • CMake 1.3%